Journals / Medicine Science / 2016 / Cilt: 5 - Sayı: 0

Acoustic Radiation Force Impulse Imaging is a Useful Tool for Predicting Fibrosis Level in Patients with Chronic Hepatitis B Infection

Pages
168–170
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this letter, we want to emphasize the usefulness of acoustic radiation force impulse (ARFI) method for predicting fibrosis level which is one of the most important non-invasive techniques estimating the stiffness of the liver tissue by measuring share wave velocity.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Even though liver biopsy has been considered as the gold standard for the assessment of liver fibrosis, it has several limitations, including its invasive nature, small tissue sample size, and subjective grading system.
📊
Key Findings & Data:In recent studies, various non-invasive methods for liver fibrosis assessment have been demonstrated, including serum biomarkers and elastography techniques alternative to liver biopsy.
💡
Conclusion & Impact:In this letter, we want to emphasize the usefulness of acoustic radiation force impulse (ARFI) method for predicting fibrosis level which is one of the most important non-invasive techniques estimating the stiffness of the liver tissue by measuring share wave velocity.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Even though liver biopsy has been considered as the gold standard for the assessment of liver fibrosis, it has several limitations, including its invasive nature, small tissue sample size, and subjective grading system. In recent studies, various non-invasive methods for liver fibrosis assessment have been demonstrated, including serum biomarkers and elastography techniques alternative to liver biopsy. In this letter, we want to emphasize the usefulness of acoustic radiation force impulse (ARFI) method for predicting fibrosis level which is one of the most important non-invasive techniques estimating the stiffness of the liver tissue by measuring share wave velocity.

🔖

Cite This Article

KARAGÖZ, E., OZTURKER, C., TURHAN, V. (2016). Acoustic Radiation Force Impulse Imaging is a Useful Tool for Predicting Fibrosis Level in Patients with Chronic Hepatitis B Infection. Medicine Science, Cilt: 5 - Sayı: 0, 168–170. https://ajindex.com/articles/277744

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Frulio N, Trillaud H, Perez P, Asselineau J, Vandenhende M, Hessamfar M, Bonnet F, Maire F, Delaune J, De Ledinghen V, Morlat P. Acoustic Radiation Force Impulse (ARFI) and Transient Elastography (TE) for evaluation of liver fibrosis in HIV-HCV co-infected patients. BMC Infect Dis. 2014;14:405. Hopkirk N, Moyes CD, Lucas CR. Liver function and hepatitis markers in carriers of hepatitis B virus in New Zealand. N Z Med J. 2000;113(1107):114-6.