Journals / Cardiovascular surgery and interventions / 2021 / Cilt: 8 - Sayı: 2

Comparison of electrocautery and LigaSure™ vessel sealing system in radial arteryharvesting as coronary artery bypass surgery conduit: A prospective, randomized study

Pages
98–102
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Our study results suggest that the LigaSure™ vessel sealing system is a better option of RA harvesting, particularly inpatients who are prone to bleed.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: In this study, we aimed to compare the efficiency of electrocautery with the LigaSure™ vessel sealing system.
📊
Key Findings & Data:Patients and methods: This randomized study included a total of 53 patients (44 males, 9 females; mean age: 63.7±8.4 years;range, 39 to 83 years) who underwent coronary artery bypass grafting (CABG) for radial artery (RA) harvesting with electrocauteryor LigaSure™ vessel sealing system between January 2019 and September 2019.
💡
Conclusion & Impact:Conclusion: Our study results suggest that the LigaSure™ vessel sealing system is a better option of RA harvesting, particularly inpatients who are prone to bleed.
🔬Design:Research Article
📍Scope:2019 Verileri
⚙️Variables:Domain Parameters

Abstract

Objectives: In this study, we aimed to compare the efficiency of electrocautery with the LigaSure™ vessel sealing system. Patients and methods: This randomized study included a total of 53 patients (44 males, 9 females; mean age: 63.7±8.4 years;range, 39 to 83 years) who underwent coronary artery bypass grafting (CABG) for radial artery (RA) harvesting with electrocauteryor LigaSure™ vessel sealing system between January 2019 and September 2019. The patients were randomly assigned into two groups.Group 1 consisted of 27 patients operated with the LigaSure™ small jaw sealer/divider and Group 2 consisted of 26 patients operated withelectrocautery. The length of the conduit, the amount of intraoperative blood loss, the number of hemostatic clips before and after theanastomosis, the amount of postoperative blood loss, the number of ecchymoses, hematoma and infection are compared. Results: The amount of blood loss from the beginning of harvesting to the end of the closure of the skin of left arm was significantlylower in Group 1 (p=0.004). The difference in the number of hemostatic clips before and after the anastomosis of RA to coronary arterywas statistically significantly lower in Group 1 (p0.1), and postoperative hematoma (p>0.1) and infection (p>0.03)between the groups. Conclusion: Our study results suggest that the LigaSure™ vessel sealing system is a better option of RA harvesting, particularly inpatients who are prone to bleed.

🔖

Cite This Article

ŞENAY, Ş., ÖKTEN, M., OKUR, B., AKBABA, M., KARABULUT, H. (2022). Comparison of electrocautery and LigaSure™ vessel sealing system in radial arteryharvesting as coronary artery bypass surgery conduit: A prospective, randomized study. Cardiovascular surgery and interventions, Cilt: 8 - Sayı: 2, 98–102. https://ajindex.com/articles/471103

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Baikoussis NG, Papakonstantinou NA, Apostolakis E. Radial artery as graft for coronary artery bypass surgery: Advantages and disadvantages for its usage focused on structural and biological characteristics. J Cardiol 2014;63:321-8
  2. Ashraf T, Panhwar Z, Habib S, Memon MA, Shamsi F, Arif J. Size of radial and ulnar artery in local population. J Pak Med Assoc 2010;60:817-9
  3. Verma S, Szmitko PE, Weisel RD, Bonneau D, Latter D, Errett L, et al. Should radial arteries be used routinely for coronary artery bypass grafting? Circulation 2004;110:e40-6
  4. Ignjatović M, Kostić Z. Thyroidectomy with LigaSure. Surg Today 2011;41:767-73
  5. Colella G, Giudice A, Vicidomini A, Sperlongano P. Usefulness of the LigaSure vessel sealing system during superficial lobectomy of the parotid gland. Arch Otolaryngol Head Neck Surg 2005;131:413-6
  6. Brazio PS, Laird PC, Xu C, Gu J, Burris NS, Brown EN, et al. Harmonic scalpel versus electrocautery for harvest of radial artery conduits: Reduced risk of spasm and intimal injury on optical coherence tomography. J Thorac Cardiovasc Surg 2008;136:1302-8
  7. Uysal D, Gülmen Ş, Özkan H, Sağlam U, Etli M, Bircan S, et al. Comparison of sharp dissection, electrocautery, and ultrasonic activated scalpel with regard to endothelial damage, preparation time, and postoperative bleeding during radial artery harvesting. Braz J Cardiovasc Surg 2019;34:667-73
  8. Bhettani MK, Rehman M, Khan MS, Altaf HN, Hakeem Khan K, Farooqui F, et al. Safety and cost-effectiveness of LigaSure® in total thyroidectomy in comparison with conventional suture tie technique. Cureus 2019;11:e6368
  9. Lauroy A, Verhaeghe C, Vidal F, Parant O, Legendre G, Guerby P. Perioperative outcomes using LigaSure compared with conventional technique in peripartum hysterectomy. Arch Gynecol Obstet 2020;301:229-34
  10. Levine NL, Zhang Y, Hoang BH, Yang R, Jurkowski ZH, Roth ME, et al. LigaSure use decreases intraoperative blood loss volume and blood transfusion volume in sarcoma surgery. J Am Acad Orthop Surg 2019;27:841-7
  11. Shimizu Y, Watanabe G, Tomita S, Matsumoto I, Iino K. A novel technique for harvesting the internal thoracic artery: Linear harvesting technique using an ultrasonic surgical aspirator. Interact Cardiovasc Thorac Surg 2011;12:998-1001
  12. Dutta DK, Dutta I. The harmonic scalpel. J Obstet Gynaecol India 2016;66:209-10
  13. Kieser TM, Rose MS, Aluthman U, Narine K. Quicker yet safe: Skeletonization of 1640 internal mammary arteries with harmonic techn