Journals / MN Kardiyoloji / 1998 / Cilt: 5 - Sayı: 2

The assesment of left ventricular systolic function with Q-V peak, corrected Q-V peak and other systolic time intervals

Sol ventrikül sistolik fonksiyonunun noninvazif değerlendirilmesinde Q-V peak, düzeltilmiş Q-V peak ve diğer sistolik zaman aralıklarının kullanımı

Pages
129–132
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a consequence of the study, we concluded that the QVP like the other systolic time intervals, can be used reliably at present and ü is a safe, method to be choosen, particulary in patients with a poor echogen

📌 3 Key Takeaways

🎯
Objective & Hypothesis:One hundred-four cases underwent coronary angiography were included in our study to estimate the role and validity of some systolic time intervals defined recently such as QVP and corrected QVP in determining the left ventriculer performance.
📊
Key Findings & Data:The ejection fraction derived from left ventriculography as an indicator of the left ventricule performance was used as a comparison tool.
💡
Conclusion & Impact:As a consequence of the study, we concluded that the QVP like the other systolic time intervals, can be used reliably at present and ü is a safe, method to be choosen, particulary in patients with a poor echogen
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

One hundred-four cases underwent coronary angiography were included in our study to estimate the role and validity of some systolic time intervals defined recently such as QVP and corrected QVP in determining the left ventriculer performance. The preejection period/ left ventricular ejection time (PEP/LVET ) ratio and Q - V peak (QVP) and the corrected QVP durations of the cases were measured. The ejection fraction derived from left ventriculography as an indicator of the left ventricule performance was used as a comparison tool. The PEP/LVET ratio and the QVP duration were shown to correlate well with the ejection fraction , whereas the QVP corrected for heart rate, although significant, was found to exhibit a slight correlation, with the ejection fraction. Thus, it was concluded thai the QVP should not be necessarily corrected for heart rate. As a consequence of the study, we concluded that the QVP like the other systolic time intervals, can be used reliably at present and ü is a safe, method to be choosen, particulary in patients with a poor echogen

Özet

Sistolik zaman aralıkları içerisinde diğerlerine göre daha yakın zamanda tarif edilmiş olan QV-Peak ( QVP ) ve kalp hızına göre düzeltilmiş QVP' in sol ventrikül performansının belirlemesindeki geçerliliğini belirlemeyi amaçlayan çalışmamıza, değişik nedenlerle, koroner anjiografi uygulanan 104 vaka alınmıştır. Çalışmaya dahil edilen olguların QVP, düzeltilmiş QVP süreleri ve preejeksiyon periyot / sol ventrikül ejeksiyon zamanı (PEP/LVET ) oram ölçüldü. Ayrıca bu olgularda sol ventrikül performansının göstergesi olarak sol ventrikülografıden elde edilen ejeksiyon fraksiyonu karşılaştırma aracı olarak hesaplandı. QVP ve PEP/LVET ' in ejeksiyon fraksiyonu ile iyi bir ilişki gösterdiği, düzeltilmiş QVP nin ise anlamlı olmakla beraber zayıf ilişki gösterdiği belirlendi. Böylece QVP nin kalp hızına göre düzeltilmesinin gerekmediği sonucuna varıldı. Çalışmanın sonucunda QVP'in de diğer sistolik zaman aralıkları gibi günümüz şartlarında da güvenle kullanılabileceği ve özellikle ekojenitesi yeterli olmayan hastalarda seçilebilecek güvenli bir yöntem olduğu sonucuna varıldı.

🔖

Cite This Article

GÜRLERTOP, H. Y., EROL, M. K., BOZKURT, E., KARAKELLEOĞLU, Ş., ATEŞAL, S., ŞENOCAK, H., ALP, N. (1998). The assesment of left ventricular systolic function with Q-V peak, corrected Q-V peak and other systolic time intervals. MN Kardiyoloji, Cilt: 5 - Sayı: 2, 129–132. https://ajindex.com/articles/298044