Journals / Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi / 2022 / Cilt: 22 - Sayı: 1

A New Perspective towards Diagnosis of Sleep Apnea: Isoprene Detection Using PSSA-g-PANI based SAW Sensor

Uyku Apnesi Teşhisine Yeni Bir Bakış Açısı: PSSA-g-PANI tabanlı SAW Sensörü Kullanarak İzopren Tespiti

Pages
16–22
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Sensor measurements reveal that PSSA-g-PANI based SAW type sensor detected (1-150) ppm isoprene gas with high sensitivity and thus PSSA-g-PANI based SAW type sensor may enable monitor and control of sleep apnea.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Cellular metabolic changes triggered by Obstructive Sleep Apnea Syndrome (OSAS) are detected invasively by detecting isoprene as a biomarker of OSAS in the breath.
📊
Key Findings & Data:When falling asleep, isoprene level begins to increase above 3 ppm.
💡
Conclusion & Impact:Sensor measurements reveal that PSSA-g-PANI based SAW type sensor detected (1-150) ppm isoprene gas with high sensitivity and thus PSSA-g-PANI based SAW type sensor may enable monitor and control of sleep apnea.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Cellular metabolic changes triggered by Obstructive Sleep Apnea Syndrome (OSAS) are detected invasively by detecting isoprene as a biomarker of OSAS in the breath. When falling asleep, isoprene level begins to increase above 3 ppm. Therefore, monitoring isoprene levels in exhaled breath under normal conditions may provide a non-invasive method to detect, monitor, and control sleep disorders such as sleep apnea. In this study, PSSA-g-PANI based SAW gas sensors were prepared and tested against isoprene gas. Sensor measurements reveal that PSSA-g-PANI based SAW type sensor detected (1-150) ppm isoprene gas with high sensitivity and thus PSSA-g-PANI based SAW type sensor may enable monitor and control of sleep apnea.

Özet

Obstrüktif Uyku Apne Sendromu (OSAS) tarafından tetiklenen hücresel metabolik değişiklikler, nefeste OSAS'ın biyobelirteci olarak izopren saptanarak invazif olarak tespit edilir. Uykuya dalındığında izopren seviyesi 3 ppm'nin üzerine çıkmaya başlar. Bu nedenle, normal koşullar altında solunan nefeste izopren seviyelerinin izlenmesi, uyku apnesi gibi uyku bozukluklarını tespit etmek, izlemek ve kontrol etmek için invazif olmayan bir yöntem sağlayabilir. Bu çalışmada, PSSA-g-PANI tabanlı SAW gaz sensörleri hazırlanmış ve izopren gaza karşı test edilmiştir. Sensör ölçümleri, PSSA-g-PANI tabanlı SAW tipi sensörün yüksek hassasiyetle (1-150) ppm izopren gazı algıladığını ve dolayısıyla PSSA-g-PANI tabanlı SAW tipi sensörün uyku apnesinin izlenmesini ve kontrolünü sağlayabileceğini ortaya koymaktadır.

🔖

Cite This Article

TAŞALTIN, C., BAYTEMİR, G., TAŞALTIN, N. (2022). A New Perspective towards Diagnosis of Sleep Apnea: Isoprene Detection Using PSSA-g-PANI based SAW Sensor. Afyon Kocatepe Üniversitesi Fen ve Mühendislik Bilimleri Dergisi, Cilt: 22 - Sayı: 1, 16–22. https://ajindex.com/articles/429595

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Bae, S., Lee, J. U., Park H., Jung E. H., Jung J. W., Jo W. H. 2014. Enhanced performance of polymer solar cells with PSSA-g-PANI/Graphene oxide composite as hole transport layer. Solar Energy Materials and Solar Cells, 130, 599-604.
  2. Ballantine, D. S., Martin, S. J., Ricco, A. J., Frye, G. C., Wohltjen, H., White, R. M., Zellers, E. T. 1997. Acoustic Wave Sensors: Theory, Design, and Physico-Chemical Applications. 1st Edition.
  3. Academic Press,
  4. San Diego, CA, USA. Bikov, A., Hull, J. H., Kunos, L. 2016. Exhaled breath analysis, a simple tool to study the pathophysiology of obstructive sleep apnoea. Sleep Medicine Reviews, 27, 1-8.
  5. Cailleux, A., Allain, P. 1989. Isoprene and Sleep. Life Sciences, 44, 1877-1880.
  6. Carpagnano, G. E. 2011. Exhaled Breath Analysis and Sleep. Journal of Clinical Sleep Medicine, 7(5), S34-S37. Devkota, J., Ohodnicki, P. R., Greve, D. W. 2017. SAW Sensors for Chemical Vapors and Gas. Sensors, 17(4), 801. Finamore, P., Scarlata, S., Cardaci, V., Incalzi, R. A. 2019. Exhaled Breath Analysis in Obstructive Sleep Apnea Syndrome: A Review of the Literature. Medicina, 55(9), 538. Gami, A. S., Olson, E. J., Shen, W. K., Wright, R. S., Ballman, K. V., Hodge, D. O., Herges, R. M., Howard, D. E., Somers, V. K. 2013. Obstructive Sleep Apnea and the Risk of Sudden Cardiac Death: A Longitudinal Study of 10,701 Adults. Journals of American College of Cardiology, 62, 610-616.
  7. Gouma, P. I. 2018. Isoprene sensor/breathalyzer for monitoring sleep disorders. 17th International Meeting on Chemical Sensors – IMCS, Conference Book, 55-56.
  8. Gouma, P., Prasad, A., Stanacevic, S. 2011. A selective Nanosensor Device for Exhaled Breath Analysis. Journal of Breath Research, 5(3), 037110. Göpel, W., Hesse, J., Zemel, J. N. 1991. Chemical and biochemical sensors. Volume 2, VCH Weinheim, 716. Göpel, W., Jones, T. A., Kleitz, M., Lundström, I., Seiyama, T. 2008.
  9. Sensors, Chemical and Biochemical Sensors. Volume 2 Wiley. John Wiley & Sons: Hoboken, NJ, USA. Holty, J.-E. C., Owens, D. K., Dallas, P., Shekelle, P., Qaseem, A., Starkey, M. 2013. Management of Obstructive Sleep Apnea in Adults: A Clinical Practice Guideline from the American College of Physicians. Annals of Internal Medicine, 159(7), 471-483.
  10. Jakubik, W.P. 2011. Surface acoustic wave-based gas sensors. Thin Solid Films, 520, 986-993.
  11. King, J., Kupferthaler, A., Frauscher B., Hackner, H., Unterkofler, K. Teschl, G., Hinterhuber, H., Amann, A., and Högl B. 2012. Measurement of endogenous acetone and isopren