Journals / Acta Orthopaedica et Traumatologica Turcica / 2021 / Cilt: 55 - Sayı: 1

Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis

Pages
9–15
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additionally,the strength of the materials is increased and implant failure can be minimized by using this technique.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to evaluate the strength of the locking plate and lag screw construct that is applied in two differentworking lengths on the simple distal femur fracture model with a finite element analysis (FEA) method.Methods: From the computerized tomography scan data of a 60-year-old healthy male, the AO/OTA 33A1-type fracture model was simulated;the fracture gap was stabilized with the models of locking plate construct with (groups C and D) or without an interfragmentary lag screw (groupsA and B).
📊
Key Findings & Data:Furthermore, 102-mm plate (groups A and C) and 82-mm plate working lengths (groups B and D) were tested using FEA.
💡
Conclusion & Impact:Additionally,the strength of the materials is increased and implant failure can be minimized by using this technique.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: The aim of this study was to evaluate the strength of the locking plate and lag screw construct that is applied in two differentworking lengths on the simple distal femur fracture model with a finite element analysis (FEA) method.Methods: From the computerized tomography scan data of a 60-year-old healthy male, the AO/OTA 33A1-type fracture model was simulated;the fracture gap was stabilized with the models of locking plate construct with (groups C and D) or without an interfragmentary lag screw (groupsA and B). Furthermore, 102-mm plate (groups A and C) and 82-mm plate working lengths (groups B and D) were tested using FEA. Two loadingconditions (axial compression and torsion) were applied at the center of the femoral head. Construct stiffness, interfragmentary micromotion,and the peak von Mises stress (VMS) on the plate were assessed.Results: Group D provided the highest axial stiffness (1347 N/mm), and group A was the weakest (439 N/mm). With the lag screw, shearmicromotion remained generally low compared with that without the screw for all axial and torsional load levels and for both plate workinglengths, i.e., 0.23 mm with lag screw versus 0.43 mm without lag screw (102 mm working length, 700 N). The percentage decreases of shearmicromotion under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >22% and 73%, respectively; while thosefor the 82-mm working length were >28% and 33%, respectively. The reduction of axial micromotion was observed with the lag screw forall axial load levels as well as for both plate working lengths, i.e., 0.33 mm with lag screw versus 0.87 mm without lag screw (102-mm working length, 700 N). The percentage decreases of axial micromotion under axial loading (350/700/1400 N) for 102 mm and 82 mm workinglengths were >42% and 50%, respectively. The peak VMS on the plate stayed generally low with lag screw compared with without lag screwthroughout all tested load levels, as well as for both plate working lengths, i.e., 124.26 MPa versus 244.39 MPa (102 mm working length, 700N). The percentage decreases of the peak VMS under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >40%and 69%, respectively, while those for the 82-mm working length were >47% and 61%, respectively.Conclusion: The current FEA concludes that in a simple distal femur fracture, adding a lag screw to a locking plate construct providesbetter torsional stability with a 102-mm plate working length and better axial stability with a 82-mm plate working length. Additionally,the strength of the materials is increased and implant failure can be minimized by using this technique.

🔖

Cite This Article

ZHANG, J., WEI, Y., LI, G., WANG, J., XU, Y. (2021). Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis. Acta Orthopaedica et Traumatologica Turcica, Cilt: 55 - Sayı: 1, 9–15. https://ajindex.com/articles/353452

References (15)

  1. Court-Brown CM, Caesar B. Epidemiology of adult fracture: A review. Injury 2006; 37: 691-7
  2. Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 2007; 21: S1-S133
  3. Ehlinger M, Ducrot G, Adam P, Bonnomet F. Distal femur fractures. Surgical techniques and a review of the literature. Orthop Traumatol Surg Res 2013; 99: 353-60
  4. Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma 2004; 18: 488-93
  5. Claes L. Biomechanical principles and mechanobiologic aspects of flexible and locked plating. J Orthop Trauma 2011; 25: S4-S7
  6. Krettek C, Muller M, Miclau T. Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury 2001; 32: SC14-SC23
  7. Tan SLE, Balogh ZJ. Indications and limitations of locked plating. Injury 2009; 40: 683-91
  8. Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 2002; 84: 1093-110
  9. Weight M, Collinge C. Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2 and C3). J Orthop Trauma 2004; 18: 503-08
  10. Ehlinger M, Adam P, Abane L, Arlettaz Y, Bonnomet F. Minimally-invasive internal fixation of extra-articular distal femur fractures using a locking plate: tricks of the trade. Orthop Traumatol Surg Res 2011; 97: 201-05
  11. Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma 2010; 24: 156-62
  12. Gardner MJ, Nork SE, Huber P, Krieg JC. Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study. J Orthop Trauma 2009; 23: 281-7
  13. Linn MS, McAndrew CM, Prusaczyk B, Brimmo O, Ricci WM, Gardner MJ. Dynamic locked plating of distal femur fractures. J Orthop Trauma 2015; 29: 447-50
  14. Chung JY, Cho JH, Kweon HJ, Song HK. The use of interfragmentary positional screw in minimally invasive plate osteosynthesis for simple distal femur fractures in elderly patients: A retrospective, single-centre pilot study. Injury 2016; 47: 2795-9
  15. Horn C, Dobele S, Vester H, Schäffler A, Lucke M, Stöckle U. Combination of interf