Comparison of Six Methods of Central Corneal Thickness Measurement in Healthy Eyes

Pages
7–13
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The overall intraclass correlation coefficient was 0.961 (range: 0.945-0.974) with a 95% confidence interval.Conclusion: All of the CCT measurements obtained using non-contact tono/pachymetry, non-contact specular microscopy, biometry, Scheimpflug-based corneal topography, and OCT were consistent with the USP measurements ofhealthy controls.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: Several methods of measuring central corneal thickness (CCT) have been compared, however, the data are still limited and conflicting.
📊
Key Findings & Data:The CCT of all of the eyes included was measured using 6 different methods.
💡
Conclusion & Impact:The overall intraclass correlation coefficient was 0.961 (range: 0.945-0.974) with a 95% confidence interval.Conclusion: All of the CCT measurements obtained using non-contact tono/pachymetry, non-contact specular microscopy, biometry, Scheimpflug-based corneal topography, and OCT were consistent with the USP measurements ofhealthy controls.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objectives: Several methods of measuring central corneal thickness (CCT) have been compared, however, the data are still limited and conflicting. The aim of this study was to determine the agreement of CCT measurements performed in healthy eyes using ultrasound pachymetry (USP), non-contact tono/pachymetry, specular microscopy, biometry, Scheimpflug-based corneal topography, and optical coherence tomography (OCT).Methods: All of the participants underwent a complete ophthalmological examination. The CCT of all of the eyes included was measured using 6 different methods. The agreement between the methods was analyzed using the meandifference and Bland-Altman analysis based on a 95% limits of agreement.Results: A total of 64 patients with a mean age of 40.96±14.52 years (range: 20-78 years) were included in the study. The mean CCT value was 552.10±35.65 μm, 550.40±35.55 μm, 554.67±35.49 μm, 545.39±34.21 μm, 546.25±35.49 μm, and 552.64±33.59 μm using USP, non-contact tono/pachymetry, non-contact specular microscopy, biometry, Scheimpflugbased corneal topography, and OCT, respectively. The bias values determined by Bland-Altman plots were -1.70, -2.56,6.71, 5.85, and -0.53 for tono/pachymetry, specular microscopy, biometry, topography, and OCT, respectively. OCT demonstrated the lowest bias compared to USP. The overall intraclass correlation coefficient was 0.961 (range: 0.945-0.974) with a 95% confidence interval.Conclusion: All of the CCT measurements obtained using non-contact tono/pachymetry, non-contact specular microscopy, biometry, Scheimpflug-based corneal topography, and OCT were consistent with the USP measurements ofhealthy controls. Larger prospective studies to determine the interchangeability of different methods for CCT measurements in pathological conditions are warranted.

🔖

Cite This Article

İÇEL, E., İÇEL, E., KARAKURT, Y., YILMAZ, H., YILMAZ, H., UĞURLU, A., DEMİR, M. (2021). Comparison of Six Methods of Central Corneal Thickness Measurement in Healthy Eyes. BEYOGLU EYE JOURNAL, Cilt: 6 - Sayı: 1, 7–13. https://ajindex.com/articles/353062

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Mendes MH, Betinjane AJ, Quiroga VA. Correlations between different tonometries and ocular biometric parameters in patients with primary congenital glaucoma. Arq Bras Oftalmol 2013;76:354–6
  2. Tonnu PA, Ho T, Newson T, El Sheikh A, Sharma K, White E, et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 2005;89:851–4
  3. López-Miguel A, Sanchidrián M, Fernández I, Holgueras A, Maldonado MJ. Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery. Graefes Arch Clin Exp Ophthalmol 2017;255:387–92
  4. Almubrad TM, Osuagwu UL, Alabbadi I, Ogbuehi KC. Comparison of the precision of the Topcon SP-3000 P specular microscope and an ultrasound pachymeter. Clin Ophthalmol 2011;5:871–6
  5. Kuerten D, Plange N, Koch E.C, Koutsonas A, Walter P, Fuest M. Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT. Graefes Arch Clin Exp Ophthalmol 2015;253:1105–9
  6. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307–10
  7. Maresca N, Zeri F, Palumbo P, Calossi A. Agreement and reliability in measuring central corneal thickness with a rotating Scheimpflug-Placido system and ultrasound pachymetry. Cont Lens Anterior Eye 2014;37:442–6
  8. Scotto R, Bagnis A, Papadia M, Cutolo CA, Risso D, Traverso CE. Comparison of central corneal thickness measured by standard ultrasound pachymetry, corneal topography, tonopachymetry and anterior segment optical coherence to- mography. J Glaucoma 2017;26:860–5
  9. Maloca PM, Studer HP, Ambrósio R Jr, Goldblum D, Rothenbuehler S, Barthelmes D, Zweifel S, et al. Interdevice variability of central corneal thickness measurement. PLoS One 2018;13;13:e0203884
  10. Binnawi KH, Elzubeir H, Osman E, Abdu M, Abdu M. Central corneal thickness measurement using ultrasonic pachymeter, optical coherence tomography, and TMS-5 topographer. Oman J Ophthalmol 2019;12:15–9
  11. Dogan M, Ertan E. Comparison of central corneal thickness measurements with standard ultrasonic pachymetry and optical devices. Clin Exp Optom 2019;102:126–30
  12. González-Pérez J, Queiruga Piñeiro J, Sánchez García Á, González Méijome JM. Comparison of central corneal thickness measured by standard ultrasound pachymetry, corneal topography, tonopa