Journals / Medicine Science / 2018 / Cilt: 7 - Sayı: 3

Measurement uncertainty in biochemical parameters

Pages
544–547
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Clinicians should be informed about the measurement uncertainties so that they consider it while evaluating patient results.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Measurement uncertainty is a quality indicator that is used to show the distribution level of a test result in a laboratory.
📊
Key Findings & Data:The measurement uncertainty of glucose, ALT, AST, urea, creatinine, sodium, potassium, albumin, total protein and total cholesterol were investigated in the biochemical auto analyzer (Siemens Advia 2400).
💡
Conclusion & Impact:Clinicians should be informed about the measurement uncertainties so that they consider it while evaluating patient results.
🔬Design:Research Article
📍Scope:2016 Verileri
⚙️Variables:Domain Parameters

Özet

Measurement uncertainty is a quality indicator that is used to show the distribution level of a test result in a laboratory. The aim of this study is to calculate the measurement uncertainty of ten biochemical parameters investigated in our laboratory and compare the obtained values with the permissible total error values (% TEa), which various authorities determine for these tests. The measurement uncertainty of glucose, ALT, AST, urea, creatinine, sodium, potassium, albumin, total protein and total cholesterol were investigated in the biochemical auto analyzer (Siemens Advia 2400). Fifty randomly selected 2 level (low and high) internal quality assessment results and external quality assessment of six-month data, the first six months of 2016, were calculated for each test. Nordtest guide was used for the measurement uncertainty calculation. The measurement uncertainties were calculated as 3.9%, 6.72%, 3.4%, 8.06%, 9.06%, 6.08%, 5.02%, 4.98%, 4.96% and 7.22% for glucose, ALT, AST, urea, creatinine, albumin, total protein and total cholesterol, respectively. The calculated measurement uncertainties were found to be lower than the CLIA’88 and RiLi-BEAK % TEa values, except for sodium. Calculated % TEa values for creatinine, sodium, total protein and albumin were found to be higher than Fraser % TEa values. A test result or a measurement is not sufficiently effective when reliability is not assessed. Laboratories should calculate the measurement uncertainty for each parameter. They should give the results that do not exceed the targeted % TEa values. Clinicians should be informed about the measurement uncertainties so that they consider it while evaluating patient results.

🔖

Cite This Article

TELO, S., KAMAN, D. (2018). Measurement uncertainty in biochemical parameters. Medicine Science, Cilt: 7 - Sayı: 3, 544–547. https://ajindex.com/articles/277175

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Özmen GG. Klinik biyokimyada ölçüm belirsizliği. Tıpta Uzmanlık Tezi, Yeditepe Ünversitesi Tıp Fakültesi, İstanbul, 2011.
  2. Oosterhuis WP, Theodorsson E. Total error vs. measurement uncertainty: revolution or evolution? Clin Chem Lab Med. 2016;54:235-9. JCGM. Evaluation of measurement data – guide to the expression of uncertainty in measurement. JCGM 100:2008, GUM 1995 with minor corrections: Joint Committee for Guides in Metrology. 2008.
  3. Bal C, Serdar MA, Güngör OY, et al. Biyokimyasal parmetrelerinin ölçüm belirsizliğinin hesaplanması. Turk J Biochem. 2014;39:538-43. The SAC Accreditation Programme. Technical guide 4 A guide on measurement Uncertainty in medical testing, 2013;1–51.
  4. Oğul Y, Şenyurt M, Altınkaynak K, et al. TSH, FT4 ve FT3 testlerinin ölçüm belirsizliğinin değerlendirilmesi. Türk Klinik Biyokimya Derg. 2015;13:89-94.
  5. Çelebiler A, Serin H, Güleç D, et al. Klinik biyokimya laboratuvarında ölçüm belirsizliği: pratik uygulama. Türk Klinik Biyokimya Derg. 2011;36:362-6.
  6. Theodorsson E, Magnusson B, Leito I. Bias in clinical chemistry. Bioanalysis. 2014;6:2855-75. Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen. Bundesärztekammer, Berlin, Germany, 2013.
  7. Magnusson B, Näykki T, Hovind H et al. Nordtest technical report 537— handbook for the calculation of measurement uncertainty in environmental laboratories, 3nd edition, Nordic Innovation, Oslo, Norway, 2011. 1EURACHEM / CITAC Guide CG4: Quantifying Uncertainty in Analytical Measurement 2nd edition, 2000. Güngör M. Klinik Biyokimyada Ölçüm Belirsizliği. Tıpta Uzmanlık Tezi, Haseki Eğitim ve Araştırma Hastanesi, İstanbul, 2008. Ayyildiz SN. The importance of measuring the uncertainty of secondgeneration total testosterone analysis. Int J Med Biochem. 2018;1:34-9.
  8. İnce FDA, Şentürk BA, Kap S, et al. Klinik Biyokimya Laboratuvarında Glukoz Parametresi İçin Ölçüm Belirsizliği Değerlendirilmesi. Türk Klinik Biyokimya Derg. 2007;5:1-5.
  9. Ellison S, Williams A. EURACHEM/CITAC Guide CG 4: Quantifying uncertainty in analytical measurement. 2012;4–6.
  10. Aytekin M, Cevlik T, Emerk K. Describing an ideal model for calculating the uncertainty of measurements in a clinical laboratory. Clin Biochem. 2009;42:321-2.
  11. Şentür B.A, Kaplan Y.C, Yiğitbaşı T, et al. Esrar (cannabis) ve opiyat testleri için ölçme belirsizliği değerinin saptanması ve klinik karar değerine etkisi. Turk J Biochem. 2013;38:181-5.
  12. Ustundağ U, Huysal K. Measurement uncertainty of blood ethanol concentr