Journals / Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2021 / Cilt: 25 - Sayı: 3

Investigation of Electrohemical Behaviors of Some Tetracyclines Using Modified Graphite Electrodes

Modifiye Grafit Elektrotlar Kullanılarak Bazı Tetrasiklinlerin Elektrokimyasal Davranışlarının İncelenmesi

Pages
513–518
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The highest anodic signals of TC, CTC and OTC with modified graphite electrode were obtained in BR buffer solution were prepared in 20% asetonitrile-water at pH 2.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, electrochemical behavior of tetracycline (TC), chlortetracycline (CTC) and oxytetracycline (OTC) were investigated in 20; 30 and 40% acetonitrile-water mixture at the pH of 1.5; 2; 2.5; 3; 4 prepared Britton-Robinson (BR) buffers, by the differential pulse voltammetric method.
📊
Key Findings & Data:The effect of the asetonitrile–water ratio and pH, on the performance of the modified graphite electrode (MIP) was investigated and optimized.
💡
Conclusion & Impact:The highest anodic signals of TC, CTC and OTC with modified graphite electrode were obtained in BR buffer solution were prepared in 20% asetonitrile-water at pH 2.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Polipirol · Tetrasiklin · Klortetrasiklin

Abstract

In this study, electrochemical behavior of tetracycline (TC), chlortetracycline (CTC) and oxytetracycline (OTC) were investigated in 20; 30 and 40% acetonitrile-water mixture at the pH of 1.5; 2; 2.5; 3; 4 prepared Britton-Robinson (BR) buffers, by the differential pulse voltammetric method. Voltammetric determinations of TC, CTC and OTC were carried out using molecularly imprinted (MIP) and non-imprinted polypyrrole (NIP) modified graphite electrodes. Both types of electrode were prepared by the cyclic voltammetric method. The effect of the asetonitrile–water ratio and pH, on the performance of the modified graphite electrode (MIP) was investigated and optimized. The highest anodic signals of TC, CTC and OTC with modified graphite electrode were obtained in BR buffer solution were prepared in 20% asetonitrile-water at pH 2.

Özet

Bu çalışmada, Tetrasiklin (TC), Klortetrasiklin (CTC) ve Oksitetrasiklin’in (OTC) elektrokimyasal davranışları % 20; 30 ve 40 asetonitril-su karışımlarında hazırlanan Britton-Robinson (BR) tamponlarında pH 1,5; 2; 2,5; 3 ve 4’ te diferansiyel puls voltametri yöntemiyle incelenmiştir. TC, CTC ve OTC’nin voltametrik çalışmaları moleküler baskılı (MIP) ve baskısız (NIP) polimer modifiye grafit elektrotlar kullanılarak gerçekleştirilmiştir. Her iki tür elektrot da dönüşümlü voltametri yöntemiyle hazırlanmıştır. Asetonitril-su oranı ve pH’nın modifiye grafit elektrodun performansı üzerine olan etkisi incelenmiş ve optimize edilmiştir. TC, CTC ve OTC için modifiye grafit elektrot ile en yüksek anodik sinyaller %20 asetonitril-su karışımında hazırlanan BR tamponu ile pH 2’de elde edilmiştir.

🔖

Cite This Article

AKYÜZ, B. G., ÖZKORUCUKLU, S. P., KIR, E. (2021). Investigation of Electrohemical Behaviors of Some Tetracyclines Using Modified Graphite Electrodes. Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 25 - Sayı: 3, 513–518. https://ajindex.com/articles/397398

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Dökmeci, İ. 2007. Sağlık Yüksek Okulları için Farmakoloji. Medikal Yayıncılık, 9573, İstanbul, 301s
  2. Sapadin, A. N., Fleischmajer, R. 2006. Tetracyclines: Nonantibiotic properties and their clinical implications. Journal of the American Academy of Dermatology, 54(2), 258-265
  3. Özalp Dural, E. A. 2002. Farmakoloji. Genişletilmiş 3. baskı. Nobel Tıp Kitabevleri. Nobel Matbaacılık, 603, İstanbul, 798s
  4. Şenyuva, H., Gilbert, J. 2010. Hayvansal gıda maddelerinde veteriner ilaç kalıntılarının taranması. Food Life International Ltd., Edip Sincer, Sincer Dış Ticaret. https://docplayer.biz.tr/3173220-Hayvansal-gida-maddelerinde-veteriner-ilac kalintilarinin-taranmasi.html (Erişim tarihi: 25.12.2020
  5. Perçin Özkorucuklu, S., Şahin, Y., Alsancak, G. 2008. Voltammetric behavior of sulfamethoxazole on eşectropolymerized-molecularly imprinted overoxidized polypyrrole. Sensors, 8, 8463-8478
  6. Gürler, B., Perçin Özkorucuklu, S., Kır, E. 2013. Voltammetric behavior and determination of doxycycline in pharmaceuticals at molecularly imprinted and non-imprinted overoxidized polypyrrole electrodes. Journal of Pharmaceutical and Biomedical Analysis, 84, 263-268
  7. Perçin Özkorucuklu, S., Özcan, L., Şahin, Y., Alsancak, G. 2011. Electroanalytical determination of some sulfonamides on overoxidized polypyrrole electrodes. Australian Journal of Chemistry, 64, 965-972
  8. Özcan, L., Şahin, Y. 2007. Determination of paracetamol based on electropolymerized-molecularly imprinted polypyrrole modified pencil graphite electrode. Sensors and Actuators B, 127, 362-369
  9. Özcan, L., Şahin, M., Şahin, Y. 2008. Electrochemical preparation of a molecularly imprinted polypyrrole-modified pencil graphite electrode for determination of askorbic acid. Sensors, 8, 5792-5805
  10. Gürler, B. 2011. Bazı tetrasiklinlerin elektrokimyasal davranışlarının belirlenmesi ve voltametrik tayinleri için moleküler baskılanmış polimer modifiye elektrotların hazırlanması. Süleyman Demirel Üniversitesi, Fen Bilimleri Enstitüsü, Doktora Tezi, 116s, Isparta
  11. Cai, W., Gupta, R. B. 2004. Molecularly-imprinted polymers selective for tetracycline binding. Seperation and Purification Technology, 35, 215-221
  12. Kayaalp, S. O. 2005. Tıbbi Farmakoloji. Hacettepe-Taş Yayını, Feryal Matbaacılık, 27, Ankara, 704s
  13. Perçin, S. 2008. Bazı sülfonamitlerin elektrokimyasal ve kromatografik davranışlarının incelenmesi. Süleyman Demirel Üniversitesi, Fen Bilimleri Enstitüsü, Doktora Tezi, 170s, Is