Journals / Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi / 2018 / Cilt: 18 - Sayı: 3

A New, Colorimetric and Fluorescent Chemosensor for The Selective Detection of Fe 2+ in Aqueous Media

Sulu Ortamda Fe +2 İyonlarını Seçici Olarak Tayin İçin Yeni Bir Kolorimetrik ve Floresan Kemosensör

Pages
796–806
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results obtained from UV-vis absorption and fluorescence experiments revealed that chemosensor C1 shows a good selectivity and sensitity to only Fe 2+ ions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Recently, colorimetric and fluorescent sensors providing advantages such as low cost, easy to use, high performance, unsophisticated, presentable as a test kit etc have attracted an important interest.
📊
Key Findings & Data:In this study, a new chemosensor based on a coumarine derivative was stynthesized and characterized by using Elemental analysis, Tandem mass, FT-IR, 1 H NMR and 13 C NMR spectroscopies.
💡
Conclusion & Impact:The results obtained from UV-vis absorption and fluorescence experiments revealed that chemosensor C1 shows a good selectivity and sensitity to only Fe 2+ ions.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Recently, colorimetric and fluorescent sensors providing advantages such as low cost, easy to use, high performance, unsophisticated, presentable as a test kit etc have attracted an important interest. In this study, a new chemosensor based on a coumarine derivative was stynthesized and characterized by using Elemental analysis, Tandem mass, FT-IR, 1 H NMR and 13 C NMR spectroscopies. After that, the selectivity and sensitivity behavior of chemosensor C1 towards biologically and environmentally important some metal ions was investigated in DMSO-H 2 O (v/v, 2:1) media. The results obtained from UV-vis absorption and fluorescence experiments revealed that chemosensor C1 shows a good selectivity and sensitity to only Fe 2+ ions.

Özet

Son zamanlarda, kolorimetrik ve floresan sensörler, sulu ortamdaki ağır ve geçiş metal iyonlarınınduyarlı ve seçici olarak tayin çalışmalarında düşük maliyet, kolay kullanım, yüksek performans, karmaşıkolmayışı, test kiti olarak hazırlanma gibi avantajlar sağladıkları için önemli derecede ilgi çekmiştir. Buçalışmada, kumarin temelli yeni bir kemosensör sentezlenmiş ve elementel analiz, FT-IR, Tandem kütle,1 H NMR ve 13 C NMR spektroskopileri kullanılarak karakterize edilmiştir. Daha sonra, sensör C1’inseçicilik ve duyarlılık özelliği, biyolojik ve çevresel açıdan öneme sahip bazı metal iyonlarına karşı DMSO-H 2 O (v/v, 2:1) ortamında araştırılmıştır. UV-vis absorpsiyon ve floresan deneylerinden elde edilensonuçlar, kemosensör C1’in sadece demir (II) iyonlarına yönelik seçicilik ve duyarlılık gösterdiğini ortayaçıkarmıştır.

🔖

Cite This Article

ÖZDEMİR, M. (2022). A New, Colorimetric and Fluorescent Chemosensor for The Selective Detection of Fe 2+ in Aqueous Media. Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi, Cilt: 18 - Sayı: 3, 796–806. https://ajindex.com/articles/429961

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Altural, B., Akcamur, Y., Saripinar, E., Yildirim, I.&Kollenz, G., 1989. Reactions of cyclic oxalyl compounds, part 29: A simple synthesis of functionalized 1H- pyrimidines. Monatshefte für Chemie/Chemical Monthly,120, 1015-1020.
  2. Chen, G.F., Jia, H.M., Zhang, L.Y., Hu, J., Chen, B.H., Song, Y.L.&Bai, G.Y., 2013. A highly selective fluorescent sensor for Fe 3+ ion based on coumarin derivatives. Research on Chemical Intermediates,39, 4081-4090.
  3. En, D., Guo, Y., Chen, B.T., Dong, B.&Peng, M.J., 2014. Coumarin-derived Fe 3+ -selective fluorescent turn-off chemosensors: synthesis, properties, and applications in living cells. RSC Advances, 4, 248-253. García-Beltrán, O., Mena, N., Yañez, O., Caballero, J., Vargas, V., Nuñez, M.T.&Cassels, B.K., 2013. Design, synthesis and cellular dynamics studies in membranes of a new coumarin-based “turn- off” fluorescent probe selective for Fe 2+. European journal of medicinal chemistry, 67, 60-63.
  4. Goswami, S., Sen, D., Das, A.K., Das, N.K., Aich, K., Fun, H.K., Quah, C.K., Maity, A.K.&Saha, P., 2013. A new rhodamine-coumarin Cu 2+-selective colorimetric and ‘off–on’fluorescence probe for effective use in chemistry and bioimaging along with its bound X-ray crystal structure. Sensors and Actuators B: Chemical,183, 518-525.
  5. Gupta, V.K., Singh, A.K., Ganjali, M.R., Norouzi, P., Faridbod, F.&Mergu, N., 2013. Comparative study of colorimetric sensors based on newly synthesized Schiff bases. Sensors and Actuators B: Chemical, 18, 642-651.
  6. He, G., Li, J., Wang, Z., Liu, C., Liu, X., Ji, L.&Wang, Q., 2017. Synthesis of a fluorogenic probe for thiols based on a coumarin schiff base copper complex and its use for the detection of glutathione. Tetrahedron,73, 272-277.
  7. Helal, A., Rashid, M.H.O., Choi, C.H.&Kim, H,S., 2011. Chromogenic and fluorogenic sensing of Cu 2+ based on coumarin. Tetrahedron, 67, 2794- 2802. Hirayama, T., Okuda, K.&Nagasawa, H., 2013. A highly selective turn-on fluorescent probe for iron (II) to visualize labile iron in living cells. Chemical Science, 4, 1250-1256.
  8. Hua, J., Wang and Y.G., 2004. A highly selective and sensitive fluorescent chemosensor for Fe 3+ in physiological aqueous solution. Chemistry letters, 34, 98-99.
  9. Ieda, N., Yamada, S., N.&Nakagawa, Kawaguchi, M., H., 2016. Miyata, (7-Diethylaminocoumarin-4-yl) methyl ester of suberoylanilide hydroxamic acid as a caged inhibitor for photocontrol of histone deacetylase activity. Bioorganic & medicinal chemistry, 24, 2789-2793.
  10. Jiang, Z.J., Lv, H.S., Zhu,