Journals / Turkish Journal of Pharmaceutical Sciences / 2021 / Cilt: 18 - Sayı: 3

Amlodipin Besilat ve Enalapril Maleatın Sabit Dozlu Kombinasyondan Analizi için Deney Tasarımı Yoluyla Bir YBSK Yöntemi Geliştirilmesi ve Validasyonu

Development and Validation of an HPLC Method Using an Experimental Design for Analysis of Amlodipine Besylate and Enalapril Maleate in a Fixed-dose Combination

Pages
66–75
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Optimize edilen yöntemin enalapril ve amlodipin içeren bir sabit dozlu kombinasyonun in vitro performansı ve kalite kontrol testlerinde kullanılabileceği gösterilmiştir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Bu çalışmanın amacı, amlodipin besilat ve enalapril maleat içeren sabit dozlu kombinasyon tabletinden disolüsyon ve miktar tayini analizi için deney tasarımı yaklaşımı ile basit, ekonomik ve sağlam bir yüksek basınçlı sıvı kromatografisi (YBSK) yönteminin geliştirilmesi ve optimizasyonudur.
📊
Key Findings & Data:Gereç ve Yöntemler: Kromatografik analiz C18 kolonda (4,6x250 mm id., 5 μm partikül çapı) gerçekleştirilmiştir.
💡
Conclusion & Impact:Optimize edilen yöntemin enalapril ve amlodipin içeren bir sabit dozlu kombinasyonun in vitro performansı ve kalite kontrol testlerinde kullanılabileceği gösterilmiştir.
🔬Design:Experimental Field Trial
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Amaç: Bu çalışmanın amacı, amlodipin besilat ve enalapril maleat içeren sabit dozlu kombinasyon tabletinden disolüsyon ve miktar tayini analizi için deney tasarımı yaklaşımı ile basit, ekonomik ve sağlam bir yüksek basınçlı sıvı kromatografisi (YBSK) yönteminin geliştirilmesi ve optimizasyonudur. Gereç ve Yöntemler: Kromatografik analiz C18 kolonda (4,6x250 mm id., 5 μm partikül çapı) gerçekleştirilmiştir. Enjeksiyon hacmi 5 μL ve dalga boyu 215 nm’dir. Yöntemin sağlamlığının test edilmesinde Box-Behnken tasarımı kullanılmıştır. Akış hızı (1, 1,2, ve 1,4 mL/dk), kolon sıcaklığı (25°C, 30°C ve 35°C), hareketli fazdaki metanol oranı (%5, %10 ve %15) ve hareketli fazın pH’sı (2,8, 3 ve 3,2) bağımsız değişkenler olarak seçilmiştir. Yöntemin validasyonu ICH kılavuzlarına göre gerçekleştirilmiştir. Tabletlerin çözünme hızı deneyleri USP cihaz 2 kullanılarak 75 devir/dk hızda gerçekleştirilmiştir. Çözünme hızı çalışması 0,1 N HCl’da 37±0,5°C’de yapılmış ve optimize edilen YBSK yöntemi ile analiz edilmiştir. İstatistiksel değerlendirmede çok değişkenli doğrusal regresyon analizi ve ANOVA testi kullanılmıştır. Bulgular: Tüm değişkenler için doğrusal modeller kullanılmıştır. Etkin madde konsantrasyonlarını etkileyen en anlamlı faktör akış hızıdır. Optimize edilen yöntem şu parametreleri içermektedir: 25°C kolon sıcaklığı, hareketli fazda %10 metanol oranı, 2,95 hareketli faz pH’sı ve 1,205 mL/dk akış hızı. Alıkonma zamanları enalapril ve amlodipine için sırasıyla 3,8 dk ve 7,9 dk olarak bulunmuştur. Yöntem amlodipin ve enalapril için sırasıyla 0,8-24 μg/mL (R2 >0,999) ve 1,6-48 (R2 >0,999) μg/mL aralıkta doğrusal bulunmuştur. Her iki etkin madde de 10 dakika içinde %85’ten fazla çözünmüştür. Sonuç: Enalapril maleat ve amlodipin besilatın dozaj formlarından analizinde deney tasarımı faydalı bir yaklaşım olarak görülmüştür. Optimize edilen yöntemin enalapril ve amlodipin içeren bir sabit dozlu kombinasyonun in vitro performansı ve kalite kontrol testlerinde kullanılabileceği gösterilmiştir.

