Journals / El-Cezeri / 2018 / Cilt: 5 - Sayı: 3

Design of Stand-Alone PV System on a Farm House in Bilecik City, Turkey

Journal
El-Cezeri
Pages
909–916
Publication Date
2018-09-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It has been proposed to use a central inverter system for the design and it is calculated that the inverter should be at least 6 kW power.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the design of the components in the system was carried out in order to meet the energy of a stand-alone farm house in Bilecik city only by a photovoltaic (PV) system.
📊
Key Findings & Data:Firstly, the loads to be used in the farm house have been determined and it has been calculated that the average energy consumption of the house is 5.58 kWh per day.
💡
Conclusion & Impact:It has been proposed to use a central inverter system for the design and it is calculated that the inverter should be at least 6 kW power.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Stand-alone PV system · battery · inverter

Abstract

In this study, the design of the components in the system was carried out in order to meet the energy of a stand-alone farm house in Bilecik city only by a photovoltaic (PV) system. Firstly, the loads to be used in the farm house have been determined and it has been calculated that the average energy consumption of the house is 5.58 kWh per day. It was determined that it would be appropriate to use OPzS batteries in the system in order not to have power outage even if there is no solar radiation for 4 days. Under these conditions, it was estimated that 28 batteries 2 OPzS 100 model and 12 V values would be needed in the system. Since the farm house is thought to be used during the whole year, PV panels are estimated to be located at the tilt angle of 40° on the roof, which is the latitude of the city. It has been calculated that 12 PV panels with Per Light 100 Wp PLM-100P/12 model should be used for the system. It has been proposed to use a central inverter system for the design and it is calculated that the inverter should be at least 6 kW power.

Özet

In this study, the design of the components in the system was carried out in order to meet the energy of a stand-alone farm house in Bilecik city only by a photovoltaic (PV) system. Firstly, the loads to be used in the farm house have been determined and it has been calculated that the average energy consumption of the house is 5.58 kWh per day. It was determined that it would be appropriate to use OPzS batteries in the system in order not to have power outage even if there is no solar radiation for 4 days. Under these conditions, it was estimated that 28 batteries 2 OPzS 100 model and 12 V values would be needed in the system. Since the farm house is thought to be used during the whole year, PV panels are estimated to be located at the tilt angle of 40° on the roof, which is the latitude of the city. It has been calculated that 12 PV panels with Per Light 100 Wp PLM-100P/12 model should be used for the system. It has been proposed to use a central inverter system for the design and it is calculated that the inverter should be at least 6 kW power.

🔖

Cite This Article

KARAFİL, A., ÖZBAY, H. (2018). Design of Stand-Alone PV System on a Farm House in Bilecik City, Turkey. El-Cezeri, Cilt: 5 - Sayı: 3, 909–916. https://ajindex.com/articles/252531

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Chowdhury, S. A., Mourshed, M., "Off-grid electrification with solar home systems: An appraisal of the quality of components", Renewable Energy, 2016, 97: 585-598
  2. Al-Addous, M., Dalala, Z., Class, C. B., Alawneh, F., Al-Taani, H., "Performance analysis of off-grid PV systems in the Jordan valley", Renewable Energy, 2017, 113: 930-941
  3. Yahyaoui, I., Chaabene, M., Tadeo, F., "Evaluation of Maximum Power Point Tracking algorithm for off-grid photovoltaic pumping", Sustainable Cities and Society, 2016, 25: 65-73
  4. Karafil, A., Ozbay, H., Kesler, M., "Temperature and solar radiation effects on photovoltaic panel power", Journal of New Results in Science, 2016, 5(12): 48-58
  5. Ibrahim, O. E. E., "Sizing stand-alone photovoltaic systems for various locations in Sudan", Applied Energy, 1995, 52(2): 133-140
  6. Fara, L., Craciunescu, D., "Output analysis of stand-alone PV systems: modeling, simulation and control", Energy Procedia, 2017, 112: 595-605
  7. Notton, G., Muselli, M., Poggi, P., "Costing of a stand-alone photovoltaic system", Energy, 1998, 23(4): 289-308
  8. Ozbay, H., Karafil, A., Onal, Y., Kesler, M., Parmaksiz, H., "The monitoring of monthly, seasonal and yearly optimum tilt angles by raspberry pi card for Bilecik city, Turkey", Energy Procedia, 2017, 113: 311-318
  9. Li, C., Zhou, D., Yu, W., Wang, H., Zhu, D., Sun, M., Li, G., "Performance of off-grid residential solar photovoltaic power systems using five solar tracking modes in Kunming, China", International Journal of Hydrogen Energy, 2017, 42(10): 6502-6510
  10. Musa, I., Haruna, I. U., Haruna, A., "Design of an off grid photovoltaic system: A case study of government technical college, Wudil, Kano State", International Journal of Scientific & Technology Research, 2013, 2(12): 175-181
  11. Khatami, M., Mortazavi, H., Mashhadi, M. R., Oloomi, M., "Designing an off-grid PV system: For a residential consumer in Mashhad-Iran", In AFRICON, IEEE, 1-5, (2013)
  12. February, J., Mbav, W. N., Chowdhury, S., "Economic analysis of a stand-alone residential solar PV system for a typical South African middle income household", In Power Engineering Conference (UPEC), 48th International Universities'. IEEE, 4-6, (2013)
  13. Chikh, A., Chandra, A., "Sizing and power management for a stand-alone PV system in cold climate", In Transmission and Distribution Conference and Exposition (T&D), IEEE PES., 1-6, (2012)
  14. Öztürk, A., Dursun, M., "2, 10 ve 20 KVA’lık fotovoltaik sistem tasarım