While there was a positive correlation between computer-assisted joint space area measurement and other quantitative measurements, there was a negative correlation between computer-assisted joint space area measurement and whole-organ magnetic resonance imaging scores.Conclusion: When compared with qualitative, quantitative, and semi-quantitative methods, computer-assisted joint space area measurement seems to be a useful, reproducible, and cost-effective quantitative method for evaluating knee osteoarthritis.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: This study aims to assess the validity and reproducibility of computer-assisted joint space area measurement in knee roentgenograms of patients with knee osteoarthritis and compare it with a qualitative method in knee roentgenograms and quantitative and semi-quantitative methods in magnetic resonance imaging.Patients and methods: The study included 40 knees of 40 patients diagnosed as osteoarthritis (14 males, 26 females; mean age 57.4±5.9 years; range 47 to 67 years).
📊
Key Findings & Data:Interobserver consistency was evaluated by comparing the measurements of two blinded physicians and no differences were found (p>0.05).
💡
Conclusion & Impact:While there was a positive correlation between computer-assisted joint space area measurement and other quantitative measurements, there was a negative correlation between computer-assisted joint space area measurement and whole-organ magnetic resonance imaging scores.Conclusion: When compared with qualitative, quantitative, and semi-quantitative methods, computer-assisted joint space area measurement seems to be a useful, reproducible, and cost-effective quantitative method for evaluating knee osteoarthritis.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objectives: This study aims to assess the validity and reproducibility of computer-assisted joint space area measurement in knee roentgenograms of patients with knee osteoarthritis and compare it with a qualitative method in knee roentgenograms and quantitative and semi-quantitative methods in magnetic resonance imaging.Patients and methods: The study included 40 knees of 40 patients diagnosed as osteoarthritis (14 males, 26 females; mean age 57.4±5.9 years; range 47 to 67 years). Only the patients who wrote consents for publication of their radiologic data, and with knee roentgenograms and magnetic resonance images of the same knees were selected. Computer-assisted measurements were applied to joint spaces by two blinded physicians, for two times with an interval of one week. Data were evaluated for intraobserver and interobserver consistency. Also, data were compared with qualitative (Kellgren-Lawrence classification), quantitative (joint space width, cartilage thickness, meniscal thickness in magnetic resonance images) and semi-quantitative methods (whole-organ magnetic resonance imaging score).Results: Intraobserver consistency was evaluated for each physician, which revealed no differences. Interobserver consistency was evaluated by comparing the measurements of two blinded physicians and no differences were found (p>0.05). There was no significant correlation between the grade of Kellgren-Lawrence classification and other variables; such as grade of meniscus, meniscal thickness, cartilage thickness and computerassisted joint space area measurements (p>0.05). While there was a positive correlation between computer-assisted joint space area measurement and other quantitative measurements, there was a negative correlation between computer-assisted joint space area measurement and whole-organ magnetic resonance imaging scores.Conclusion: When compared with qualitative, quantitative, and semi-quantitative methods, computer-assisted joint space area measurement seems to be a useful, reproducible, and cost-effective quantitative method for evaluating knee osteoarthritis.

🔖

Cite This Article

TOSUN, A., ÇELİK, C., AVCI, E., GÜDER, N., İLHANLI, İ. (2022). Computer-Assisted Joint Space Area Measurement: A New Technique in Patients With Knee Osteoarthritis. Archives of Rheumatology, Cilt: 32 - Sayı: 4, 339–346. https://ajindex.com/articles/448031

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Peat G, Thomas E, Duncan R, Wood L, Hay E, Croft P. Clinical classification criteria for knee osteoarthritis: performance in the general population and primary care. Ann Rheum Dis 2006;65:1363-7
  2. Kellgren JH, Lawrence JS. Radiological assessment of osteo-arthrosis. Ann Rheum Dis 1957;16:494-502
  3. Peterfy CG, Guermazi A, Zaim S, Tirman PF, Miaux Y, White D, et al. Whole-Organ Magnetic Resonance Imaging Score (WORMS) of the knee in osteoarthritis. Osteoarthritis Cartilage 2004;12:177-90
  4. Peterfy CG, van Dijke CF, Janzen DL, Glüer CC, Namba R, Majumdar S, et al. Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation. Radiology 1994;192:485-91
  5. Pilch L, Stewart C, Gordon D, Inman R, Parsons K, Pataki I, et al. Assessment of cartilage volume in the femorotibial joint with magnetic resonance imaging and 3D computer reconstruction. J Rheumatol 1994;21:2307-21
  6. Eckstein F, Sitteck H, Gavazzenia A, Milz S, Putz R, Reiser M. Assessment of articular cartilage volume and thickness with magnetic resonance imaging (MRI). Trans Orthop Res Soc 1995;20:194
  7. Eckstein F, Winzheimer M, Hohe J, Englmeier KH, Reiser M. Interindividual variability and correlation among morphological parameters of knee joint cartilage plates: analysis with three-dimensional MR imaging. Osteoarthritis Cartilage 2001;9:101-11
  8. Cicuttini F, Forbes A, Asbeutah A, Morris K, Stuckey S. Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume. J Orthop Res 2000;18:580-4
  9. Glaser C, Faber S, Eckstein F, Fischer H, Springer V, Heudorfer L, et al. Optimization and validation of a rapid high-resolution T1-w 3D FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness. Magn Reson Imaging 2001;19:177-85
  10. Nishii T, Shiomi T, Sakai T, Takao M, Yoshikawa H, Sugano N. Computational measurement of joint space width and structural parameters in normal hips. Arch Orthop Trauma Surg 2012;132:591-8
  11. Boegård TL, Rudling O, Petersson IF, Jonsson K. Joint space width of the tibiofemoral and of the patellofemoral joint in chronic knee pain with or without radiographic osteoarthritis: a 2-year followup. Osteoarthritis Cartilage 2003;11:370-6
  12. Vignon E, Conrozier T, Hellio Le Graverand MP. Advances in radiographic imaging of progression of hip