Journals / İzmir Tepecik Eğitim Hastanesi Dergisi / 2021 / Cilt: 31 - Sayı: 2

Gadolinyum Bazlı Kontrast Maddelerle Çoklu Beyin Manyetik Rezonans Görüntülemesi Yapılan Multipl Skleroz Hastalarının Dentat Çekirdek ve Globus Pallidustaki Sinyal Intensite Değişiklikleri

Signal Intensity Changes in the Dentate Nucleus and Globus Pallidus of Multiple Sclerosis Patients Undergoing Multiple Brain Magnetic Resonance Imaging with Gadolinium-Based Contrast Agents

Pages
195–202
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

T1 ağırlıklı görüntülerdeki SI artışı, kontrastlı MRG incelemelerinin sayısı ile bağlantılı görünmektedir.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Amaç: Gadolinyum bazlı kontrast maddelerin kümülatif dozları ile nükleus dentatus (DN) ve globus pallidustaki (GP) sinyal intensite(SI) artışı arasında ilişkiyi araştırmak Yöntem: Çalışmamız üçüncü basamak hastanemizin radyoloji bölümünde retrospektif olarak gerçekleştirilmiş olup; çok sayıda kraniyal manyetik rezonans görüntülemesi (MRG) yapılmış olan multipl skleroz tanılı 21 olguyu (11 kadın, 10 erkek; ortalama yaş: 39.21 ± 10.24, dağılım: 20-57) içermekteydi.
📊
Key Findings & Data:Kontrastsız T1 ağırlıklı MRG’de DN, pons, GP ve talamustaki ortalama sinyal intensite değerleri dikkate alındı.
💡
Conclusion & Impact:T1 ağırlıklı görüntülerdeki SI artışı, kontrastlı MRG incelemelerinin sayısı ile bağlantılı görünmektedir.
🔬Design:Experimental Field Trial
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Amaç: Gadolinyum bazlı kontrast maddelerin kümülatif dozları ile nükleus dentatus (DN) ve globus pallidustaki (GP) sinyal intensite(SI) artışı arasında ilişkiyi araştırmak Yöntem: Çalışmamız üçüncü basamak hastanemizin radyoloji bölümünde retrospektif olarak gerçekleştirilmiş olup; çok sayıda kraniyal manyetik rezonans görüntülemesi (MRG) yapılmış olan multipl skleroz tanılı 21 olguyu (11 kadın, 10 erkek; ortalama yaş: 39.21 ± 10.24, dağılım: 20-57) içermekteydi. Kontrastsız T1 ağırlıklı MRG’de DN, pons, GP ve talamustaki ortalama sinyal intensite değerleri dikkate alındı. DN sinyal intensitesi, pons sinyal intensitesine, GP sinyal intensitesi ise talamus sinyal intensitesine oranlandı. DN-Pons ve GP-Talamus sinyal intensite oranları ile gadolinyum bazlı kontrast madde uygulamaları arasındaki ilişki, tekrarlı ölçümlerde ANOVA analizi ile saptandı. Bulgular: Hem DN-Pons, hem de GP-Talamus sinyal intensite oranlarındaki artış, daha önceki gadolinyum bazlı kontrast madde uygulamalarıyla anlamlı bir korelasyon gösterdi (her ikisi için de p<0.001). Hastaların ilk ve son MRG incelemeleri arasında, DN-Pons ve GP-Talamus sinyal intensite oranlarında ise belirgin artış saptandı (her ikisi için p<0.001). Sonuç: Bulgularımız, MS hastalarının DN ve GP’sindeki SI artışı ile gadolinyum bazlı kontrast maddelerle yapılan MRG incelemeleri arasındaki ilişkiyi desteklemektedir. T1 ağırlıklı görüntülerdeki SI artışı, kontrastlı MRG incelemelerinin sayısı ile bağlantılı görünmektedir.

