Journals / The Anatolian Journal of Cardiology / 2018 / Cilt: 20 - Sayı: 1

Effect of modified Blalock-Taussig shunt anastomosis angle and pulmonary artery diameter on pulmonary flow

Pages
2–8
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Vertical anastomosis configurations increase the totalPA flow; thus, these configurations are preferable than the leaned configurations.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: This study aimed to identify the best graft-to-pulmonary artery (PA) anastomosis angle measuring pulmonary blood flow, wall shearstress (WSS), and shunt flow.Methods: A tetralogy of Fallot with pulmonary atresia computer model was used to study three different modified Blalock-Taussig shunt (mBTS)anastomosis angle configurations with three different PA diameter configurations.
📊
Key Findings & Data:Velocity and WSS were analyzed, and the flow rates at theright PA (RPA) and left PA (LPA) were calculated.Results: A 4-mm and 8-mm diameter of RPA and LPA, respectively with vertical shunt angle produces the highest total flow.
💡
Conclusion & Impact:Vertical anastomosis configurations increase the totalPA flow; thus, these configurations are preferable than the leaned configurations.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: This study aimed to identify the best graft-to-pulmonary artery (PA) anastomosis angle measuring pulmonary blood flow, wall shearstress (WSS), and shunt flow.Methods: A tetralogy of Fallot with pulmonary atresia computer model was used to study three different modified Blalock-Taussig shunt (mBTS)anastomosis angle configurations with three different PA diameter configurations. Velocity and WSS were analyzed, and the flow rates at theright PA (RPA) and left PA (LPA) were calculated.Results: A 4-mm and 8-mm diameter of RPA and LPA, respectively with vertical shunt angle produces the highest total flow. In the RPA largerdiameter than the LPA configutations, the left-leaning shunt produces the lowest total PA flow whereas in the LPA larger diameter than the RPAconfiguratios, the right-leaning shunt produces the lowest total PA flow. Therefore, the shunt anastomosis should not be leaned through thenarrow side of PA to reach best flow. As the flow inside the shunt increased, WSS also increased due to enhanced velocity gradients.Conclusion: The anastomosis angle between the conduit and PA affects the flow to PA. Vertical anastomosis configurations increase the totalPA flow; thus, these configurations are preferable than the leaned configurations.

🔖

Cite This Article

ARNAZ, A., PİŞKİN, Ş., OĞUZ, G. N., YALÇINBAŞ, Y., PEKKAN, K., SARIOĞLU, C. T. (2018). Effect of modified Blalock-Taussig shunt anastomosis angle and pulmonary artery diameter on pulmonary flow. The Anatolian Journal of Cardiology, Cilt: 20 - Sayı: 1, 2–8. https://ajindex.com/articles/365301

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Kheyfets VO, Rios L, Smith T, Schroeder T, Mueller J, Murali S, et al. Patient-specific computational modeling of blood flow in the pulmonary arterial circulation. Comput Methods Programs Biomed 2015; 120: 88-101. [CrossRef] Piskin S, Unal G, Arnaz A, Sarioglu T, Pekkan K. Tetralogy of Fallot Surgical Repair: Shunt Configurations, Ductus Arteriosus and the Circle of Willis. Cardiovasc Eng Technol 2017; 8: 107-19. [CrossRef] Liu J, Sun QI, Hong H, Sun Y, Liu J, Qian Y, et al. Medical imagebased hemodynamic analysis for modified Blalock-Taussig shunt. J Mech Med Biol 2015; 15: 1-17. [CrossRef] Chaudhari M, Balmer C, Heng JT, Wright J, Stümper O. Usefulness of Blalock-Taussig shunt Doppler flow velocity profiles in the assessment of pulmonary artery pressure and flow. Eur J Echocardiogr 2004; 5: 111-7. [CrossRef] Gedicke M, Morgan G, Parry A, Martin R, Tulloh R. Risk factors for acute shunt blockage in children after modified Blalock-Taussig shunt operations. Heart Vessels 2010; 25: 405-9. [CrossRef] Shibata M, Itatani K, Oka N, Yoshii T, Nakamura Y, Kitamura T, et al. Optimal Graft Size of Modified Blalock-Taussig Shunt for Biventricular Circulation in Neonates and Small Infants. Int Heart J 2015; 56: 533-6. [CrossRef] Fitts MK, Pike DB, Anderson K, Shiu YT. Hemodynamic Shear Stress and Endothelial Dysfunction in Hemodialysis Access. Open Urol Nephrol J 2014; 7(Suppl 1 M5): 33-44.
  2. Peiffer V, Sherwin SJ, Weinberg PD. Does low and oscillatory wall shear stress correlate spatially with early atherosclerosis? A systematic review. Cardiovasc Res 2013; 99: 242-50. [CrossRef] Cunningham KS, Gotlieb AI. The role of shear stress in the pathogenesis of atherosclerosis. Lab Invest 2005; 85: 9-23. [CrossRef] Tanweer O, Wilson TA, Metaxa E, Riina HA, Meng H. A comparative review of the hemodynamics and pathogenesis of cerebral and abdominal aortic aneurysms: lessons to learn from each other. J Cerebrovasc Endovasc Neurosurg 2014; 16: 335-49. [CrossRef] Arora D, Behr M, Pasquali M. A tensor-based measure for estimating blood damage. Artif Organs 2004; 28: 1002-15. [CrossRef] Piskin S, Ündar A, Pekkan K. Computational Modeling of Neonatal Cardiopulmonary Bypass Hemodynamics With Full Circle of Willis Anatomy. Artif Organs 2015; 39: E164-75. [CrossRef] de Zélicourt D, Jung P, Horner M, Pekkan K, Kanter KR, Yoganathan AP. Cannulation strategy for aortic arch reconstruction using deep hypothermic circulatory arrest. Ann Thorac Surg 2012; 94: 614-20.
  3. Dur O, Coskun ST, Coskun K