Objective & Hypothesis:Aim: To compare the cyclic fatigue resistance at distilled water and %5.25 NaOCl of immersed ProTaper Gold (Dentsply Sirona,Ballaigues, Switzerland) and ProTaper Universal (Dentsply Sirona, Ballaigues, Switzerland) file systems.Material and Methods: The ProTaper Gold F2 (25.06v taper) and ProTaper Universal F2 (25.06v taper) file systems were immersedin distilled water andNaOCl for 5 minutes.
📊
Key Findings & Data:After immersion process files were rotated at artificial canal with 60O curvature and a5-mm radius until fracture occurred.
💡
Conclusion & Impact:Statistical significance was set at P
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters
Abstract
Aim: To compare the cyclic fatigue resistance at distilled water and %5.25 NaOCl of immersed ProTaper Gold (Dentsply Sirona,Ballaigues, Switzerland) and ProTaper Universal (Dentsply Sirona, Ballaigues, Switzerland) file systems.Material and Methods: The ProTaper Gold F2 (25.06v taper) and ProTaper Universal F2 (25.06v taper) file systems were immersedin distilled water andNaOCl for 5 minutes. After immersion process files were rotated at artificial canal with 60O curvature and a5-mm radius until fracture occurred. Time to fracture and fractured lengths were recorded. Data were analyzed statistically usingindependent t-tests. Statistical significance was set at P
🔖
Cite This Article
ERTUĞRUL, İ. F. (2022). Effect of NaOCl solution on the cyclic fatigue resistance of traditional and heat-treated file systems. Annals of Medical Research, Cilt: 26 - Sayı: 9, 1761–1763. https://ajindex.com/articles/446789
Cheung GS, Liu CS. A retrospective study of endodontic treatment outcome between nickel titanium rotary and stainless steel hand filing techniques. J Endod 2009;35:938- 43
Iqbal MK, Kohli MR, Kim JS. A retrospective clinical study of incidence of root canal instrument separation in an endodontics graduate program: a PennEndo database study. J Endod 2006;32:1048-52
Sattapan B, Nervo GJ, Palamara JE, et al. Defects in rotary nickel-titanium files after clinical use. J Endod 2000;26:161- 5
Shen Y, Zhou H-m, Zheng Y-f, et al. Current challenges and concepts of the thermomechanical treatment of nickeltitanium instruments. J Endod 2013;39:163-72
Gutmann J, Gao Y. Alteration in the inherent metallic and surface properties of nickel–titanium root canal instruments to enhance performance, durability and safety: a focused review. Int Endod J 2012;45:113-28
Gambarini G, Grande NM, Plotino G, et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 2008;34:1003-5
Bardsley S, Peters CI, Peters OA. The effect of three rotational speed settings on torque and apical force with vortex rotary instruments in vitro. J Endod 2011;37:860-4
Hieawy A, Haapasalo M, Zhou H, et al. Phase Transformation Behavior and Resistance to Bending and Cyclic Fatigue of ProTaper Gold and ProTaper Universal Instruments. J Endod 2015;41:1134-8
Clarkson RM, Moule AJ. Sodium hypochlorite and its use as an endodontic irrigant. Aust Dent J 1998;43:250-6
Mohammadi Z. Sodium hypochlorite in endodontics: an update review. Int Dent J 2008;58:329-41
Busslinger A, Sener B, Barbakow F. Effects of sodium hypochlorite on nickel-titanium Lightspeed instruments. Int Endod J 1998;31:290-4
Berutti E, Angelini E, Rigolone M, et al. Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. Int Endod J 2006;39:693-9
O’hoy P, Messer H, Palamara J. The effect of cleaning procedures on fracture properties and corrosion of NiTi files. Int Endod J 2003;36:724-32
Pedullà E, Grande NM, Plotino G, et al. Cyclic fatigue resistance of three different nickel-titanium instruments after immersion in sodium hypochlorite. J Endod 2011;37:1139-42
Keles A, Ozyurek EU, Uyanik MO, et al. Effect of Temperature of Sodium Hypochlorite on Cyclic Fatigue Resistance of Heat-treated Reciprocating Files. J Endod 2019; 45: 205-8. 16