Journals / Journal of Turkish Spinal Surgery / 2021 / Cilt: 32 - Sayı: 2

EFFICIENCY OF SILVER-COATED TITANIUM ALLOY SCREWS IN THE PREVENTION OF IMPLANT-ASSOCIATED INFECTIONS

Pages
84–90
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Solutionfocused studies are required for developing implants with better biocompatibility, lower infection rates, and lower costs in the following years.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Instrumentation is used for treating spinal fractures.
📊
Key Findings & Data:Degenerative and neoplastic spine diseases have gradually increased in recent years because of advancements in spine surgery.
💡
Conclusion & Impact:Solutionfocused studies are required for developing implants with better biocompatibility, lower infection rates, and lower costs in the following years.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: Instrumentation is used for treating spinal fractures. Degenerative and neoplastic spine diseases have gradually increased in recent years because of advancements in spine surgery. The major disadvantage of instrumentation is implant-associated infections that result in morbidity and mortality, in addition to considerable financial losses because of increased treatment costs. This study examined the effectiveness of Ti alloy screws coated with Silver (Ag) ion nanoparticles in preventing infection in the rat spine. Materials and Methods: In this study, 24 male, six-month-old white Sprague-Dawley rats were used. The animals were divided into three groups, each with an equal number of animals. A pedicle screw of appropriate size was placed in the lumbar vertebrae of animals and inoculated with a 1 million CFU/10 microliter Staphylococcus Aureus ATCC 29213 strain. A Ti alloy microscrew with a surface area of 25 mm2 was placed in the first group, Ag-coated Ti alloy microscrew with a surface area of 25 mm2 was placed in the second group, and a Ag-coated Ti alloy microscrew with a surface area of 50 mm2 was placed in the third group. Results: Screw and tissue samples were taken and microbiologically examined. After microbiological evaluation, no statistically significant difference was reported between these groups in terms of the number of microorganisms growing on the screw and tissue. Conclusion: Because of the difficulties and financial burdens that arise after the occurrence of an infection, the importance and necessity of developing anti-infective biomaterials are very clear. No anti-infective effect was observed in the Ag-coated pedicle screws in our study. Solutionfocused studies are required for developing implants with better biocompatibility, lower infection rates, and lower costs in the following years.

🔖

Cite This Article

KAYRAN, N. A., ÜÇER, M., OFLUOĞLU, A. E. (2021). EFFICIENCY OF SILVER-COATED TITANIUM ALLOY SCREWS IN THE PREVENTION OF IMPLANT-ASSOCIATED INFECTIONS. Journal of Turkish Spinal Surgery, Cilt: 32 - Sayı: 2, 84–90. https://ajindex.com/articles/270679

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Hedequist D, Haugen A, Hresko T, Emans J. Failure of attempted implant retention in spinal deformity delayed surgical site infections. Spine. 2009;34:60-4
  2. Popat KC, Eltgroth M, Latempa TJ, Grimes CA, Desai TA. Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes. Biomaterials. 2007;28:4880-8
  3. Collins I, Wilson-MacDonald J, Chami G, Burgoyne W, Vinayakam P, Berendt T, et al. The diagnosis and management of infection following instrumented spinal fusion. Eur Spine J. 2008;17:445-50
  4. Liu D, Shen YX, Hao J. Analysis of complications associated with internal fixation for lumbar spondylolisthesis. Zhongguo Gu Shang. 2008;21:253-5
  5. Weinstein MA, McCabe JP, Cammisa FP Jr. Postoperative spinal wound infection: a review of 2,391 consecutive index procedures. J Spinal Disord. 2000;13:422-6
  6. Habash M, Reid G. Microbial biofilms: their development and significance for medical device-related infections. J Clin Pharmacol.1999;39:887-98
  7. Dunne WM Jr. Bacterial adhesion: seen any good biofilms lately? Clin Microbiol Rev. 2002;15:155-66
  8. Lucke M, Schmidmaier G, Sadoni S, Wildemann B, Schiller R, Haas NP, et al. Gentamicin coating of metallic implants reduces implantrelated osteomyelitis in rats. Bone. 2003;32:521-31
  9. Stewart PS. Mechanisms of antibiotic resistance in bacterial biofilms. Int J Med Microbiol. 2002;292:107-13
  10. Laratta JL, Shillingford JN, Hardy N, Lehman RA, Lenke LG, Riew KD. A dose-response curve for a gram-negative spinal implant infection model in rabbits. Spine (Phila Pa 1976). 2017;42:E1225-30. doi:10.1097/BRS.0000000000002205
  11. Heidenau F, Mittelmeier W, Detsch R, Haenle M, Stenzel F, Ziegler G, et al. A novel antibacterial titania coating: metal ion toxicity and in vitro surface colonization. Mater Sci Mater Med. 2005;16:883-8
  12. Picada R, Winter RB, Lonstein JE, Denis F, Pinto MR, Smith MD,et al. Postoperative deep wound infection in adults after posterior lumbosacral spine fusion with instrumentation: incidence and management. Spinal Disord. 2000;13:42-5
  13. Sapkas GS, Themistocleous GS, Mavrogenis AF, Benetos IS, Metaxas N, Papagelopoulos PJ. Stabilization of the lumbar spine using the dynamic neutralization system. Orthopedics. 2007;30:859-65
  14. Soroceanu A, Burton DC, Oren JH, Smith JS, Hostin R, Shaffrey CI, et al. Medical complications after adult spinal deformity surgery: incidence, risk factors, and clinical impact. Spine (Phila Pa 1976