Journals / Politeknik Dergisi / 2008 / Cilt: 11 Sayı: 4

Comparison of Experimental and Numerical Heat Transfer Results in Concentric Pipe Heat Exchangers

Eşmerkezli Boru Tipli Isı Değiştiricilerinde Deneysel ve Sayısal Isı Transferi Sonuçlarının Karşılaştırılması

Pages
345–352
Publication Date
2008-12-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In addition, temperature distributions, velocity distributions and pressure distributions obtained by FLUENT code program were presented

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, heat transfer from turbulence flowed hot air with different volumetric flow rates to cold water with constant flow rate was investigated numerically and experimentally in concentric pipe heat exchanger under state steady conditions.
📊
Key Findings & Data:The experimental results formed between 2500-19200 Reynolds numbers as heat transfer, Nusselt number, friction factor and pressure drops were compared with the obtained results using three-dimensional FLUENT code program based on finite volume.
💡
Conclusion & Impact:In addition, temperature distributions, velocity distributions and pressure distributions obtained by FLUENT code program were presented
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Eşmerkezli Borulu Isı değiştiricileri · Türbülanslı Akış · Basınç Düşüşü

Abstract

In this study, heat transfer from turbulence flowed hot air with different volumetric flow rates to cold water with constant flow rate was investigated numerically and experimentally in concentric pipe heat exchanger under state steady conditions. The experimental results formed between 2500-19200 Reynolds numbers as heat transfer, Nusselt number, friction factor and pressure drops were compared with the obtained results using three-dimensional FLUENT code program based on finite volume. The experimental and numerical values were seen in a good agreement with each other. In addition, temperature distributions, velocity distributions and pressure distributions obtained by FLUENT code program were presented

Özet

Bu çalışmada, eşmerkezli boru tipi bir ısı değiştiricisinde sürekli rejim şartlarında türbülans akışlı farklı hacimsel debilerindeki sıcak hava ile sabit debili soğuk suyun ısı transferi değerleri deneysel ve sayısal olarak incelenmiştir. Deneysel olarak yapılan çalışmada elde edilen Reynolds (Re) sayısının 2500 – 19200 aralığında oluşan ısı transferi, Nusselt (Nu) sayısı, sürtünme faktörü ve basınç kayıpları, üç boyutlu sonlu hacimler tabanlı FLUENT programında analiz edilerek deneysel ve sayısal sonuçlar karşılaştırılmıştır. Deneysel ve sayısal olarak elde edilen değerlerin birbirleriyle uyum içersinde olduğu görülmüştür. Buna ilaveten sayısal analizle elde edilen sıcaklık dağılımları, hız dağılımları ve basınç dağılımları verilmiştir.

🔖

Cite This Article

Baysal, E. (2008). Comparison of Experimental and Numerical Heat Transfer Results in Concentric Pipe Heat Exchangers. Politeknik Dergisi, Cilt: 11 Sayı: 4, 345–352. https://ajindex.com/articles/422325