Journals / The Anatolian Journal of Cardiology / 2016 / Cilt: 16 - Sayı: 7

Prediction of recurrence after cryoballoon ablation therapy in patients with paroxysmal atrial fibrillation

Pages
482–488
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the receiver operating characteristic analysis, LAAV of >30 cm/s had a sensitivity of 85% and a specificity of 95% for predicting success after ablation (AUC=0.813; 95% CI: 0.76-0.92; p<0.0001).Conclusion: The presence of MAC, increased LA diameter, the existence of LASEC, low LAAV, and low peak PV systolic wave velocity are parameters that can predict the recurrence of AF after cryoablation.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The purpose of this study was to investigate the factors predicting the maintenance of sinus rhythm in patients with paroxysmal atrial fibrillation (PAF) who underwent cryoablation of the pulmonary veins (PVs).
📊
Key Findings & Data:Methods: Fifty-one patients (54.6±10.4 years) with paroxysmal AF who underwent the cryoablation of the PVs were to the prospective trial.
💡
Conclusion & Impact:In the receiver operating characteristic analysis, LAAV of >30 cm/s had a sensitivity of 85% and a specificity of 95% for predicting success after ablation (AUC=0.813; 95% CI: 0.76-0.92; p<0.0001).Conclusion: The presence of MAC, increased LA diameter, the existence of LASEC, low LAAV, and low peak PV systolic wave velocity are parameters that can predict the recurrence of AF after cryoablation.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The purpose of this study was to investigate the factors predicting the maintenance of sinus rhythm in patients with paroxysmal atrial fibrillation (PAF) who underwent cryoablation of the pulmonary veins (PVs). Methods: Fifty-one patients (54.6±10.4 years) with paroxysmal AF who underwent the cryoablation of the PVs were to the prospective trial. The clinical risk factors and echocardiographic parameters [left atrial (LA) diameter, left ventricular ejection fraction and dimensions, left atrial spontaneous echo contrast (LASEC), mitral annulus calcification (MAC), left atrial appendage emptying peak flow velocity (LAAV), and PV flow] were assessed before the cryoablation procedure. Patients with PAF who refused to use any medication because of intolerance or presentation of resistant symptoms, despite the use of at least one antiarrhythmic drug were enrolled to the study, patients with LA/LAA thrombus on echocardiographic examination, severe valvular disease, pericardial fluid, and abnormal thyroid function tests as well as systemic disease were excluded from the study. All parameters were tested for their ability to predict the recurrence of AF during a 1-year follow-up period. Results: During the period of follow-up, AF recurred in 16 of 51 patients (31.3%/year). All significant parameters associated with the recurrence of AF were evaluated in multivariate logistic regression analysis. The presence of MAC (p<0.001) as well as LA diameter (p<0.0001), LAAV of <30 cm/s (p<0.0001), PV flow systolic wave velocity (p<0.0001), and LASEC (p<0.0001) were detected as independent predictors of recurrence. In the receiver operating characteristic analysis, LAAV of >30 cm/s had a sensitivity of 85% and a specificity of 95% for predicting success after ablation (AUC=0.813; 95% CI: 0.76-0.92; p<0.0001).Conclusion: The presence of MAC, increased LA diameter, the existence of LASEC, low LAAV, and low peak PV systolic wave velocity are parameters that can predict the recurrence of AF after cryoablation.

🔖

Cite This Article

GEREDE, D. M., CANDEMİR, B., VURGUN, V. K., ACIBUCA, A., ÖZCAN, Ö. U., GÖKSÜLÜK, H., KERVANCIOĞLU, C., EROL, Ç. (2016). Prediction of recurrence after cryoballoon ablation therapy in patients with paroxysmal atrial fibrillation. The Anatolian Journal of Cardiology, Cilt: 16 - Sayı: 7, 482–488. https://ajindex.com/articles/365425

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Stewart S, Hart CL, Hole DJ, McMurray JJ. Population prevalence incidence, and predictors of atrial fibrillation in the Renfrew/ Paisley study. Heart 2001; 86: 516-21
  2. Haïssaguerre M, Jaïs P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339: 659-66
  3. Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al. 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 2012; 14: 528-606
  4. Fleck T, Wolf F, Bader T, Lehner R, Aigner C, Stix G, et al. Atrial function after ablation procedure in patients with chronic atrial fibrillation using steady-state free precession magnetic resonance imaging. Ann Thorac Surg 2007; 84: 1600-4
  5. Oki T, Tabata T, Yamada H, Wakatsuki T, Fukuda K, Abe M, et al. Evaluation of left atrial filling using systolic pulmonary venous flow velocity measurements in patients with atrial fibrillation. Clin Cardiol 1998; 21: 169-74
  6. Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography: American Society of Echocardiography committee on standards, subcommittee on quantitation of two-dimensional echocardiograms. J Am Soc Echocardiogr 1989; 2: 358-67
  7. Fatkin D, Kelly R, Feneley M. Relations between left atrial appendage blood flow velocity, spontaneous echocardiographic contrast and thromboembolic risk in vivo. J Am Coll Cardiol 1994; 23: 961-9
  8. Schisterman EF, Perkins NJ, Liu A, Bondell H. Optimal cut-point and its corresponding Youden Index to discriminate individuals using pooled blood samples. Epidemiology 2005; 16: 73-81
  9. Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG et al. STOP AF Cryoablation Investigators. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol 2013; 61: 1713-23
  10. Schade A, Langbein A, Spehl S, Barth S, Deneke T, Groschup G, et al. Recurrence of paroxysmal atrial fibrillation after cryoisolation of the pulmonary veins. Is a "redo" procedure using the cryoballoon useful? J Interv Card Electrophysiol 2013; 36: 287-95
  11. Verma