Journals / Retina-Vitreus / 2021 / Cilt: 30 - Sayı: 1

Two Complications Following Intravitreal Dexamethasone Implantation: Desegmentation of The Implant and Retinal Injury

Pages
86–89
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The aim of the case presentation is to discuss the causes and management of these complications after intravitreal dexamethasone implantation.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Ozurdex® (Allergan, Inc, Irvine, CA, USA) is an intravitreal sustained-release dexamethasone implant known to be effective in the treatment of macular edema.
📊
Key Findings & Data:Common adverse effects of Ozurdex implantation include increased intraocular pressure and cataract progression; however other ocular complications, such as retinal hemorrhage, extra-macular hole, macular hole, desegmentation of the implant, migration of the implant into the anterior chamber might develop.
💡
Conclusion & Impact:The aim of the case presentation is to discuss the causes and management of these complications after intravitreal dexamethasone implantation.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Ozurdex® (Allergan, Inc, Irvine, CA, USA) is an intravitreal sustained-release dexamethasone implant known to be effective in the treatment of macular edema. Common adverse effects of Ozurdex implantation include increased intraocular pressure and cataract progression; however other ocular complications, such as retinal hemorrhage, extra-macular hole, macular hole, desegmentation of the implant, migration of the implant into the anterior chamber might develop. Retinal injury with desegmantation of the implant has not been reported in the literature yet. A 68-year-old woman presented with complaints of decreased visual acuity in her right eye for approximately 1 month. Her medical history included diabetes mellitus that had been present for 10 years. In ophthalmologic examination, her corrected visual acuity was 1/10 in the right eye and 8/10 in the left eye. The patient was diagnosed with macular edema associated with diabetic retinopathy and intravitreal anti-vascular endothelial growth factor injection was performed in the right eye. In spite of three doses intravitreal anti-vascular endothelial growth factor injection, her best corrected visual acuity and cystoid macular edema did not improve. Therefore, intravitreal dexamethasone implant was injected in the right eye due to persistent macular edema. At one month follow up after injection, fundus examination reveled two pieced and one of the pieces was located on the retina. Laser photocoagulation was performed around the dexamethasone implant location. The aim of the case presentation is to discuss the causes and management of these complications after intravitreal dexamethasone implantation.

🔖

Cite This Article

TUNÇ, U., DEMİR, G. (2021). Two Complications Following Intravitreal Dexamethasone Implantation: Desegmentation of The Implant and Retinal Injury. Retina-Vitreus, Cilt: 30 - Sayı: 1, 86–89. https://ajindex.com/articles/417884

References (11)

  1. Haller JA, Bandello F, Belfort R Jr, et al. OZURDEX GENEVA Study Group. Randomized, sham-controlled trial of dexamethasone intravitreal implant in patients with macular edema due to retinal vein occlusion. Ophthalmology. 2010;117:1134-46
  2. Chiang A, Haller JA The dexamethasone drug delivery system: indications and evidence Adv Ther 2011;28:351-66
  3. Fassbender Adeniran JM, Jusufbegovic D, Schaal S. Common and Rare Ocular Side-effects of the Dexamethasone Implant. Ocul Immunol Infl amm. 2017;25:834-40
  4. Schmitz K, Maier M, Clemens CR, et al. German Retinal Vein Occlusion Group. Reliability and safety of intravitreal Ozurdex injections. The ZERO study Ophthalmologe 2014;111:44-52
  5. Christensen L, Sanders R, Olson J. “Magic Bullet”: Eccentric Macular Hole as a Complication from Dexamethasone Implant Insertion. Case Rep Ophthalmol Med. 2016;2016:1706234
  6. Agrawal R, Fernandez-Sanz G, Bala S, et al. Desegmentation of Ozurdex implant in vitreous cavity: report of two cases. Br J Ophthalmol. 2014;98:961-3
  7. Donmez O, Parlak M, Yaman A, et al. Splitting of a Dexamethasone implant (Ozurdex) following the injection. Case Rep Ophthalmol Med. 2013;2013:247949
  8. Meyer CH, Klein A, Alten F, et al. Release and velocity of micronized dexamethasone implants with an intravitreal drug delivery system: kinematic analysis with a high-speed camera Retina. 2012;32:2133-40
  9. Ernst B.J, Velez-Montoya R, Kujundzic D, et al. “Experimental measure of retinal impact force resulting from intraocular foreign body dropped onto retina through media of differing viscosity,” Clinical & Experimental Ophthalmology, 41;5:471-5, 2013
  10. Christensen L, Sanders R, Olson J. “Magic Bullet”: Eccentric Macular Hole as a Complication from Dexamethasone Implant Insertion. Case Rep Ophthalmol Med. 2016;2016:1706234
  11. Stefano C, Enrico B, Giorgio M. Retinal and vitreous hemorrhage after traumatic impact of dexamethasone implant in a vitrectomized eye. Eur J Ophthalmol 2016; 26: e55-e57