Journals / MN Oftalmoloji / 2005 / Cilt: 12 - Sayı: 1

Comparison of change in capsulorhexis size in pseudoexfoliation patients after IOL implant with polymethylmethacrylate or acrylic haptic lenses

Psödoeksfoliasyon sendromlu hastalarda polimetilmetakrilat ve akrilik haptikli lens implantasyonundan sonra kapsüloreksis boyutundaki değişiklik

Pages
6–9
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusıon: In small series of pseudoexfoliation patients, single piece acrylic lens shares the same dynamic properties with PMMA haptic lens over anterior and posterior capsule opacity.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: To determine the effect of two similar acrylic lenses except their haptics on the capsulorhexis size in pseudoexfoliation patients during the 2-3 months postoperatively.
📊
Key Findings & Data:Materials and Methods: In a total of 13 patients, one-piece (monoblock) Acrysof SA-60 was implanted to 7 eyes and Sensar AR-40e (acrylic optic with polymethylmethacrylate-PMMA haptic) to 8 eyes.
💡
Conclusion & Impact:Conclusıon: In small series of pseudoexfoliation patients, single piece acrylic lens shares the same dynamic properties with PMMA haptic lens over anterior and posterior capsule opacity.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Eksfoliasyon sendromu · Lens implantasyonu · göz içi

Abstract

Purpose: To determine the effect of two similar acrylic lenses except their haptics on the capsulorhexis size in pseudoexfoliation patients during the 2-3 months postoperatively. Materials and Methods: In a total of 13 patients, one-piece (monoblock) Acrysof SA-60 was implanted to 7 eyes and Sensar AR-40e (acrylic optic with polymethylmethacrylate-PMMA haptic) to 8 eyes. Capsulorhexis opening was pictured digitally during the operation, postoperatively 3rd week and 2-3rd month. Posterior capsule opacity was also evaluated. Results: During the 2-3 month of follow-up, there was no statistically significant difference between two lenses in regard to capsulorhexis size as well as posterior capsule opacity. Conclusıon: In small series of pseudoexfoliation patients, single piece acrylic lens shares the same dynamic properties with PMMA haptic lens over anterior and posterior capsule opacity.

Özet

Amaç: Psödoeksfoliasyon sendromlu hastalarda haptikleri dışında benzer özelliklere sahip iki akrilik lensin postoperatif 2-3 ay süresince kapsül boyutunda oluşturduğu değişikliği saptamak Gereç ve Yöntem: Toplam 13 hastada 7 göze tek parça akrilik lens olan Acrysof SA-60 ve 8 göze akrilik optiğe ve polimetilmetakrilat (PMMA) haptiğe sahip Sensar AR-40e yerleştirildi. Kapsüloreksis açıklığı ameliyat sırasında, ameliyattan sonra 3. hafta ve 2-3. ayda dijital fotoğraflarla tespit edildi. Arka kapsül opasitesi de ayrıca değerlendirildi. Bulgular: Takip süresince ne kapsuloreksis boyutu ne de arka kapsül opasitesi yönünden her iki lens arasında istatiksel olarak anlamlı fark bulunmadı. Sonuç: Sınırlı sayıdaki psödoeksfoliasyonlu hasta serimizde tek parça akrilik lens PMMA haptikli akrilik lensle ön ve arka kapsül üzerinde aynı dinamik özellikler göstermektedir.

🔖

Cite This Article

IRAK, İ., CRANDALL, A. (2005). Comparison of change in capsulorhexis size in pseudoexfoliation patients after IOL implant with polymethylmethacrylate or acrylic haptic lenses. MN Oftalmoloji, Cilt: 12 - Sayı: 1, 6–9. https://ajindex.com/articles/296058

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Davison JA. Capsule contraction syndrome. J Cataract Refract Surg 1993; 19:582-9.
  2. Hansenr SO, Crandall AS, Olson RJ. Progressive constriction of the anterior capsule opening following intact capsulorhexis. J Cataract Refract Surg 1993; 19:77-82.
  3. Hayashi H, Hayashi K, Nakao F, Hayashi F. Area reduction in the antreior capsule opening in eyes of diabetes mellitus patients. J Cataract Refract Surg 1998; 24:1105-10.
  4. Gimbel HV, Neuhann T. Development, advantages, and the methods of continuous circular capsulorhexis technique. J Cataract Refract Surg 1990; 16:31-7.
  5. Joo-J-K, Shin J-A, Kim J-H. Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation. J Cataract Refract Surg 1996; 22:585-90.
  6. Salzman J, Khaw PT, Laidlaw A. Choroidal effusions and hypotony caused by severe anterior lens capsular contraction after cataract surgery. Am J Ophthalmol 2000; 29:253-4.
  7. Hara T, Hara T, Kojima M, Nakaizumi H, Yamamura T, Ssaki K. Specular microscopy of the anterior lens capsule after endocapsular lens implantation. J Cataract Refract Surg 1988; 14:533-40.
  8. Cochener B, Jacq P-L, Colin J. Capsule contraction after continuous curvilinear capsulorhexis. Poly (met.hylmethacrylate) versus silicone intraocular lenses. J Cataract Refract Surg 1999; 25:1362-9.
  9. Linnola RJ, Werner L, Pandey SK, Escolar-Gomei M, Znoiko SL, Apple DJ. Adhesion af fibronectin, vitronec'tin, laminin and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes. Part 2:explanted intraocular lenses. J Cataract Refract Surg 2000; 26:1807-18. Lane S. Acrysof one piece biomechanics- A laborotary study: Presentation at Alcon Winter Course 2002,
  10. Park City, Utah. Sickenberg M, Gonvers M, Mell GV. Change in capsulorhe­ xis size with four foldable loop-haptic lenses over 6 moths. J Cataract Refract Surg 1998; 24:925-30.
  11. Park TK, Chung SK, Back NH. Changes in the area of the anterior capsule opening after intraocular lens implantation. J Cataract Refract Surg 2002; 28:1613-7.
  12. Gallagher SP, Pavilac MA. Risk factors for anterior capsule contraction syndrome with polyprolene or poly (methylmethacrylate) haptics. J Cataract Refract Surg 1999; 25:1356-61. Nishi O. Intercapsular cataract surgery with lens epithelial cell removal. Part II.effect on prevention of fibrous reaction. J Cataract Refract Surg 1989; 15:301-3.