Journals / Niğde Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi / 2017 / Cilt: 6 - Sayı: 2

OPTIMAL DAMPER PLACEMENT TO PREVENT POUNDING OF ADJACENT STRUCTURES CONSIDERING A TARGET DAMPING RATIO AND RELATIVE DISPLACEMENT

BİTİŞİK NİZAM YAPILARIN ÇARPIŞMASINI ÖNLEMEK İÇİN BİR HEDEF SÖNÜM ORANI VE RÖLATİF DEPLASMAN DÜŞÜNÜLEREK OPTİMUM SÖNÜMLEYİCİ YERLEŞİMİ

Pages
581–592
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The appropriate number and locations of linear viscous dampers between adjacent structures are determined, and their effects on structural behaviour are evaluated.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, viscous dampers are optimally placed between two adjacent structures with the aim of preventing pounding.
📊
Key Findings & Data:Two 4-storey adjacent shear-building models are used in numerical examples to validate the proposed method.
💡
Conclusion & Impact:The appropriate number and locations of linear viscous dampers between adjacent structures are determined, and their effects on structural behaviour are evaluated.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Çekiçleme · hedef sönüm oranı · ek sönümleyiciler

Abstract

In this study, viscous dampers are optimally placed between two adjacent structures with the aim of preventing pounding. Governing equations are derived in time domain for the optimization problem. Target damping ratios are obtained for the coupled system and used as active constraints in the numerical optimization stage. The damping coefficients of the dampers are chosen as design variables, and the sum of the damping coefficients is minimized under the constraints. An algorithm featuring numerical optimization and time history analysis is put forward to test the candidate optimal design under the earthquake loads of interest. The relative displacements are checked at all storey levels to ensure that they remain below the target values. Two 4-storey adjacent shear-building models are used in numerical examples to validate the proposed method. The appropriate number and locations of linear viscous dampers between adjacent structures are determined, and their effects on structural behaviour are evaluated.

Özet

Bu çalışmada, bitişik nizam iki yapı arasına, sönümleyiciler çarpışmayı önlemek için optimum olarak yerleştirilir. Optimizasyon problemi için yönetici denklemler zaman tanım alanında türetilir. Hedef sönüm oranı girişimli sistem için bulunur ve sayısal optimizasyon aşamasında aktif kısıtlamalar kullanılır. Sönümleyicilerin sönüm katsayıları tasarım değişkeni olarak seçilir ve sönüm katsayılarının toplamı kısıtlamalar altında minimize edilir. Deprem yükleri altında aday optimum tasarımı test etmek için zaman tanım alanında analizleri ve sayısal optimizasyonu içeren bir algoritma gösterilir. Bütün katlarda rölatif deplasmanların hedef değerlerin altına düşüp düşmediği kontrol edilir. Amaçlanan metodun geçerliliğini göstermek için 4 katlı bitişik nizam kayma çerçeveleri sayısal örnek olarak kullanılır. Bitişik yapıların arasına lineer viskoz sönümleyicilerin uygun yerleri ve sayıları hesaplanır ve onların yapısal davranış üzerindeki etkileri araştırılır.

🔖

Cite This Article

AYDIN, E., DİKMEN, M., ÖZTÜRK, B. (2017). OPTIMAL DAMPER PLACEMENT TO PREVENT POUNDING OF ADJACENT STRUCTURES CONSIDERING A TARGET DAMPING RATIO AND RELATIVE DISPLACEMENT. Niğde Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 6 - Sayı: 2, 581–592. https://ajindex.com/articles/290373

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. ANAGNOSTOPOULOS, S.A., “Earthquake Induced Pounding: State of the Art. Procc 10th European Conference on Earthquake Engineering”, Rotterdam, Nederland, 897-905, 1995
  2. KASAI, K., JAGIASI, A.R., JENG, V., “Inelastic Vibration Phase Theory for Seismic Pounding Mitigation”, Journal of Structural Engineering, 122(10), 1136-1146, 1996
  3. PENZIEN, J., “Evaluation of Building Separation Distance Required to Prevent Pounding During Strong Earthquakes”, Earthquake Engineering and Structural Dynamics, 26(8), 849-858, 1997
  4. ROSENBLUETH, E., MELI, R., “The 1985 Earthquake: Cause and Effects in Mexico City”, Concrete Int., ACI, 8(5), 23-24, 1986
  5. ANAGNASTOPOULOS, S.A., “Pounding of Buildings in Series during Earthquakes”, Earthquake Engineering and Structural Dynamics, 16(3), 443-456, 1988
  6. STAVROULAKIS, G.E., ABDALLA, K.A., “Contact between Adjacent Structures”, Journal of Structural Engineering, 117(10), 2838-2850, 1991
  7. JENG, V., KASAI, K., MAISON, B.F., “A Spectral Difference Method to Estimate Building Separations to Avoid Pounding”, Earthquake Spectra, 8(2), 201-223, 1992
  8. LIN, J.H., “Separation Distance to Avoid Seismic Pounding of Adjacent Buildings”, Earthquake Engineering and Structural Dynamics, 26, 395-403, 1997
  9. VALLES, R.E., REINHORN, A.M., “Evaluation, Prevention and Mitigation of Pounding Effects in Building Structures”, Report No NCEER-97-0001, National Center for Earthquake Engineering Res., State University of New York, Buffalo, N.Y., 1997
  10. LUCO, J.E., DE BARROS, F.C.P., “Optimal Damping between Two Adjacent Elastic Structures”, Earthquake Engineering and Structural Dynamics, 27, 649-659, 1998
  11. ZHANG, W.S., XU, Y.L., “Dynamic Characteristics and Seismic Response of Adjacent Buildings Linked by Discrete Dampers”, Earthquake Engineering and Structural Dynamics, 28, 1163-1185, 1999
  12. ABDULLAH, M.M., HANIF, J.H., RICHARSON, A., SOBANJO, J., “Use of a Shared Tuned Mass Damper (STMD) to Reduce Vibration and Pounding in Adjacent Structures”, Earthquake Engineering and Structural Dynamics, 30, 633-651, 2001
  13. LIN, H., WENG, C.C., “Probability Analysis of Seismic Pounding Adjacent Buildings”, Earthquake Engineering and Structural Dynamics, 30, 1539-1557, 2001
  14. ZU, H.P., XU, Y.L., “Optimum Parameters of Maxwell Model Defined Damper Used to Link Adjacent Structures”, Journal of Sound and Vibration, 279, 253-274, 2005
  15. ZHU, H.P., WEN, Y., IEMURA, H., “A Study on Interaction Control for Seismic Respons