📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to analyze the clinical and functional results of hook plateŞxation inNeer type 2 distal clavicle fractures.Methods: We retrospectively analyzed 16 patients (11 males, 5 females) who were diagnosed with Neertype 2 distal clavicle fractures and treated with hook plateŞxation between 2013 and 2014.
📊
Key Findings & Data:Mean agewas 38 (range: 27e61), and mean follow-up time was 14.3 (range: 12e18) months.
💡
Conclusion & Impact:This isan open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
🔬Design:Research Article
📍Scope:2013 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this study was to analyze the clinical and functional results of hook plateŞxation inNeer type 2 distal clavicle fractures.Methods: We retrospectively analyzed 16 patients (11 males, 5 females) who were diagnosed with Neertype 2 distal clavicle fractures and treated with hook plateŞxation between 2013 and 2014. Mean agewas 38 (range: 27e61), and mean follow-up time was 14.3 (range: 12e18) months. Complications seenon radiographs were implant failure and subacromial osteolysis. The clinical results were evaluated withmodiŞed UCLA (University of California Los Angeles) scoring system.Results: Bone union was achieved in all patients at the end of theŞrst 4 months. Mean modiŞed UCLAscore was 32.75 (range 31e35). In 12 patients (68%), the implants had to be removed due to complications. After removal, the complaints regressed and shoulders' range of motion increased.Conclusion: Clinical and radiological results on theŞxation of Neer type 2 distal clavicle fractures with ahook plate are good in terms of fracture union and function. The major disadvantage of the method wasthe requirement of early implant removal due to the hardware related complications and good resultscan be achieved only after plate removal. Optimizing the length of hook plate may lower the rate ofcomplications.Level of evidence: Level IV, Therapeutic study.© 2016 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V. This isan open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

🔖

Cite This Article

ŞÜKÜR, E., ÖZTÜRKMEN, Y., AKMAN, Y. E., GÜNGOR, M. (2016). Clinical and radiological results on the clavicle fractures with a hook plate Şxation of Neer type 2 distal. Acta Orthopaedica et Traumatologica Turcica, Cilt: 50 - Sayı: 5, 489–493. https://ajindex.com/articles/353555

References (2)

  1. McKee MD. Clavicle fractures. In: Bucholz RW, Heckman JD, Court-Brown CM, Tornetta P, eds. Rockwood and Green's Fractures in Adults. 7th ed. Lippincott Williams& Wilkins; 2010:1108e1143. section 2. Robinson CM, Cairns DA. Primary nonoperative treatment of displaced lateral fractures of the clavicle. J Bone Jt Surg Am. 2004;86:778e782. Bisbinas I, Mikalef P, Gigis I, Beslikas T, Panou N, Christoforidis I. Management of distal clavicle fractures. Acta Orthop Belg. 2010;76:145e149. Banerjee R, Waterman B, Padalecki J, Robertson WJ. Management of distal clavicle fractures. J Am Acad Orthop Surg. 2011 Jul;19:392e401. Fann CY, Chiu FY, Chuang TY, Chen CM, Chen TH. Transacromial Knowles pin in the treatment of Neer type 2 distal clavicle fractures. A prospective evaluation of 32 cases. J Trauma. 2004;56:1102e1105. Wu K, Chang CH, Yang RS. Comparing hook plates and Kirschner tension band wiring for unstable lateral clavicle fractures. Orthopedics. 2011 Nov 9;34: e718ee723. http://dx.doi.org/10.3928/01477447-20110922-17. Tiren D, van Bemmel AJ, Swank DJ, van der Linden FM. Hook plateŞxation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview. J Orthop Surg Res. 2012;11:2. http://dx.doi.org/10.1186/1749-799X- 2. Stegeman Sylvia A, Nacak Hakan, Huvenaars Koen HJ, Stijnen Theo, Krijnen Pieta, Schipper Inger B. Surgical treatment of Neer type-2 of the distal clavicle, a meta-analysis. Acta Orthop. 2013;84:184e189. Kashii M, Inui H, Yamamoto K. Surgical treatment of distal clavicle fractures using the clavicular hook plate. Clin Orthop Relat Res. 2006;447:158e164. Muramatsu K, Shigetomi M, Matsunaga T, Murata Y, Taguchi T. Use of the AO hook plate for treatment of unstable fractures of the distal clavicle. Arch Orthop Trauma Surg. 2007;127:191e194. Tan HL, Zhao JK, Qian C, Shi Y, Zhou Q. Clinical results of treatment using a clavicular hook plate versus a T-plate in Neer type II distal clavicle fractures. Orthopedics. 20120725-18. http://dx.doi.org/10.3928/
  2. Meda PV, Machani B, Sinopidis C, Braithwaite I, Brownson P, Frostick SP. Clavicular hook plate for lateral end fractures: a prospective study. Injury.;37:277e283. Renger RJ, Roukema GR, Reurings JC, Raams PM, Font J, Verleisdonk EJ. The clavicle hook plate for Neer type II lateral clavicle fractures. J Orthop Trauma.;23:570e574. Daglar B, Delioglu EUROM, Minareci E, Taflbafl BA, Bayrakci K, Günel U. An alter- nativeŞxation method for the treatment of unstable distal clavi