Journals / Medical Network Klinik Bilimler ve Doktor / 2004 / Cilt: 10 - Sayı: 3

The problem of perforation in gloves during plastic surgery operations

Plastik cerrahi operasyonları esnasında eldiven delinme sorunu

Pages
292–295
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results: Perforation rates of surgeons were 26.41% (28.57% in consultants and 24% in residents), it was found to be 19.49% in 1. assistants.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Gloves are perforated frequently during plastic surgery operations and many of them are unrecognized.
📊
Key Findings & Data:Material and Method: In the present study, 224 gloves, used in 66 operations, were compared with 140 control gloves with respect to hidden perforations.
💡
Conclusion & Impact:Results: Perforation rates of surgeons were 26.41% (28.57% in consultants and 24% in residents), it was found to be 19.49% in 1. assistants.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Zaman faktörleri · Eldivenler · cerrahi

Abstract

Objective: Gloves are perforated frequently during plastic surgery operations and many of them are unrecognized. They produce an important risk of transmission of viral infections, particularly Hepatitis B, Hepatitis C and HIV. Material and Method: In the present study, 224 gloves, used in 66 operations, were compared with 140 control gloves with respect to hidden perforations. Results: Perforation rates of surgeons were 26.41% (28.57% in consultants and 24% in residents), it was found to be 19.49% in 1. assistants. The rates of glove perforation is 13.88%, 18.60% and 37.87% in operations lasting less than 60 minutes, between 60-120 minutes, and over 120 minutes, respectively. Conclusion: When the operation period is over 120 minutes, the risk of perforation increases owing to the use of greater number of tools and sutures. Perforation rate is also influenced by the duration of the operation and the experience of the surgeon. As the duration of operation is prolonged, gloves may be replaced every 90 minutes or gloves that run a higher risk of perforation due to excessive use should be changed before the suturing stage.

Özet

Amaç: Plastik cerrahi operasyonlarında eldiven delinmeleri sık olarak gözlenmekte ve bunların çoğu fark edilmeden oluşmaktadır. Bu delinmeler özellikle Hepatit B, Hepatit C ve HIV için bulaşma riski oluşturmaktadır. Gereç ve Yöntem: Bu çalışmada 66 operasyonda kullanılan 224 eldiven, kontrol amaçlı 140 eldivenle gizli perforasyon açısından karşılaştırılmıştır. Bulgular: Operasyonu yapan cerrahların perforasyon oranı %26.41 iken (uzman cerrahlarda %28.57 ve asistan cerrahlarda %24), 1. asistanlarda ise %19.49 bulunmuştur. Süresi 60 dakikadan az olan ameliyatlarda eldiven delinme oranı %13.88'dir. 60 dakika ile 120 dakika arasında süren ameliyatlarda bu oran %18.60'dır. 120 dakikadan fazla süren ameliyatlarda eldiven delinme oranı %37.87'dir. Sonuç: Operasyon süresi 120 dakikayı geçtiği zaman daha fazla alet ve dikiş kullanılması sonucu eldivenlerin delinme riski artmaktadır. Bu perforasyon oranını operasyon süresi, cerrahın deneyimi etkilemektedir. Ameliyat süresi arttıkça, örneğin 90 dakikadan sonra eldiven değişme gündeme gelebilir ya da kullanılarak hasarlanma riski artan eldivenlerin dikiş aşamasından önce değiştirilmesini önermekteyiz.

🔖

Cite This Article

KARGI, E., BABUCÇU, O., HOŞNUTER, M., TEKEREKOĞLU, B., AYOĞLU, F. N. (2004). The problem of perforation in gloves during plastic surgery operations. Medical Network Klinik Bilimler ve Doktor, Cilt: 10 - Sayı: 3, 292–295. https://ajindex.com/articles/279120

References (15)

  1. Godin MS, lavernia CJ, Harris JP. Occult surgical glove perforations in otolaryngölogy-head and neck surgery. Arch Otolaryngol Head Neck Surg 1991; 117:910-3.
  2. Hussain SA, Latif AB, Choudhary AA. Risk to surgeons: a survey of accidental injuries during operations. Br J Surg 1933. 75:314-6.
  3. Eckersley JR, Williamson DM. Glove punctures in an orthopaedic trauma unit. Injury 1990; 21:177-8.
  4. Mercan S, Güvenç H, Titiz İ. Özarmağan S, Seven R, Altuğ K. Cerrahi girişimlerde eldiven delinme problemi. Ulusal Cerrahi Dergisi 1990; 6:27-30.
  5. McNicholas TA, Jones DJ, Sibley GN. AIDS: the contamina­ tion risk in urological surgery. Br J Urol 1989; 63:565-8.
  6. Albin MS, Bunegin L, Duke ES, Ritter RR, Page CP. Anatomy of a defective barrier: sequential glove leak detection in a surgical and dental environment. Crit Care Med 1992; 20:170-84.
  7. McCue SF, Berg EW, Saunders EA. Efficacy of double- gloving as a barrier to microbial contamination during total joint arthroplasty. J Bone Joint Surg Am 1981; 63:811 -3. Serrano CW, Wright JW, Newton ER. Surgical glove perforation in obstetrics. Obstet Gynecol 1991; 77:525-8.
  8. Cole RP, Gault DT. Glove perforation during plastic surgery. BrJ Plast Surg 1989; 42:481-3.
  9. Gerberding JL, Littell G, Tarkington A, Brown A, Schecter WP. Risk of exposure of surgical personnel to patients' blood during surgery at San Francisco General Hospital. N Engl J Med 1990;322:1788-93. Hirschfield J W. Bacterial contamination of wounds from the air, from the skin of the operator and from the skin of the patient. Surg Gynecol Obstet 1941; 73:72-8. Williams N. Surgeons and the risks of contamination during operations. J R Soc Med 1991; 84:327-8.
  10. Greco RJ, Garza JR. Use of double gloves to protect the surgeon from blood contact during aesthetic procedures. Aesthetic Plast Surg 1995; 19:265-7.
  11. Marin-Bertolin S, Gonzalez-Martinez R, Gimenez CN, Marquina Vila P, Amorrortu-Velayos J. Does double gloving protect surgical staff from skin contamination during plastic surgery? Plast Reconstr Surg 1997; 99:956-60.
  12. Greco RJ, Wheatley M, McKenna P. Risk of blood contact through surgical gloves in aesthetic procedures. Aesthetic Plast Surg 1993; 17:167-8.
  13. İtil İ, Sağol S. Glove perforations during gynecologic and obstetric operations. Ege Tıp Dergisi 1997; 36:151-4.
  14. Çetinus E, Hüner H, Cever İ, Ekerbiçer H. Ortopedik cerrahide önemli bir sorun: eldiven delinmeleri. Ç.Ü. Tıp Fak Dergisi 2001; 26:96-102.
  15. Zengin N, Ateş M, Gündüz K, Okutan S. Göz cerrahisinde el­ diven delinme s