Journals / Türk Biyokimya Dergisi / 2021 / Cilt: 46 - Sayı: 2

Papiller tiroid kanseri hastasında serum tiroglobulin düzeyinin yorumlanmasında gözden kaçan bir durum

An overlooked situation in the interpretation of serum thyroglobulin level in a papillary thyroid cancer patient

Pages
223–226
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Bu olgu sunumu gereksiz klinik müdahalelerin önlenmesinde klinisyen ve laboratuvar arasında erken iletişimin ve yakın iş birliğinin önemini göstermektedir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Papiller tiroid kanseri tanısı almış total tiroidektomi ve radyoaktif iyot ablasyon tedavisi uygulanmış 61 yaşındaki kadın hastada tiroglobulin (TGB) ölçüm interferansı olgu sunu sunmaktayız.
📊
Key Findings & Data:Serum TGB ölçümü Beckman Coulter Unicel DxI 800 cihazı kullanılarak kemilüminesans yön tem ile gerçekleştirildi.
💡
Conclusion & Impact:Bu olgu sunumu gereksiz klinik müdahalelerin önlenmesinde klinisyen ve laboratuvar arasında erken iletişimin ve yakın iş birliğinin önemini göstermektedir.
🔬Design:Lab & Field Experiment
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Papiller tiroid kanseri tanısı almış total tiroidektomi ve radyoaktif iyot ablasyon tedavisi uygulanmış 61 yaşındaki kadın hastada tiroglobulin (TGB) ölçüm interferansı olgu sunu sunmaktayız. Takipte olan hastanın klinik durumu ile uyumsuz serum TGB sonucu nedeniyle olası TGB interfe ransı incelendi. Serum TGB ölçümü Beckman Coulter Unicel DxI 800 cihazı kullanılarak kemilüminesans yön tem ile gerçekleştirildi. İnterferans varlığını araştırmak amacıyla seri dilüsyon, polietilen glikol (PEG) ile çök türme, heterofil antikor bloke eden tüp (HBT) ile muamele yapılarak TGB ölçüldü. Ayrıca romatoid faktör (RF) seviyesi ve alternatif bir yöntemle TGB ölçümü gerçekleştirildi. Seri dilüsyon yapılarak elde edilen değerler doğrusallık göste rirken PEG sonrası ve HBT ile muamele sonrası ölçülen TGB değerlerinde belirgin düşüş gözlendi. Aynı numuneden farklı bir cihazda yapılan TGB ölçümününde de TGB değerinin fonksiyonel duyarlılık seviyesinin altında olması serum örneğinde heterofil antikorlar varlığı kaynaklı TGB interferansı geliştiğini düşündürdü. Klinisyen tarafından hastanın serum TGB ölçümünde analitik interferans varlı ğından şüphelenilmeden önce; hastaya gereksiz pahalı görüntüleme yöntemleri uygulanmış ve ek olarak lenf nodu ince iğne aspirasyon biyopsisi gibi girişimsel işlemler yapılmıştı. Bu olgu sunumu gereksiz klinik müdahalelerin önlenmesinde klinisyen ve laboratuvar arasında erken iletişimin ve yakın iş birliğinin önemini göstermektedir.

Özet

Abstract: In the present study we report a case of thyroglobulin (TGB) measurement interference in a total thyroidectomized and radio-ablated 61-year old woman with papillary thyroid cancer. We investigated possible interference in the measurement of TGB due to discordant TGB in relation to clinical condition during the follow-up period. Serum TGB was measured with the chemilumi nescence method using Beckman Coulter Unicel DxI 800 instrument. To investigate possible interference in TGB measurement serial dilutions, polyethylene glycol preci pitation (PEG), treatment with heterophile blocking tube (HBT), rheumatoid factor level determination and retes ting of TGB with an alternative method were performed. Serial dilutions of the serum sample revealed linearity but a remarkable decrease in TGB in the patient’s serum samples post PEG and post HBT treatments. Also, TGB results under functional sensitivity level obtained with a different method suggested that TGB interference deve loped due to heterophile antibody presence in the serum sample. The patient had unnecessarily undergone expensive imaging techniques, and invasive procedures such as lymph node fine needle aspiration biopsy, before the analytical interference was suspected by the clinician. This report illustrates the importance of early communi cation and close collaboration between clinicians and laboratorians in order to avoid unnecessary clinical intervention.

🔖

Cite This Article

ŞİRİN, F. B., KORKMAZ, H. (2021). Papiller tiroid kanseri hastasında serum tiroglobulin düzeyinin yorumlanmasında gözden kaçan bir durum. Türk Biyokimya Dergisi, Cilt: 46 - Sayı: 2, 223–226. https://ajindex.com/articles/409137

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Guber HA, Farag AF. Evaluation of endocrine function. In: McPherson RA, Pincus MR, editors. Henry’s clinical diagnosis and management by laboratory methods, 23rd ed. St Louis, Missouri: Elsevier; 2017:362–95
  2. Evans C, Tennant S, Perros P. Serum thyroglobulin in the monitoring of differentiated thyroid cancer. Scand J Clin Lab Investig 2016;76:119–23
  3. Haugen BR, Alexander EK, Bible KC, Doherty GM, Mandel SJ, Nikiforov YE, et al. 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American thyroid association guidelines task force on thyroid nodules and differentiated thyroid cancer. Thyroid 2016;26:1–133
  4. Giovanella L, Clark PM, Chiovato L, Duntas L, Elisei R, FeldtRasmussen U, et al. Thyroglobulin measurement using highly sensitive assays in patients with differentiated thyroid cancer: a clinical position paper. Eur J Endocrinol 2014;171: 33–46
  5. Giovanella L, Castellana M, Trimboli P. Unstimulated highsensitive thyroglobulin is a powerful prognostic predictor in patients with thyroid cancer. Clin Chem Lab Med 2019;58:130–7
  6. Sturgeon CM, Viljoen A. Analytical error and interference in immunoassay: minimizing risk. Ann Clin Biochem 2014;48: 418–32
  7. Astarita G, Gutierrez S, Kogovsek N, Mormandi E, Otero P, Calabrese C, et al. False positive in the measurement of thyroglobulin induced by rheumatoid factor. Clin Chim Acta 2015; 447:43–6
  8. Preissner CM, O’Kane DJ, Singh RJ, Morris JC, Grebe SK. Phantoms in the assay tube: heterophile antibody interferences in serum thyroglobulin assays. J Clin Endocrinol Metabol 2003;88: 3069–74
  9. Giovanella L, Keller F, Ceriani L, Tozzoli R. Heterophile antibodies may falsely increase or decrease thyroglobulin measurement in patients with differentiated thyroid carcinoma. Clin Chem Lab Med 2009;47:952–4
  10. Ismail AA. On detecting interference from endogenous antibodies in immunoassays by doubling dilutions test. Clin Chem Lab Med 2007;45:851–4.