Journals / Anestezi Dergisi / 2021 / Cilt: 29 - Sayı: 2

Estimation of Appropriate Endotracheal Tube Size in Pediatric Patients: Use of Epiphyseal Diameter of the Distal Radius and Subglottic Diameter

Pediyatrik Hastalarda Uygun Endotrakeal Tüp Çapının Belirlenmesi: Distal Radius Epifiz Çapının ve Subglottik Çapın Kullanımı

Pages
119–124
Publication Date
2022-10-10
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The correlation of the epiphysis diameter of the distal radius and best-fit ETT was significant (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study is to test the usefulness of epiphysis of distal radius measurement as a surrogate parameter for endotracheal tube (ETT) size prediction in children.
📊
Key Findings & Data:Results: First attempt success at intubation was 83.6%.
💡
Conclusion & Impact:The correlation of the epiphysis diameter of the distal radius and best-fit ETT was significant (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this study is to test the usefulness of epiphysis of distal radius measurement as a surrogate parameter for endotracheal tube (ETT) size prediction in children. Methods: Seventy-three children were intubated with cuffed ETT selected according to age-based formula. Transvers diameter of epiphysis of distal radius and subglottic diameter of trachea were measured by ultrasound (USG). Correlation between the outer diameter of best-fit endotracheal tube and transvers diameter of both radius epiphysis and subglottic diameter were calculated. The need for tube exchange, time for USG measurements and the ease level of measurements were compared. Results: First attempt success at intubation was 83.6%. The correlation of the epiphysis diameter of the distal radius and best-fit ETT was significant (p

Özet

Amaç: Bu çalışmanın amacı, çocuklarda endotrakeal tüp (ETT) çapının belirlenmesinde yedek parametre olarak distal radius epifiz ölçümünün yararlılığını test etmektir. Yöntem: Yetmiş üç çocuk, yaşa dayalı formüle göre seçilen kafli ETT ile entübe edildi. Distal radius epifizinin transvers çapı ve trakeanın subglotik çapı ultrason (USG) ile ölçüldü. En uygun endotra- keal tüpün iç çapı ile hem radius epifizi hem de subglottik çapın transvers çapı arasındaki ilişki hesaplandı. Tüp değiştirme ihtiyacı, USG ölçümleri için zaman ve ölçümlerin kolaylık düzeyi karşı- laştırıldı. Bulgular: Entübasyonda ilk girişim başarısı %83.6 idi. Distal radiusun epifiz çapı ile en iyi uyan ETT arasındaki korelasyon anlamlıydı (p

🔖

Cite This Article

Altun, D., Çamcı, E., Altun, D., Doruk, C., Dincer, M. B., Güler, M. M. (2022). Estimation of Appropriate Endotracheal Tube Size in Pediatric Patients: Use of Epiphyseal Diameter of the Distal Radius and Subglottic Diameter. Anestezi Dergisi, Cilt: 29 - Sayı: 2, 119–124. https://ajindex.com/articles/440426

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Cook TM, Macdougall-Davis SR. Complications and failure of airway management. Br J Anaesth. 2012;109:68-85. https://doi.org/10.1093/bja/aes393 2. von Rettberg M, Thil E, Genzwürker H, Gernoth C, Hinkelbein J. Endotrachealtuben bei Kindern. Publizierte Formeln zur Abschätzung der optimalen Grösse. Anaesthesist. 2011;60:334-42.
  2. Cole F. Pediatric Formulas for the Anesthesiologist. Arch Pediatr Adolesc Med. 1957;94:672.
  3. Khine HH, Corddry DH, Kettrick RG, et al. Comparison of cuffed and uncuffed endotracheal tubes in young children during general anesthesia. Anesthesiology. 1997;86:627-31.
  4. Motoyama E. Endotracheal Intubation. In: Davis P, Cladis F, Motoyama E, editors. Smith’s Anesth Infants Child 5th Editio. St Louis: CV Mosby. 1990; 269-75
  5. Sutagatti JG, Raja R, Kurdi MS. Ultrasonographic Estimation of Endotracheal Tube Size in Paediatric Patients and its Comparison with Physical Indices Based Formulae: A Prospective Study. J Clin Diagnostic Res. 2017;11:5-8.
  6. Shibasaki M, Nakajima Y, Ishii S, Shimizu F, Shime N, Sessler DI. Prediction of pediatric endotracheal tube size by ultrasonography. Anesthesiology. 2010;113:819- 24.
  7. Altun D, Orhan-Sungur M, Ali A, Özkan-Seyhan T, Sivrikoz N, Çamcı E. The role of ultrasound in appropriate endotracheal tube size selection in pediatric patients. von Ungern-Sternberg B, editor. Pediatr Anesth. 2017;27:1015-20.
  8. Singh S, Jindal P, Ramakrishnan P, Raghuvanshi S. Prediction of endotracheal tube size in children by predicting subglottic diameter using ultrasonographic measurement versus traditional formulas. Saudi J Anaesth. 2019;13:93-9
  9. King BR, Baker MD, Braitman LE, Seidl-Friedman J, Schreiner MS. Endotracheal tube selection in children: a comparison of four methods. Ann Emerg Med. 1993;22:530-4.
  10. Van Den Berg AA, Mphanza T. Choice of tracheal tube size for children: finger size or age-related formula? Anaesthesia. 1997;52:701-3.
  11. Kim HY, Cheon JH, Baek SH, Kim KH, Kim TK. Prediction of endotracheal tube size for pediatric patients from the epiphysis diameter of radius. Korean J Anesthesiol. 2017;70:52-7. https://doi.org/10.4097/kja