Özet

Objective: To investigate the correlation between cumulative doses of gadolinium-based contrast agents and increased signal intensity (SI) in the dentate nucleus (DN) and globus pallidus (GP). Methods: Our retrospective trial involved 21 multiple sclerosis patients (11 women, 10 men; mean age: 39.21±10.24, range: 20 to 57 years) who underwent a serial number of multiple cranial magnetic resonance imaging (MRI) examinations in the radiology department of our tertiary care center. Average signal intensities on the DN, pons, GP and thalamus on unenhanced T1-weighted magnetic resonance images were taken into account. The signal intensity in the DN was proportioned to the signal intensity in the pons, whereas the signal intensity in GP to the signal intensity in the thalamus. Any relationship between the DN-to-pons or GP-to-thalamus signal intensity ratios and previous gadolinium-based contrast administrations was sought by means of repeated measures ANOVA. Results: Increases in both DN-to-pons and GP-to-thalamus signal intensity ratios displayed a significant correlation with previous administrations of gadolinium-based contrast agents (p<0.001 for both). A remarkable increase was detected in DN-to-pons and GP-to-thalamus signal intensity ratios between the first and last MRI examinations (p<0.001 for both). Conclusion: Our results support the association between increase in the SI of the DN and GP to the number of gadolinium-enhanced MRI scans in MS patients. The increase in T1 SI seems to be linked with the number of enhanced MRI scans.

🔖

Cite This Article

ÇEKDEMİR, Y. E., KARABAY, N. (2021). Gadolinyum Bazlı Kontrast Maddelerle Çoklu Beyin Manyetik Rezonans Görüntülemesi Yapılan Multipl Skleroz Hastalarının Dentat Çekirdek ve Globus Pallidustaki Sinyal Intensite Değişiklikleri. İzmir Tepecik Eğitim Hastanesi Dergisi, Cilt: 31 - Sayı: 2, 195–202. https://ajindex.com/articles/347805

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Traboulsee A, Simon JH, Stone L, Fisher E, Jones DE, Malhotra A, et al. Revised Recommendations of the Consortium of MS Centers Task Force for a Standardized MRI Protocol and Clinical Guidelines for the Diagnosis and Follow-Up of Multiple Sclerosis. AJNR Am J Neuroradiol. 2016
  2. [CrossRef] 2. Malhotra A, LeSar B, Wu X, Durand D, Das N, Anzai Y, et al. Progressive T1 shortening of the dentate nucleus in patients with multiple sclerosis: result of multiple administrations of linear gadolinium contrast agents versus intrinsic disease. AJR Am J Roentgenol. 2018
  3. [CrossRef] 3. Giesel F, Mehndiratta A, Essig M. High-relaxivity contrastenhanced magnetic resonance neuroimaging: a review. Eur Radiol. 2010
  4. [CrossRef] 4. Sieber MA, Pietsch H, Walter J, Haider W, Frenzel T, Weinmann HJ. A preclinical study to investigate the development of Nephrogenic Systemic Fibrosis: a possible role for gadoliniumbased contrast media. Investig Radiol. 2008
  5. [CrossRef] 5. Sieber MA, Lengsfeld P, Frenzel T, Golfier S, Schmitt-Willich H, Siegmund F, et al. Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in-vivo and to trigger nephrogenic systemic fibrosis-like lesions. Eur Radiol. 2008
  6. [CrossRef] 6. Kanda T, Ishii K, Kawaguchi K, Kitajima K, Takenaka D. High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weightedMR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology 2014
  7. [CrossRef] 7. McDonald RJ, McDonald JS, Kallmes DF, Jentoft ME, Paolini MA, Murray DL, et al. Intracranial gadolinium deposition after contrast-enhanced MR imaging. Radiology 2015
  8. [CrossRef] 8. Quattrocchi CC, Mallio CA, Errante Y, Cirimele V, Carideo L, Ax A, et al. Gadodiamide and dentate nucleus T1 hyperintensity in patients with meningioma evaluated by multiple follow-up contrast-enhanced magnetic resonance examinations with no systemic interval therapy. Invest Radiol. 2015
  9. [CrossRef] 9. Radbruch A, Weberling LD, Kieslich PJ, Eidel O, Burth S, Kickingereder P, et al. Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent. Radiology 2015
  10. [CrossRef] 10. Kanda T, Osawa M, Oba H, Toyoda K, Kotoku J, Haruyama T, et al. High signal intensity in dentate nucleus on unenhanced T1-weighted MR images: associat