Journals / Mikrobiyoloji Bülteni / 2016 / Cilt: 50 - Sayı: 3

Investigation of the Correlation Between Anti-HCV Levels (S/Co) with HCV-RNA in the Diagnosis of Hepatitis C Virus (HCV) Infection

Hepatit C Virus (HCV) Enfeksiyonunun Tanısında Anti-HCV Düzeyi (S/Co) ile HCV-RNA Arasındaki Korelasyonun Araştırılması

Pages
508–510
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Based on the data of this study it became evident that further EIA testing is not required if the S/Co value is >= 5.0, however if the S/Co value is less than 5.0, then further clinical analysis and revaluation of the patient is required.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Detection of borderline and/or low positive anti-HCV results by enzyme immunoassay (EIA) leads to severe problems in routine laboratories and needs confi rmation with nucleic acid amplifi cation tests which can increase the cost.
📊
Key Findings & Data:In EIA tests, if the ratio of sample to cut-off (S/Co) is >= 1, the sample is accepted as positive according to the manufacturers' instructions.
💡
Conclusion & Impact:Based on the data of this study it became evident that further EIA testing is not required if the S/Co value is >= 5.0, however if the S/Co value is less than 5.0, then further clinical analysis and revaluation of the patient is required.
🔬Design:Research Article
📍Scope:2011 Verileri
⚙️Variables:Domain Parameters

Abstract

Detection of borderline and/or low positive anti-HCV results by enzyme immunoassay (EIA) leads to severe problems in routine laboratories and needs confi rmation with nucleic acid amplifi cation tests which can increase the cost. In EIA tests, if the ratio of sample to cut-off (S/Co) is >= 1, the sample is accepted as positive according to the manufacturers' instructions. Although over the last decade the application of S/Co values have also applied to HCV-RNA readings, the current study aims to determine whether the S/Co value is adequate and applicable for the anti-HCV EIA test, and to determine whether a correlation exists between HCV-RNA and HCV infections. A total of 658 cases (402 female, 256 male; mean age: 49.4 ± 17.0 years) who were found anti-HCV positive between January 2011-July 2013 were included in the study. Anti-HCV tests were performed by chemiluminescent EIA (Architect i2000SR, Abbott, USA and LiaisonXL Murex, DiaSorin, Italy) and HCV-RNA by real-time PCR (Cobas Ampliprep/ Cobas TaqMan HCV, Roche, USA). The mean S/Co value of the cases was 7.3 ± 4.8 (range: 1.00-17.59) and mean HCV-RNA value was 2.3x105 ± 2.1x106 copies/ml. When the anti-HCV S/Co value of varying ranges was compared with HCV-RNA readings a particular trend was noted. In the anti-HCV S/Co values of 1.0-4.0; 4.1-7.0; 7.1-10.0; 10.1-13.0; 13.1-16.0 and ³16.1, HCV-RNA positivity rates were detected as 1.9%, 24.7%,37.1%, 46.7%, 56.4% and 75%, respectively. Statistical analysis indicated an intermediate positive correlation (r= 0.454) between anti-HCV ve HCV-RNA readings (p= 0.000). An adequate S/Co value was accepted as 5.0 based on the ROC analysis, and this value gave a performance confi dence level of 95.6% when determining whether a patient is HCV positive. Based on the data of this study it became evident that further EIA testing is not required if the S/Co value is >= 5.0, however if the S/Co value is less than 5.0, then further clinical analysis and revaluation of the patient is required.

🔖

Cite This Article

ŞANLIDAĞ, T., AKÇALI, S., ECEMİŞ, T., SÜER, K., DÜNDAR, P. E., ARIKAN, A., GÜVENİR, M., GÜLER, E. (2016). Investigation of the Correlation Between Anti-HCV Levels (S/Co) with HCV-RNA in the Diagnosis of Hepatitis C Virus (HCV) Infection. Mikrobiyoloji Bülteni, Cilt: 50 - Sayı: 3, 508–510. https://ajindex.com/articles/298434

References (6)

  1. World Health Organization. Hepatitis C. Available at: http://www.who.int/mediacentre/factsheets/ fs164/en/ Messina JP, Humphreys I, Flaxman A, et al. Global distribution and prevalence of hepatitis C virus genotypes. Hepatology 2015; 61(1): 77-87.
  2. Köse Ş, Ece G, Şamlıoğlu P, Topaloğlu S. Tepecik Eğitim ve Araştırma Hastanesi'nde düşük düzeyde anti- hepatit C pozitifl iği saptanan örneklerin HCV RNA düzeylerinin değerlendirilmesi. Turk Hij Den Biyol Derg 2011; 68(4): 191-6.
  3. Ecemiş T, Akçalı S, Erbay Dündar P, Şanlıdağ T. HCV enfeksiyonu tanısında anti-HCV testi ve eşik değer. Turkiye Klinikleri J Med Sci 2012; 32(6): 1648-52.
  4. Güler E, Güvenir M, Arıkan A, Uncu M, Aykaç A, Süer K. KKTC'deki HBV, HCV ve HIV seroprevalansının 3 yıllık değerlendirilmesi. İnfeksiyon Dünyası Çalıştayı, 20-23 Mart 2014. Çalıştay Kitabı, s: 182, P141. Erişim: http://calistay.infeksiyondunyasi.org/global/book/ Infeksiyon_Dunyasi_Calistayi_Kongre_Kitabi.pdf Sayan M, Meriç M, Mutlu B, Çelebi S, Willke A. Mikropartikül enzim immunoassay ile düşük titrede saptanan anti-HCV pozitifl iği hepatit C enfeksiyonunun tanısında kullanılabilir mi? Mikrobiyol Bul 2006; 40(1-2):81-4.
  5. Uzun B, Er H, Güngör S, Şener AG, Kaya S. The evaluation of recombinant immunoblot assay (RIBA) and HCV-RNA test results in patients with low titer anti-HCV positivity. J Clin Exp Invest 2014; 5(4): 553-6.
  6. Yakup G, Toyran A, Aksoy A, Coşkun FA, Sezer A. Ankara Numune Eğitim ve Araştırma Hastanesi'ne başvuran hastaların ve kan donörlerinin hepatit ve HIV seroprevalansının belirlenmesi ve anti-HCV pozitif hastaların HCV RNA seviyelerinin değerlendirilmesi. Viral Hepatit Derg 2013; 19(3): 131-5.