Journals / Acta Orthopaedica et Traumatologica Turcica / 2016 / Cilt: 50 - Sayı: 4

Dual plating for comparison of various combinations of plate lengths Şxation of humeral shaft fractures: A mechanical

Pages
432–436
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This isan open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The role of plate conŞguration was found inconclusive on the biomechanical effects of theplate size and hole number for dual plate constructions in humeral shaft fractures.
📊
Key Findings & Data:The purpose of thisstudy was to test the biomechanical stability of various dual plate constructions.Methods: Twenty-four left humeri (4th Generation Composite Humerus, Sawbones, MalmEURo, Sweden)with comminuted midshaft humeral fracture were used.
💡
Conclusion & Impact:This isan open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
🔬Design:Research Article
📍Scope:2016 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: The role of plate conŞguration was found inconclusive on the biomechanical effects of theplate size and hole number for dual plate constructions in humeral shaft fractures. The purpose of thisstudy was to test the biomechanical stability of various dual plate constructions.Methods: Twenty-four left humeri (4th Generation Composite Humerus, Sawbones, MalmEURo, Sweden)with comminuted midshaft humeral fracture were used. Four groups of plate constructs were tested:laterallyŞxed 8-hole locking plate and screws were combined with anteriorly locking plates containing0, 4, 6, or 8 holes in groups I, II, III, and IV, respectively. The alterations in axial, bending, and torsionalangles were recorded.Results: There were noŞxation failures during axial, bending, or torsional stiffness testing within theelastic behavior limits. Axial stiffness was highest in Group IV. Torsional stiffness, posterior-to-anteriorbending stiffness, lateral-to-medial bending stiffness, and medial-to-lateral bending stiffness werelowest in Group I.Conclusion: The similar stiffness values for the 8-to-4 hole and 8-to-6 hole plate constructions indicatethat the 8-to-4 hole construction is an option in young adults, while the stiffest 8-to-8 hole combinationmay be an option for osteoporotic patients.© 2016 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. This isan open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

🔖

Cite This Article

KARAKAŞLI, A., BAŞCI, O., ERTEM, F., HAVITÇIOĞLU, H. (2016). Dual plating for comparison of various combinations of plate lengths Şxation of humeral shaft fractures: A mechanical. Acta Orthopaedica et Traumatologica Turcica, Cilt: 50 - Sayı: 4, 432–436. https://ajindex.com/articles/353975

References (3)

  1. Baron JA, Karagas M, Barrett J, et al. Basic epidemiology of fractures of the upper end and lower limb among Americans over 65 years of age. Epidemi ology. 1996;7:612e618. Ring D, Perey BH, Jupiter JB. The functional outcome of ununited fractures of the humeral diaphysis in older patients. J Bone Jt Surg Am. 1999;81:177e190. Patel R, Neu CP, Curtiss S, Fyhrie DP, Yoo B. Crutch weightbearing on commi nuted humeral shaft fractures: a biomechanical comparison of large versus small fragmentŞxation for humeral shaft fractures. J Orthop Trauma. 2011;25: 300e305. Watts A, Weinhold P, Kesler W, Dahners L. A biomechanical comparison of short segment long bone fractureŞxation techniques: single large fragment plate versus 2 small fragment plates. J Orthop Trauma. 2012;26:528e532. Kosmopoulos V, Nana AD. Dual plating of humeral shaft fractures: orthogonal plates biomechanically outperform side-by-side plates. Clin Orthop Relat Res. 2014 Apr;472(4):1310e1317. http://dx.doi.org/10.1007/s11999-013-3379-7. Epub 2013 Nov 12. PubMed PMID: 24218163; PubMed Central PMCID: PMC3940765. Tejwani NC1, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma. 2009 Mar;66(3):795e799. http://dx.doi.org/10.1097/TA.0b013e318181e53c.
  2. Fitzpatrick DC, Doornink J, Madey SM, Bottlang M. Relative stability of con- ventional and locked platingŞxation in a model of the osteoporotic femoral diaphysis. Clin Biomech. 2009;24:203e209. O'Toole RV, Andersen RC, Vesnovsky O, et al. Are locking screws advantageous with plateŞxation of humeral shaft fractures? a biomechanical analysis of synthetic and cadaveric bone. J Orthop Trauma. 2008 NoveDec;22(10): 709e715. http://dx.doi.org/10.1097/BOT.0b013e31818df8cb).
  3. Blum J, Machemer H, Baumgart F, Schlegel U, Wahl D, Rommens PM. Biome- chanical comparison of bending and torsional properties in retrograde intra- medullary nailing of humeral shaft fractures. J Orthop Trauma. 1999 Jun- Jul;13(5):344e350. PubMed PMID: 10406701. Padhye KP, Kulkarni VS, Kulkarni GS, et al. Plating, nailing, externalŞxation, andŞbular strut grafting for non-union of humeral shaft fractures. J Orthop Surg (Hong Kong). 2013 Dec;21(3):327e331. PubMed PMID: 24366794. Foster RJ, Dixon Jr GL, Bach AW, Appleyard RW, Green TM. InternalŞxation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study. J Bone Jt Surg A