Journals / MN Kardiyoloji / 2017 / Cilt: 24 - Sayı: 2

Catastrophic Vascular Access Site Complications Observed During Carotid Artery Stenting in a Bovine Aortic Arch Patient

Bovine Aortik Arkusu Olan Bir Hastada Karotid Arter Stentlemesi Esnasında Görülen Katastrofik Vasküler Giriş Yeri Komplikasyonları

Pages
84–86
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Herein, we tried to present a symptomatic case of carotid artery stenting which was complicated by catastrophic radial artery avulsion and vascular closure device-related femoral artery occlusion.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Stenting of carotid arteries with proper cerebral protection method via femoral or radial access is the preferred therapeutic choice for the last decade.
📊
Key Findings & Data:Stenting of carotid arteries with proper cerebral protection method via femoral or radial access is the preferred therapeutic choice for the last decade.
💡
Conclusion & Impact:Herein, we tried to present a symptomatic case of carotid artery stenting which was complicated by catastrophic radial artery avulsion and vascular closure device-related femoral artery occlusion.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Stenting of carotid arteries with proper cerebral protection method via femoral or radial access is the preferred therapeutic choice for the last decade. Herein, we tried to present a symptomatic case of carotid artery stenting which was complicated by catastrophic radial artery avulsion and vascular closure device-related femoral artery occlusion.

Özet

Uygun koruma metodu ile femoral ya da radyal arter girişimi yoluyla yapılan karotid arter stentlemesi son on yıldır uygulanan güncel te-davi yöntemidir. Bu olguda katastrofik radyal arter avulsiyonu ve femoral kapama cihazına bağlı femoral arter tıkanması ile komplike olan semptomatik karotid arter darlığında stentleme işlemini sunmayı amaçladık.

🔖

Cite This Article

VURUŞKAN, E., SARAÇOĞLU, E., DÜZEN, İ. V., KETENCİLER, S. (2017). Catastrophic Vascular Access Site Complications Observed During Carotid Artery Stenting in a Bovine Aortic Arch Patient. MN Kardiyoloji, Cilt: 24 - Sayı: 2, 84–86. https://ajindex.com/articles/297222

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (6)

  1. Alkhouli M, Cohen HA, Bashir R. Radial artery avulsion- a rare complication of transradial catheterization. Catheter Cardiovasc Interv 2015;85:32-4
  2. Arzamendi D, Romeo P, Gosselin G. Radial artery avulsion: a rare complication of percutaneous coronary interven-tion. Rev Esp Cardiol 2011;64:2
  3. Gan HW, Bhasin A, Wu CJ. Transradial carotid stenting in a patient with bovine arch anatomy. Catheter Cardiovasc Interv 2010;75:540-3
  4. Shaw JA, Gravereaux EC, Eisenhauer AC. Carotid stenting in the bovine arch. Catheter Cardiovasc Interv 2003;60:566-9
  5. Yeni H, Axel M, Örnek A, Butz T, Maagh P, Plehn G. Clinical and Subclinical Femoral Vascular Complications of Deployment of two Different Vascular Closure Devices or Manual Compression in the Setting of Coronary Intervention. Int J Med Sci 2016;13:255-9
  6. Fargen KM, Velat GJ, Lawson MF, Rithie CA, Firment C, Hoh BL et al. Occurence of angiographic femoral artery compli-cations after vascular closure with Mynx and Angioseal. J Neurointerv Surg 2013;5:161-4.