Özet

Objectives: The aim of this study was to develop and optimize a simple, cost-effective, and robust high-performance liquid chromatography (HPLC) method by taking an experimental design approach to the assay and dissolution analysis of amlodipine besylate and enalapril maleate from a fixeddose combination tablet. Materials and Methods: The chromatographic analysis was performed on a C18 column (4.6x250 mm id., particle size of 5 μm). The injection volume was 5 μL, and the detection wavelength was 215 nm. A Box-Behnken design was used to test the robustness of the method. The flow rate (1, 1.2, and 1.4 mL/min), column temperature (25°C, 30°C, and 35°C), methanol ratio of the mobile phase (5, 10, and 15%), and pH of the mobile phase (2.8, 3, and 3.2) were selected as independent variables. The method was validated according to International Conference on Harmonization guidelines. Dissolution of the tablets was performed by using USP apparatus 2 and analyzed using the optimized HPLC method. Multivariate linear regression analysis and ANOVA were used in the statistical evaluation. Results: Linear models were fitted for all variables. The flow rate was the most significant factor affecting the APIs’ concentrations. The optimized method included the following parameters: Column temperature of 25°C, 10% methanol as the mobile phase, pH of 2.95, and flow rate of 1.205 mL/ min. Retention times were 3.8 min and 7.9 min for enalapril and amlodipine, respectively. The method was found to be linear in the range of 0.8-24 μg/mL (R2 >0.999) and 1.6-48 μg/mL (R2 >0.999) for amlodipine and enalapril, respectively. Both APIs were dissolved more than 85% within 10 min. Conclusion: The experimental design was proved as a useful tool for the determination and separation of enalapril maleate and amlodipine besylate in dosage forms. The optimized method can be used for in vitro performance and quality control tests of fixed-dose tablet combinations containing enalapril maleate and amlodipine besylate.

🔖

Cite This Article

YAŞIN, D. S., BİNGÜL, A. A., KARAKÜÇÜK, A., TEKSİN, Z. (2021). Amlodipin Besilat ve Enalapril Maleatın Sabit Dozlu Kombinasyondan Analizi için Deney Tasarımı Yoluyla Bir YBSK Yöntemi Geliştirilmesi ve Validasyonu. Turkish Journal of Pharmaceutical Sciences, Cilt: 18 - Sayı: 3, 66–75. https://ajindex.com/articles/403544

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Schellack N, Malan L. An overview of fixed-dose combinations of antihypertensive drugs in South Africa. S Afr Fam Prac. 2014;56:206- 211. Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, Grassi G, Heagerty AM, Kjeldsen SE, Laurent S, Narkiewicz K, Ruilope L, Rynkiewicz A, Schmieder RE, Struijker Boudier HAJ, Zanchetti A, Vahanian A, Camm J, Caterina R, Dean V, Dickstein K, Filippatos G, FunckBrentano C, Hellemans I, Kristensen SD, McGregor K,Sechtem U, Silber S, Tendera M, Widimsky P, Zamorano JL, Kiowski W, Agabiti-Rosei E, Ambrosioni E, Lindholm LH, Viigimaa M, Adamopoulos S, Agabiti-Rosei E, Ambrosioni E, Bertomeu V, Clement D, Erdine S, Farsang C, Gaita D, Lip G, Mallion J-M, Manolis AJ, Nilsson PM, O’Brien E, Ponikowski P, Redon J, Ruschitzka F, Tamargo J, Zwieten P, Waeber B, Williams B, Management of Arterial Hypertension of the European Society of Hypertension, European Society of Cardiology. Guidelines for the management of arterial hypertension: the task force for the management of arterial hypertension of the European society of hypertension (ESH) and of the European Society of Cardiology (ESC). Eur Heart J. 2007;34:2159-2219.
  2. Mancia G, Fagard R, Narkiewicz K, Redon J, Zanchetti A, Böhm M, Christiaens T, Cifkova R, De Backer G, Dominiczak A, Galderisi M, Grobbee DE, Jaarsma T, Kirchhof P, Kjeldsen SE, Laurent S, Manolis AJ, Nilsson PM, Ruilope LM, Schmieder RE, Sirnes PA, Sleight P, Viigimaa M, Waeber B, Zannad F, Task Force Members. Guidelines for the management of arterial hypertension: the task force for the management of arterial hypertension of the European society of hypertension (ESH) and of the European Society of Cardiology (ESC). J Hypertens. 2013;25:1105-1187. Weir MR. Effect of renin angiotensin system inhibition on end organ protection: can we do better? Clin Ther. 2007;29:1803-1824.
  3. European Medicines Agency, Committee for medicinal products for human use. Guideline on clinical development of fixed dose combination medicinal products; 2017. Available from: https://www.ema.europa.eu/ en/documents/scientific-guideline/guideline-clinical-developmentfixed-combination-medicinal-products-revision-2_en.pdf Patel P, Ordunez P, DiPette D, Escobar MC, Hassel T, Wyss F, Hennis A, Asma S, Angell S, Standardized Hypertension Treatment and Prevention Network. Improved blood pressure control to reduce cardiovascular disease morbidity and mortality: the Standardized Hypertension Treatment and Prevention Project. J Clin Hyperten