Journals / Turkish Neurosurgery / 2019 / Cilt: 29 - Sayı: 3

Identification of Risk Factors for Postoperative Cerebrospinal Fluid Leakage and Comparison of Two Alternative Dural Augmentation Techniques in Posterior Fossa and Spinal Surgeries

Pages
377–385
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Non-tumoral pathologies, previoussurgery, and postoperative hydrocephalus appear to be independent risk factors for postoperative CSF leakage.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:AIM: To investigate comparative efficacy of a novel absorbable adhesive membrane (TissuePatchDuralTM “TPD”) and a fibrin glue(Tisseel “T”) in reducing cerebrospinal fluid (CSF) leaks after posterior fossa and spinal procedures, and also to identify potentialrisk factors for CSF leakage.MATERIAL and METHODS: This is a single-center, retrospective cohort study of 123 consecutive posterior fossa (n=77) and spinal(n=46) surgeries.
📊
Key Findings & Data:Patients were grouped based on dural sealants used 2-group comparison: TPD (n=56) vs. no-TPD (n=67) and3-group comparison: T only (n=43), TPD only (n=32) vs TPD+T (n=35).RESULTS: Mean age was 38.9 ± 22.2 years (62 males, 61 females).
💡
Conclusion & Impact:Non-tumoral pathologies, previoussurgery, and postoperative hydrocephalus appear to be independent risk factors for postoperative CSF leakage.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

AIM: To investigate comparative efficacy of a novel absorbable adhesive membrane (TissuePatchDuralTM “TPD”) and a fibrin glue(Tisseel “T”) in reducing cerebrospinal fluid (CSF) leaks after posterior fossa and spinal procedures, and also to identify potentialrisk factors for CSF leakage.MATERIAL and METHODS: This is a single-center, retrospective cohort study of 123 consecutive posterior fossa (n=77) and spinal(n=46) surgeries. Patients were grouped based on dural sealants used 2-group comparison: TPD (n=56) vs. no-TPD (n=67) and3-group comparison: T only (n=43), TPD only (n=32) vs TPD+T (n=35).RESULTS: Mean age was 38.9 ± 22.2 years (62 males, 61 females). Baseline characteristics were similar between groups. Neither2-group (TPD: 10.4% vs no-TPD: 8.9%; p=0.778) nor 3-group (T: 9.3% vs TPD: 6.3% vs TPD+T: 14.3%; p=0.539) comparisonsrevealed a significant difference in postoperative CSF leakage rates. Multivariate analysis showed that diagnosis (non-tumoral vs.tumor) (OR: 5.487; 95% CI: 1.118-26.937; p=0.036); previous surgery (OR: 9.268; 95% CI: 1.911-44.958; p=0.006), postoperativehydrocephalus (OR: 5.456; 95% CI: 1.250-23.821; p=0.024) were independent predictors of postoperative CSF leakage.CONCLUSION: TissuePatchDuralTM is a novel dural sealant patch which can be safely used to reinforce dural closure in posteriorfossa and spinal surgeries, and its efficacy is comparable to widely used fibrin glue (Tisseel). Non-tumoral pathologies, previoussurgery, and postoperative hydrocephalus appear to be independent risk factors for postoperative CSF leakage.

🔖

Cite This Article

ESER, M. T., HANALIOGLU, S., CETINER, M. Z., DINC, S., PEKER, H. O., SORAR, M., DOLGUN, H., TÜRKOĞLU, E. (2019). Identification of Risk Factors for Postoperative Cerebrospinal Fluid Leakage and Comparison of Two Alternative Dural Augmentation Techniques in Posterior Fossa and Spinal Surgeries. Turkish Neurosurgery, Cilt: 29 - Sayı: 3, 377–385. https://ajindex.com/articles/404387

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Arlt F, Trantakis C, Krupp W, Renner C, Winkler D, Strauss G, et al: Cerebro spinal fluid leak after microsurgical surgery in vestibular schwannomas viaretrosigmoidal craniotomy. Neurol Res 33:947–952, 2011 2. Bakar B, Kose EA, Balcı M, Atasoy P, Sarkaratı B, Alhan A, Kılınc K, Keskil IS: Evaluation of the neurotoxicity of the polyethylene glycol hydrogel dural sealant. Turk Neurosurg 23:16-24,2013 3. Bryce GE, Nedzelski JM, Rowed DW, Rappaport JM: Cerebrospinal fluid leaks and meningitis in acoustic neuroma surgery. Otolaryngol Head Neck Surg 104:81–87,1991 4. Cappabianca P, Cavallo LM, Valente V, Romano I, D’Enza AI, Esposito F, et al: Sellarrepairwith fibrin sealant and collagen fleece after endoscopic endonasal transsphenoidal surgery. Surg Neurol 62:227–233, 2004 5. Cosgrove D: A complex, tissue-specific role for plasmin and its regulators in modulating fibrogenic activity. Am J Physiol Renal Physiol 293:10-11,2007 6. Della Puppa A, Rossetto M, Scienza R: Use of a new absorbable sealing film for preventing postoperative cerebrospinal fluid leaks: Remarks on a new approach. Br J Neurosurg 24:609– 611,2010 7. Dusick JR, Mattozo CA, Esposito F, Kelly DF: Bio Glue for prevention of postoperative cerebro spinal fluid leaks in transsphenoidal surgery: A caseseries. Surg Neurol 66:371– 376, 2006 8. Ferroli P, Acerbi F, Broggi M, Schiariti M, Albanese E, Tringali G: A novel impermeable adhesive membrane to reinforce dural closure: A preliminary retrospective study on 119 consecutive high-risk patients. World Neurosurg 79: 551–557,2013 9. Grotenhuis JA: Costs of postoperative cerebrospinal fluid leakage: 1-year, retrospective analysis of 412 consecutive nontraumacases. Surg Neurol 64:490-494,2005 10. Hutter G, von Felten S, Sailer MH, Schulz M, Mariani L: Risk factors for postoperative CSF leakage after elective craniotomy and the efficacy of fleece-bound tissue sealing against dural suturing alone: A randomized controlled trial: J Neurosurg 127:735-744,2014 11. Jankowitz BT, Atteberry DS, Gerszten PC, Karausky P, Cheng BC, Faugh R: Effect of fibrin glue on the prevention of persistent cerebral spinal fluid leakage after incidental durotomy during lumbar spinal surgery. Eur Spine J 18:1169–1174,2009 12. Kim KD, Wright NM: Polyethylenegly colhydrogel spinal sealant (Dura Seal Spinal Sealant) as an adjunct to sutured dural repair in the spine: Results of a prospective, multicenter, randomized controlled study. Spine (PhilaPa 1976) 36:1906– 1912,2011 13. Kinac