Journals / Atmospheric Pollution Research / 2019 / Cilt: 10 - Sayı: 2

Assessment of indoor and outdoor microbial air quality of cafeterias of an educational institute

Pages
531–536
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results showed higher fungal levels as compared to bacterial concentrations for most of the sampling locations.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This study investigated airborne microbial levels of two indoor locations and one outdoor location of threecafeterias (A, B and C) of a university campus.
📊
Key Findings & Data:Microbial air samples were collected during the peak operating hours in duplicateduring months of April and May 2017.
💡
Conclusion & Impact:Results showed higher fungal levels as compared to bacterial concentrations for most of the sampling locations.
🔬Design:Research Article
📍Scope:2017 Verileri
⚙️Variables:Domain Parameters

Özet

This study investigated airborne microbial levels of two indoor locations and one outdoor location of threecafeterias (A, B and C) of a university campus. Sampling locations of cafeteria A and B included closed and semiclosed spaces (both naturally ventilated) while for the case of cafeteria C (facilitated with centralized HVAC),both locations were closed. Microbial air samples were collected during the peak operating hours in duplicateduring months of April and May 2017. Results showed higher fungal levels as compared to bacterial concentrations for most of the sampling locations. Highest bacterial count was observed in the closed area of cafeteria B (mean: 214.7 CFU/$m^3$) and lowest in cafeteria C (mean: 70.5 CFU/$m^3$). Moreover, highest fungal countwas found in semi-closed space of cafeteria A (mean: 525.6 CFU/$m^3$) and lowest in cafeteria C (mean: 44.9 CFU/$m^3$). Bacterial concentration levels were found to be mainly linked with indoor sources while fungal levels wereassociated with outdoor sources. Fungal genera sampled on the monitored sites were identified as Cladosporiumspp. (46%), Geotrichium spp. (8.6%), Ulocladium spp. (8.5%), Alterneria spp. (7.9%), Fuserium spp. (6.6%),Curvularia spp. (3%), Aspergillus spp. (2.4%) and Penicillium spp. (1.3%). Whereas gram positive cocci (90%)were found to be most abundantly prevailing class of bacteria. The most dominant bacterial genera found wereStaphylococcus spp., Kocuria spp., Bacillus spp. and Micrococcus spp.

🔖

Cite This Article

ASIF, A., IQBAL, Z. M., JAHANZAIB, M. (2019). Assessment of indoor and outdoor microbial air quality of cafeterias of an educational institute. Atmospheric Pollution Research, Cilt: 10 - Sayı: 2, 531–536. https://ajindex.com/articles/351326

References (9)

  1. Asif, A., Zeeshan, M., Hashmi, I., Zahid, U., Bhatti, M.F., 2018. Microbial quality assessment of indoor air in a large hospital building during winter and spring seasons. Build. Environ. 135, 68–73.
  2. Awad, A.H., Saeed, Y., Hassan, Y., Fawzy, Y., Osman, M., 2018. Air microbial quality in certain public buildings, Egypt: a comparative study. Atmos. Pollut. Res. 9 (4), 617–626.
  3. Branco, P.T.B.S., Alvim-Ferraz, M.C.M., Martins, F.G., Sousa, S.I.V., 2015. Children's exposure to indoor air in urban nurseries-part I: $CO_2$ and comfort assessment. Environ. Res. 140, 1–9.
  4. Breza-Boruta, B., 2016. The assessment of airborne bacterial and fungal contamination emitted by a municipal landfill site in Northern Poland. Atmos. Pollut. Res. 7 (6), 1043–1052.
  5. Crawford, J.A., Rosenbaum, P.F., Anagnost, S.E., Hunt, A., Abraham, J.L., 2015. Indicators of airborne fungal concentrations in urban homes: understanding the conditions that affect indoor fungal exposures. Sci. Total Environ. 517, 113–124.
  6. Diekema, D.J., Pfaller, M.A., Schmitz, F.J., Smayevsky, J., Bell, J., Jones, R.N., SENTRY Participants Group, 2001. Survey of infections due to Staphylococcus species: frequency of occurrence and antimicrobial susceptibility of isolates collected in the United States, Canada, Latin America, Europe, and the Western Pacific region for the SENTRY Antimicrobial Surveillance Program, 1997–1999. Clin. Infect. Dis. 32 (Suppl. 2), S114–S132. Fernández-Rodríguez, S., Sadyś, M., Smith, M., Tormo-Molina, R., Skjøth, C.A., MayaManzano, J.M., Gonzalo-Garijo, Á., 2015. Potential sources of airborne Alternaria spp. spores in South-west Spain. Sci. Total Environ. 533, 165–176.
  7. Gandara, A., Mota, L.C., Flores, C., Perez, H.R., Green, C.F., Gibbs, S.G., 2006. Isolation of Staphylococcus aureus and antibiotic-resistant Staphylococcus aureus from residential indoor bioaerosols. Environ. Health Perspect. 114 (12), 1859. Genitsaris, S., Stefanidou, N., Katsiapi, M., Kormas, K.A., Sommer, U., Moustaka-Gouni, M., 2017. Variability of airborne bacteria in an urban Mediterranean area (Thessaloniki, Greece). Atmos. Environ. 157, 101–110. Gładyszewska-Fiedoruk, K., 2011. Analysis of stack ventilation system effectiveness in an average kindergarten in north-eastern Poland. Energy Build. 43 (9), 2488–2493.
  8. Griffin, D.W., Westphal, D.L., Gray, M.A., 2006. Airborne microorganisms in the African desert dust corridor over the mid-Atlantic ridge, Ocean Drilling Program, Leg 209. Aerobiologia 22 (3), 211–226.
  9. Haas, D.,