Journals / Annals of Medical Research / 2021 / Cilt: 28 - Sayı: 4

The role of acoustic radiation force impulse imaging in thediagnosis of cervical carcinoma

Pages
733–737
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Acoustic radiation force impulse imaging is a non-invasive and cost-effective, promising adjunct modality that enablesobjective quantitative measurement, which may contribute to the diagnosis of malignant cervical masses.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: To investigate the diagnostic value of acoustic radiation force impulse imaging in the detection of cervical cancer, and toassess the contribution of this imaging method in distinguishing histological subtypes of cervical carcinoma.
📊
Key Findings & Data:Materials and Methods: Twenty four patients with malignant cervical mass and 25 healthy volunteers were included in this prospectivestudy.
💡
Conclusion & Impact:Conclusion: Acoustic radiation force impulse imaging is a non-invasive and cost-effective, promising adjunct modality that enablesobjective quantitative measurement, which may contribute to the diagnosis of malignant cervical masses.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Aim: To investigate the diagnostic value of acoustic radiation force impulse imaging in the detection of cervical cancer, and toassess the contribution of this imaging method in distinguishing histological subtypes of cervical carcinoma. Materials and Methods: Twenty four patients with malignant cervical mass and 25 healthy volunteers were included in this prospectivestudy. Ultrasonographic evaluation were performed using a 3.5–6-MHz convex abdominal transducer and adequate software forperforming elastographic examinations in quantitative acoustic radiation force impulse mode (Virtual Touch Quantification®). Everyexamination consisted of at least three independent shear wave velocity measurements. The mean shear wave velocity values werecalculated, and used for statistical analysis. Postoperative pathology results of the lesions were used as the reference standard. Results: The mean shear wave velocity values were calculated as 2.79±1.03 m/s in cervical carcinomas, and as 1.86±0.62 m/s incontrol group. The mean shear wave velocity value of cervical carcinomas was significantly higher than the control group (p=0.003).The mean shear wave velocity values in squamous carcinoma, adenocarcinoma, and adenosquamous carcinoma subtypes werecalculated as 2.78±0.93 m/s, 3.16±1.46 m/s, and 1.90±0.21 m/s, respectively. There were no significant differences between cervicalcarcinoma subtypes in terms of their shear wave velocity values (p=0.247). Conclusion: Acoustic radiation force impulse imaging is a non-invasive and cost-effective, promising adjunct modality that enablesobjective quantitative measurement, which may contribute to the diagnosis of malignant cervical masses.

🔖

Cite This Article

AYHAN, A., ÇOLAK, M. Y., TURNAOĞLU, H., REYHAN, A. N. H., KARAKAŞ, L. A., HABERAL, K. M. (2022). The role of acoustic radiation force impulse imaging in thediagnosis of cervical carcinoma. Annals of Medical Research, Cilt: 28 - Sayı: 4, 733–737. https://ajindex.com/articles/446012

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Ferlay J, Colombet M, Soerjomataram I, et al. Estimating the global cancer incidence and mortality in 2018: GLOBOCAN sources and methods. Int J Cancer 2019;144:1941-53
  2. Katanyoo K, Sanguanrungsirikul S, Manusirivithaya S. Comparison of treatment outcomes between squamous cell carcinoma and adenocarcinoma in locally advanced cervical cancer. Gynecol Oncol 2012;125:292-6
  3. Fischerova D, Cibula D, Stenhova H, et al. Transrectal ultrasound and magnetic resonance imaging in staging of early cervical cancer. Int J Gynecol Cancer 2008;18:766-72
  4. Mainenti PP, Pizzuti LM, Segreto S, et al. Diffusion volume (DV) measurement in endometrial and cervical cancer: a new MRI parameter in the evaluation of the tumor grading and the risk classification. Eur J Radiol 2016;85:113-24
  5. Kuang F, Ren J, Zhong Q, et al. The value of apparent diffusion coefficient in the assessment of cervical cancer. Eur Radiol 2013;23:1050-8
  6. Liu Y, Ye Z, Sun H, et al. Grading of uterine cervical cancer by using the ADC difference value and its correlation with microvascular density and vascular endothelial growth factor. Eur Radiol 2013;23:757-65
  7. Su Y, Du L, Wu Y, al. Evaluation of cervical cancer detection with acoustic radiation force impulse ultrasound imaging. Exp Ther Med 2013;5:1715-9
  8. Sporea I, Sirli R, Popescu A, et al. Acoustic Radiation Force Impulse (ARFI)-a new modality for the evaluation of liver fibrosis. Med Ultrason 2010;12:26-31
  9. Samier-Guérin A, Saraux A, Gestin S, et al. Can ARFI elastometry of the salivary glands contribute to the diagnosis of Sjögren's syndrome? Joint Bone Spine 2016;83:301-6
  10. Matsuzuka T, Suzuki M, Saijo S, et al. Stiffness of salivary gland and tumor measured by new ultrasonic techniques: Virtual touch quantification and IQ. Auris Nasus Larynx 2015;42:128-33
  11. Barr RG. Elastography in clinical practice. Radiol Clin North Am 2014;52:1145-1162
  12. D’Onofrio M, Crosara S, De Robertis R, et al. Acoustic radiation force impulse of the liver. World J Gastroenterol 2013;19:4841-9
  13. Sporea I, Sirli R, Bota S, et al. ARFI elastography for the evaluation of diffuse thyroid gland pathology: Preliminary results. World J Radiol 2012;4:174-8
  14. Tozaki M, Isobe S, Sakamoto M. Combination of elastography and tissue quantification using the acoustic radiation force impulse (ARFI) technology for differential diagnosis of breast masses. Jpn J Radiol 2012;30:659-70
  15. Liu C, Li TT, Hu Z, et al. Transvaginal Real-time Shear Wave Elasto