Journals / Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi / 2019 / Cilt: 25 - Sayı: 5

Performance analysis of stand-alone hybrid (wind-photovoltaic) energy system

Şebekeden bağımsız hibrit sistemin (rüzgar-fotovoltaik) performans analizi

Pages
571–576
Publication Date
2019-10-21
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The system is modelled depending on the datasheets of the components, and the modelling results are compared with experimental results.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Sizing of PV panel, wind turbine and storage batteries in hybrid energy systems is the most important research topic for a system design.
📊
Key Findings & Data:In this study, experimental and simulation performance differences of the installed hybrid system are presented.
💡
Conclusion & Impact:The system is modelled depending on the datasheets of the components, and the modelling results are compared with experimental results.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Hibrit sistem · Yenilenebilir enerji · Rüzgar enerjisi

Abstract

Sizing of PV panel, wind turbine and storage batteries in hybrid energy systems is the most important research topic for a system design. There are many studies in the literature, using different approaches about sizing of hybrid renewable energy systems. In this study, experimental and simulation performance differences of the installed hybrid system are presented. The system that is installed in Yildiz Technical University, has 600 W wind turbine, 2x320 W photovoltaic (PV) panel group and 4x210 Ah batteries. A maximum power point tracking (MPPT) controller, a hybrid controller and an inverter are utilized to control the panels, wind turbine and power flow. A weather station is used to measure the weather conditions such as wind speed, temperature, radiation, and electrical quantities are recorded by a data logger. The system is modelled depending on the datasheets of the components, and the modelling results are compared with experimental results.

Özet

Hibrit enerji sistem tasarımında fotovoltaik panel, rüzgar türbini ve akülerin boyutlandırılması en önemli araştırma konusudur. Literatürde hybrid yenilenebilir enerji sistemlerinin boyutlandırılmasında farklı yaklaşımlar kullanan çok sayıda çalışma bulunmaktadır. Bu çalışmada, kurulan bir hibrit sistemin deneysel ve simülasyon sonuçları arasındaki farklılıklar ortaya konmuştur Yıldız Teknik Üniversite’sinde kurulan sistem 600 W rüzgar türbini, 2x320 W fotovoltaik panel ve 4x210 Ah akü içermektedir. Maksimum güç noktası takip kontrol cihazı, hibrit kontrolcü ve inverter sırasıyla panel, türbin ve çıkış gücü kontrolü için kullanılmıştır. Hava istasyonu rüzgar hızı, sıcaklık, ışınım gibi hava verilerini kaydetmek için ve veri kaydedici de elektriksel büyüklükleri kayıt altına almak için kullanılmıştır. Sistem kullanılan bileşenlerin katalog bilgilerine göre modellenmiştir ve modelleme sonuçları ile uygulama sonuçları karşılaştırılmıştır.

🔖

Cite This Article

ARIKAN, O., İŞEN, E., KEKEZOĞLU, B. (2019). Performance analysis of stand-alone hybrid (wind-photovoltaic) energy system. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 25 - Sayı: 5, 571–576. https://ajindex.com/articles/42179

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Park H, Kim YJ, Kim H. “PV cell model by single-diode electrical equivalent circuit”. Journal of Electrical Engineering and Technology, 11(5), 1323-1331, 2016.
  2. Global Wind Energy Council. “Global wind statistics 2016”.
  3. Brussels, Belgium, 2017.
  4. International Energy Agency. “Renewable energy outlook-World energy outlook 2013”. 197-232, 2013.
  5. European Photovoltaic Industry. “Global market outlook for photovoltaics”. Brussels, Belgium, 2014.
  6. Fara L, Moraru AG, Sterian P, Bobei P, Diaconu A, Fara S. “Building Integrated Photovoltaic (BIPV) systems in Romania. Monitoring, modelling and experimental validation”. Journal of Optoelectronics and Advanced Materials, 15(1), 125-130, 2013.
  7. Aktas A, Ozdemir E, Karakaya A, Ucar M. “Operation and performance of grid-connected solar photovoltaic power system in Kocaeli University”. Journal of Optoelectronics and Advanced Materials, 15(5), 559-564, 2013.
  8. Ghitas A, Mageed HA, El-Rifate A, Schlosser V, Sabry M. “Validation of a new measuring system for performance evaluation of a large module in a desert area”. Journal of Optoelectronics and Advanced Materials, 15(5), 565-570, 2013.
  9. Cubukcu M, Colak M. “Modeling, comparative simulation and practical performance analysis of a stand-alone PV hybrid power system in Turkey”. Journal of Optoelectronics and Advanced Materials, 15(3), 352-360, 2013.
  10. El Fathi A, Nkhaili L, Bennouna A, Outzourhit A. “Performance parameters of a standalone PV plant”. Energy Conversion and Management, 86, 490-495, 2014.
  11. Semaoui S, Arab AH, Bacha S, Azoui B. “Optimal sizing of a stand-alone photovoltaic system with energy management in isolated areas”. Energy Procedia, 36, 358-368, 2013.
  12. Mezzai N, Rekioua D, Rekioua T, Mohammedi A, Idjdarane K, Bacha S. “Modeling of hybrid photovoltaic/ wind/fuel cells power system”. International Journal of Hydrogen Energy, 39(27), 15158-15168, 2014.
  13. Sukchai S, Sirisamphanwong C. “Optimization of stand-alone PV-FC hybrid system under Thailand climate”. Energy Procedia, 56, 309-317, 2014.
  14. Behzadi MS, Niasati M. “Comparative performance analysis of a hybrid PV/FC/battery stand-alone system using different power management strategies and sizing approaches”. International Journal of Hydrogen Energy, 40(1), 538-548, 2015.
  15. Cano A, Jurado F, Sanchez H, Fernandez LM, Castaneda M. “Optimal sizing of stand-alone hybrid systems based on PV/WT/FC by using several methodologies”. Journal of Energy Institute, 87, 330-340, 2014.
  16. Laurentiu F, Dan C. “Output analysis of stand-alone pv s