It was found to be 0.70 for RSD % and 0.3 for ±CL (p=0.05).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this article the potentiometric determination of naproxen sodium is described.
📊
Key Findings & Data:A solvent system consisting of aqueous solution of 20% ethanol (v/v) at an ionic strength of 0.1 adding sodium chloride was found to be suitable for the determination of naproxen.
💡
Conclusion & Impact:It was found to be 0.70 for RSD % and 0.3 for ±CL (p=0.05).
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Potensiyometri · Tabletler · Naproksen

Abstract

In this article the potentiometric determination of naproxen sodium is described. A solvent system consisting of aqueous solution of 20% ethanol (v/v) at an ionic strength of 0.1 adding sodium chloride was found to be suitable for the determination of naproxen. Same solvent system was employed for titrant of 0.1 N HCl and to titrate the active material. Validation processes as repeatability (precision) (n=6) were computed. It was found to be 0.70 for RSD % and 0.3 for ±CL (p=0.05). The analysis of 275 and 550 mg naproxen sodium tablets were carried out in the filtered and unfiltered tablet solutions for three consecutive days considering intra and inter-days. Precision values were in the range of 0.16-0.33 for unfiltered and 0.10-0.29 for filtered solutions and the amount of the tablets was found to be in the range of (103.0-108.7%) for unfiltered and (102.9-107.7%) for filtered solutions. The method proposed here is precise simple and rather cheap. Therefore, it is suggested for the routine analysis of naproxen sodium tablets.

Özet

Bu çalışmada, naproksen sodyumun potansiyometrik tayini tanıtılmaktadır. Naproksenin tayini için en iyi çözücü sistemi, sodyum klorür ilavesiyle 0,1 iyonik şiddete ayarlı % 20 etanol (h/h) olarak bulundu. Aktif maddenin titrasyonunda ve 0,1 N HCl için de benzer çözücü sistemi kullanıldı. Validasyon işlemleri tekrarlanabilirlik (kesinlik) (n-6) olarak hesaplandı. % RSD için 0,70 ve CL (p=0,05) için 0,3 olarak hesaplandı. Naproksen sodyumun 275 ve 550 mg'lık tabletlerinin analizi, tablet çözeltilerinin süzülerek ve süzülmeden ardışık üç gün, güniçi ve günlerarası bakımından yapıldı. Kesinlik değerleri, süzülmemiş tablet çözeltileri için 0,16-0,33, süzülmüş tablet çözeltileri için 0,10-0,29 ve tabletlerin miktarı süzülmemişler için (%103,0-108,7), süzülmüşler için (%102,9-107,7) olarak bulundu. Önerilen bu metot tekrarlanabilir, basit ve oldukça ucuzdur. Bu nedenlerle, bu yöntem naproksen sodyum tabletlerinin rutin analizleri için önerilmektedir.

🔖

Cite This Article

UYSAL, Ü. D., TUNÇEL, M. (2004). Naproksen'in tabletlerde birinci türev potansiyometri ile miktar tayini. Turkish Journal of Pharmaceutical Sciences, Cilt: 1 - Sayı: 3, 217–223. https://ajindex.com/articles/403899

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Todd, P., Clissold, A. S. P., "A reappraisal of its pharmacology, and therapeutic use in rheumatic diseases and pain states" Drugs, 40, 91-137,1990
  2. Boynton, C.S., Dick, C.F., Mayor, G.H., "NSAID: An overview" J. Clint. Pharmacology,28,512-517,1988
  3. Murillo Pilgrim, A., Garcia Borneo, L.F.G., "First derivative non near variable-angle synchronous fluorescence spectroscopy for the simultaneous determination of salicylamide,salisilate and naproxen in serum and urine" Anal. Chim. Acta, 373, lly-129,1998
  4. Ahrer, W., Scherwenk, E., Buchberger, W., "Determination of drug residues in water by the combination of liquid chromatography or capillary electrophoresis with electrospray mass spectrometry" J. Chromatogr. A, 910, 69-78, 2000
  5. Mikami, E.T., Goto, Ohno, T., Matsumoto, M., Nishida,M., "Simultaneous analysis of naproxen, nabumetone and its major metabolite 6-methoxy-2-naphtylacetic acid in pharma-ceuticals and human urine by high-performance liquid chromatography" J. Pharm. Biomed.Anal., 23, 917-525, 2000
  6. Martin, MJ., Pablos, F., Gonzaies, A.G., "Simultaneous determination of caffeine and non-steroidal anti-inflammatory drugs in pharmaceutical formulations and blood plasma by reversed-phase HPLC from lineargradient elution" Talanta, 49, 453-459,1999
  7. Cakrt, M., Hercegova, A., Losko Polonsky, J., Sadecka, J., Skacani, I., "Isotachophoretic determination of naproxen in the presence of its metabolite in human serum" J. Chromatogr.A, 916,207-214,2007
  8. Sadecka, J., Cakrt, M., Hercegova, A., Losko Polonsky, J., Skacani, I., "Determination of ibuprofen and naproxen in tablets" J. Pharm. Biomedical Anal., 25, 881-891, 2001 9. Şener, E., Tuncel, M., Aboul-Enein, H.Y., "Rapid determination of naproxen sodium in pharmaceutical formulations by flow injection analysis (FIA) using UV-detection" J. Liq.Chromatogr.& Rel. Technol., 26 (3), 401-408, 2003
  9. Georgiou, M.E., Georgiou, C.A., Koupparis, M.A., "Rapid automated spectrophotometric competitive complexation studies of drugs with cyclodextrins using the flow-injection gradient technique: tricyclic anti-depressant drugs with alpha-cyclodaextrin" Anal. Chem., 67 (1), 114-123,1995
  10. Georgiou, M.E., Georgiou, C.A., Koupparis, M.A., "Flow-injection gradient technique in spectrophotometric determination of formation constants of micromolecule-cyclodextrin complexes" Analyst, 124 (3), 391-396,1991
  11. The United States Pharmacopoeia XXIV, Marck Printing, Co., Easton, Philadelphia, USA, MD 1149,2000