Journals / Laparoscopic Endoscopic Surgical Science / 2021 / Cilt: 28 - Sayı: 1

Comparison of complications associated with the use of three different uterine manipulators (Clermont-Ferrand, VCare, and RUMI II) in total laparoscopic hysterectomy

Pages
18–23
Publication Date
2022-09-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Manipulation of the UM, which is an indispensable instrument of the TLH procedure today, by people with skill and experience and the surgeon’s knowledge on the features and limits of the manipulator used will reduce the risk of UM-related complications.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Introduction: In total laparoscopic hysterectomy (TLH), uterine manipulators (UM) are utilized to facilitate dissection by moving the uterus.
📊
Key Findings & Data:Materials and Methods: In this retrospectively designed study, 103 patients who underwent TLH due to benign indications were included in the study.
💡
Conclusion & Impact:Conclusion: Manipulation of the UM, which is an indispensable instrument of the TLH procedure today, by people with skill and experience and the surgeon’s knowledge on the features and limits of the manipulator used will reduce the risk of UM-related complications.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Introduction: In total laparoscopic hysterectomy (TLH), uterine manipulators (UM) are utilized to facilitate dissection by moving the uterus. However, some complications may occur during the utilization of a manipulator. The aim of this study is to compare the complications that occur during the utilization of three different manipulators. Materials and Methods: In this retrospectively designed study, 103 patients who underwent TLH due to benign indications were included in the study. All patients were operated by the same two surgeons using the same technique. The patients were divided into three groups according to the manipulators utilized. Group 1 (G1) included patients operated with Clermont-Ferrand UM, Group 2 (G2) included patients operated with RUMI II, and Group 3 (G3) included patients operated with VCare. UM-related complications, duration of operation, estimated amount of bleeding, duration of hospital stay, uterine weight, uterine length, number of myomas, and diameter of the largest myoma were recorded. Results: Uterine weight and mean blood loss were higher in G1 than in G3. There was no significant difference between the groups in terms of uterine perforation. Penetration of the manipulator into the mesorectum occurred in one patient in G1 with Douglas perforation. There were two cervical cup melts in G2 and 1 in G3. Cuff dehiscence occurred in one patient each in G2 and G3. Conclusion: Manipulation of the UM, which is an indispensable instrument of the TLH procedure today, by people with skill and experience and the surgeon’s knowledge on the features and limits of the manipulator used will reduce the risk of UM-related complications.

🔖

Cite This Article

Yavuzkır, Ş., Aslan, M. (2022). Comparison of complications associated with the use of three different uterine manipulators (Clermont-Ferrand, VCare, and RUMI II) in total laparoscopic hysterectomy. Laparoscopic Endoscopic Surgical Science, Cilt: 28 - Sayı: 1, 18–23. https://ajindex.com/articles/423540

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Lee PI, Lee YT, Lee SH, Chang YK. Advantages of total laparoscopic hysterectomy. J Am Assoc Gynecol Laparosc 1996
  2. S24–5. [CrossRef] 2. Hasson HM, Rotman C, Rana N, Asakura H. Experience with laparoscopic hysterectomy. J Am Assoc Gynecol Laparosc 1993
  3. 1–1. [CrossRef] 3. Janssen PF, Brölmann HA, Huirne JA. Recommendations to prevent urinary tract injuries during laparoscopic hysterectomy: A systematic Delphi procedure among experts. J Minim Invasive Gynecol 2011
  4. 314–21. [CrossRef] 4. van den Haak L, Alleblas C, Nieboer TE, Rhemrev JP, Jansen FW. Efficacy and safety of uterine manipulators in laparoscopic surgery: A review. Arch Gynecol Obstet 2015
  5. 1003–11. 5. Misirlioglu S, Boza A, Urman B, Taskiran C. Clermont-Ferrand versus vectec uterine manipulator for total laparoscopic hysterectomy. Minim Invasive Ther Allied Technol 2019
  6. 51– 6. [CrossRef] 6. Mettler L, Nikam YA. A comparative survey of various uterine manipulators used in operative laparoscopy. Gynecol Surg 2006
  7. 239–43. [CrossRef] 7. Nassif J, Wattiez A. Clermont Ferrand uterine manipulator. Surg Technol Int 2010
  8. 225–31. 8. Ng CC, Chern BS, Siow AY. Retrospective study of the success rates and complications associated with total laparoscopic hysterectomy. J Obstet Gynaecol Res 2007
  9. 512–8. 9. Macciò A, Chiappe G, Kotsonis P, Nieddu R, Lavra F, Serra M, et al. Surgical outcome and complications of total laparoscopic hysterectomy for very large myomatous uteri in relation to uterine weight: A prospective study in a continuous series of 461 procedures. Arch Gynecol Obstet 2016
  10. 525–31. 10. Wu HH, Yeh GP, Hsieh TC. Iatrogenic uterine rupture caused by overinflation of RUMI manipulator balloon. J Minim Invasive Gynecol 2005
  11. 174–6. [CrossRef] 11. Akdemir A, Cirpan T. Iatrogenic uterine perforation and bowel penetration using a Hohlmanipulator: A case report. Int J Surg Case Rep 2014
  12. 271–3. [CrossRef] 12. Seki T, Hamada Y, Ichikawa T, Onota S, Nakata M, Takakura S. Uterine artery pseudoaneurysm caused by a uterine manipulator. Gynecol Minim Invasive Ther 2017
  13. 25–7. [CrossRef] 13. Abdel Khalek Y, Bitar R, Christoforou C, Garzon S, Tropea A, Biondi A, et al. Uterine manipulator in total laparoscopic hysterectomy: Safety and usefulness. Updates Surg 2020
  14. 1247–54. [CrossRef] 14. Taşkın S, Şükür YE, Turgay B, Altin D, Ortaç F. Vaginal cuff dehiscence following total laparoscopic hysterectomy by monopolar cut vs coagulation mode during colpotomy: A randomized controlled trial.