Journals / Atmospheric Pollution Research / 2020 / Cilt: 11 - Sayı: 3

Optimization of a thermal desorption-gas chromatography/mass spectrometry method for characterization of semi-volatile organic compounds in high time resolved PM2.5

Pages
619–629
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Using TD-GCMS for analysis of high time resolved PM2.5 will contribute to the improvement of source apportionment,emission inventories, and global chemistry-climate models.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Organic aerosol (OA) is an important fraction of fine particulate matter.
📊
Key Findings & Data:In this work, we investigated the effect ofthermal desorption-gas chromatography/mass spectrometry (TD-GC-MS) analytical variables on 16 polycyclicaromatic hydrocarbons (PAHs) and 29 n-alkanes.
💡
Conclusion & Impact:Using TD-GCMS for analysis of high time resolved PM2.5 will contribute to the improvement of source apportionment,emission inventories, and global chemistry-climate models.
🔬Design:Modeling & Simulation
📍Scope:2.5 samples
⚙️Variables:Domain Parameters

Özet

Organic aerosol (OA) is an important fraction of fine particulate matter. Most primary OA emissions comprisesemivolatile organic compounds (SVOCs) that are reactive and may partition into particle and vapor phases.Collection of SVOCs in the particle phase at high time resolution reduces positive and negative artifacts, butrequires sensitive analytical techniques for chemical characterization. In this work, we investigated the effect ofthermal desorption-gas chromatography/mass spectrometry (TD-GC-MS) analytical variables on 16 polycyclicaromatic hydrocarbons (PAHs) and 29 n-alkanes. Analytical responses of target compounds were mostly influenced by trap desorption time and GC column pressure. The optimal TD-GC-MS trap desorption conditions were350 °C for 10 min at GC constant pressure mode of 17 psi. Good linearity (R2 > 0.99) was observed for all targetanalytes (with the exception of 6 ring PAHs and C35–C39 n-alkanes). Method detection limits were0.038–0.157 ng m−3 and 0.028–0.355 ng m−3 for PAHs and n-alkanes, respectively. The optimized method wastested on PM2.5 samples collected with the high-volume sampling technique at high temporal resolution of 2 h.Analysis of a sample, followed by analysis of a blank, did not show carryover. The optimized TD-GC-MS methodshowed the capability to resolve diurnal variations of target analytes in high time resolved PM2.5. Using TD-GCMS for analysis of high time resolved PM2.5 will contribute to the improvement of source apportionment,emission inventories, and global chemistry-climate models.

🔖

Cite This Article

FLORES, R. M., MERTOĞLU, E. (2020). Optimization of a thermal desorption-gas chromatography/mass spectrometry method for characterization of semi-volatile organic compounds in high time resolved PM2.5. Atmospheric Pollution Research, Cilt: 11 - Sayı: 3, 619–629. https://ajindex.com/articles/351264

References (10)

  1. Bates, M., Bruno, P., Caputi, M., Caselli, M., de Gennaro, G., Tutino, M., 2008. Analysis of polycyclic aromatic hydrocarbons (PAHs) in airborne particles by direct sample introduction thermal desorption GC/MS. Atmos. Environ. 42, 6144–6151.
  2. Elorduy, I., Elcoroaristizabal, S., Durana, N., García, J.A., Alonso, L., 2016. Diurnal variation of particle-bound PAHs in an urban area of Spain using TD-GC/MS: influence of meteorological parameters and emission sources. Atmos. Environ. 138, 87–98.
  3. Fahey, D., Doherty, S., Hibbard, K., Romanou, A., Taylor, P., 2017. Physical Drivers of Climate Change in Climate Science Special Report: Fourth National Climate Assessment, vol. I. pp. 73–113.
  4. Flores, R.M., Doskey, P.V., 2014. Using multidimensional gas chromatography to group secondary organic aerosol species by functionality. Atmos. Environ. 96, 310–321.
  5. Flores, R.M., Doskey, P.V., 2015. Evaluation of multistep derivatization methods for identification and quantification of oxygenated species in organic aerosol. J. Chromatogr. A 1418, 1–11.
  6. Fushimi, A., Hashimoto, S., Ieda, T., Ochiai, N., Takazawa, Y., Fujitani, Y., Tanabe, K., 2012. Thermal desorption – comprehensive two-dimensional gas chromatography coupled with tandem mass spectrometry for determination of trace polycyclic aromatic hydrocarbons and their derivatives. J. Chromatogr. A 1252, 164–170.
  7. Graham, L.A., Tong, A., Poole, G., Ding, L., Ke, F., Wang, D., Caravaggio, G., Charland, J.- P., MacDonald, P., Hall, A., Cheng, Y., Brook, J.R., 2010. A comparison of direct thermal desorption with solvent extraction for gas chromatography-mass spectrometry analysis of semivolatile organic compounds in diesel particulate matter. Int. J. Environ. Anal. Chem. 90, 511–534.
  8. Guangxing, L., Penner, J.E., Cheng, Z., 2016. How will SOA change in the future? Geophys. Res. Lett. 43, 1718–1726.
  9. Ho, S.S.H., Wang, L., Chow, J.C., Watson, J.G., Xue, Y., Huang, Y., Qu, L., Li, B., Dai, W., Li, L., Cao, J., 2018. Optimization and evaluation of multi-bed adsorbent tube method in collection of volatile organic compounds. Atmos. Res. 202, 187–195.
  10. Huang, L., Bohac, S.V., Chernyak, S.M., Batterman, S.A., 2013. Composition and integrity of PAHs, nitro-PAHs, hopanes, and steranes in diesel exhaust particulate matter. Water, air. Soil Pollut. 224, 1630. Jimenez, J.L., Canagaratna, M.R., Donahue, N.M., Prevot, A.S.H., Zhang, Q., Kroll, J.H., DeCarlo, P.F., Allan, J.D., Coe, H., Ng, N.L., Aiken, A.C., Docherty, K.S., Ulbrich, I.M., Grieshop, A