Journals / Tekstil ve Mühendis / 2006 / Cilt: 13 - Sayı: 64

Design of a cooling garment and development of the test method

Soğutucu bir giysi sistemi tasarımı ve test yöntemi geliştirilmesi

Pages
18–32
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The effects of water inlet temperature and flow rate on cooling effect and the differences of manikin temperature are investigated.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The core temperatures of individuals increase when they are working in hot conditions, when they have special illness etc.
📊
Key Findings & Data:In order to decrease these temperatures special garments are needed.
💡
Conclusion & Impact:The effects of water inlet temperature and flow rate on cooling effect and the differences of manikin temperature are investigated.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

The core temperatures of individuals increase when they are working in hot conditions, when they have special illness etc. In order to decrease these temperatures special garments are needed. These garments are called microclimate cooling garments and can be classified as water cooling, air cooling and phase changing material cooling systems. They are used in military clothes, space suits, protective clothes, in surgical clothes and in medical field to relieve the symptoms of special diseases. Liquid cooling garments are one of the most popular topics for investigation as cooling systems abroad. But there is no research about these systems in our country. In this work, a cooling garment, which is different from the other researches, is designed. In order to investigate the cooling effects of this garment, a test method is developed. The effects of water inlet temperature and flow rate on cooling effect and the differences of manikin temperature are investigated.

Özet

Çok sıcak ortamlarda bulunma-çalışma, çeşitli biyolojik rahatsızlıklar gibi durumlar sonucunda insan vücudunun sıcaklığı yükselmektedir. Bu sıcaklığı düşürmek amacıyla özel giysiler kullanılmaktadır. Bu giysilere mikroiklim soğutmalı giysiler adı verilmektedir. Su, hava ve faz değiştiren materyaller kullanarak soğutma yapan sistemler mevcuttur. Askeri alanlarda, uzay giysilerinde ve endüstriyel alanda kullanılan koruyucu giysilerin içinde, tıp alanında çeşitli hastalıkların semptomlarının hafifletilmesinde ve doktorların cerrahi giysilerinin içinde bu sistemler kullanılmaktadır. Mikroiklim soğutmalı giysi çeşitlerinden biri olan su soğutmalı sistemler yurt dışında yaygın olarak araştırılmaktadır. Ancak ülkemizde bu sistemlerle ilgili herhangi bir çalışmaya rastlanmamıştır. Bu çalışmada da yurt dışında oluşturulan diğer soğutucu giysilerden farklı yapıda tıbbi amaçlı su soğutmalı bir giysi tasarlanmış ve bu giysinin soğutma etkisini test etmek için bir test yöntemi geliştirilmiştir. Yapılan deneylerde su giriş sıcaklığının ve suyun debisinin değişimlerinin soğutmaya etkisi ve mankenin vücut sıcaklığı değişimleri incelenmiştir.

🔖

Cite This Article

KAYACAN, Ö., KURBAK, A. (2006). Design of a cooling garment and development of the test method. Tekstil ve Mühendis, Cilt: 13 - Sayı: 64, 18–32. https://ajindex.com/articles/366138

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. Adıgüzel, Ö., 2007, Ektodermal Displazi, www.ektodermaldisplazi.com Ames Research Center, 1993.
  2. New Help For Ms Patients, Spinoff93,52-55, www.sti.nasa.gov Burton, D.R., Collier, L., 1964. The Development of Water Conditioned Suits. Tech. Note ME-400, Royal Craft Establishment, Farnborough Cao H., Branson, D.H., Peksöz, S., Nam, J., Farr, C.A., 2006, Fabric Selection for A liquid Cooling Garment, Textile Research Journal, Cilt: 76, Sayı 7,586-595
  3. Chambers, A.B., 1970. Controlling thermal comfort in the EVASpace Suit, ASHRAE J., Mart, 33-38.
  4. Dionne J.-P., Semeniuk,K.,Makris,A.,Teal,W.,Laprice, B., Thermal Manikin Evaluation of Liquid Cooling Garments intended for use in Hazardous Waste Management, WM'03 Conference, 2003,
  5. Tucson, ABD Hexamer, M., Werner, J., 1994. Strategies for Automatic Control Of Cooling Garments. 6. International Congress of Environmental Ergonomics, Montebello, Kanada Space Life Sciences, Cilt:2, Sayi:3,335-360.
  6. Hexamer, M., Xu, X., Werner, J., 1996. Automatic Multı- loop Control of Cooling Garments, 7. International Congress on Environmental Ergonomics, Kudüs, İsrail Hexamer, M., Werner, J., 1998. Automatic control of iquid cooling garments: What is the ideal control mode?, 8.International Congress on Environmental Ergonomics, San Diego ABD Jette, F.X., Dionne, J.-R, Rose J., Makris, A., 2004. Effect of thermal Manikin Surface Temperature on the Perrormance ot Personel Cooling Systems, European Journal of Applied Physiology. Katsuura, T., Hiroshi, O., Yasuyuki, K., 1990. Effects of Head Cooling on Man During Light Exercise in A Hot Environment, International Congress on Environmental Ergonomics, Austin, ABD. Kayacan, Ö., Doktora Tezi, DEÜ. Fen Bilimleri Enst,2007
  7. Kinnman, J., Andersson, U., Wetterquist, L., Kinnman, Y., Andersson, U., 2000. Cooling Suit for Multiple Sclerosis:Functional improvement in Daily Living?, Scand J Rehab Med, 32,20-24
  8. Kraft H.G.H., Alquist A.D., 1996. Effect of Microclimate Cooling on Physical Function in MS, Rehabilitation R&D Progress Reports Ku, Y.-T, Montgomery, L.D., Wenzel, K., Webbon, B., Burks, J. S., 1999. Physiologic and Thermal Responses of Male and Female Patients with Multiple Sclerosis to Head and Neck Cooling, Physical Medicine & Rehabilitation, Cilt:78(5), 447-456.
  9. NASA explores, September 26, 2002, www.nasaexplores.com NASA/MS çalışma grubu tarafından, 2003. A Randomized Controlled Study of the Acute and Chronic Effects of Cooling Therapy for MS, Neurology, Haziran,1955-1960 NFED (Ulusal Ekto