Evaluation of temperature rise following the application of diode and ErCr:Ysgg lasers: an ex vivo study

Pages
131–136
Publication Date
2018-09-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion ErCr:Ysgg laser (λ=2780 nm) with 2.75 W power generates low levels of heat compared to diode lasers and may provide safer surgery in soft and bone tissues without destructive effects of temperature increase.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:DOI: 10.26650/eor.2018.479Purpose Erbium, chromium: yttrium, scandium, gallium, garnet (ErCr:Ysgg) lasers have been frequently used in oral surgical procedures and are almost seen as alternatives to diode lasers.
📊
Key Findings & Data:Materials and methods Thirty freshly dissected sheep mandibles containing bone and soft tissue were divided into 120 equal parts.
💡
Conclusion & Impact:Conclusion ErCr:Ysgg laser (λ=2780 nm) with 2.75 W power generates low levels of heat compared to diode lasers and may provide safer surgery in soft and bone tissues without destructive effects of temperature increase.
🔬Design:Modeling & Simulation
📍Scope:2018 Verileri
⚙️Variables:Bone · diode laser · ErCr:Ysgg lasers

Abstract

DOI: 10.26650/eor.2018.479Purpose Erbium, chromium: yttrium, scandium, gallium, garnet (ErCr:Ysgg) lasers have been frequently used in oral surgical procedures and are almost seen as alternatives to diode lasers. The aim of this comparative study was to analyze in an animal model the thermal elevation induced by ErCr:Ysgg and diode lasers in soft tissue and bone. Materials and methods Thirty freshly dissected sheep mandibles containing bone and soft tissue were divided into 120 equal parts. Gallium-aluminum-arsenide (Ga-Al-As) diode laser (λ=940 nm) with 1, 2 and 5 W output powers and ErCr:Ysgg laser (λ=2780 nm) with 2.75, 4.5 and 6 W output powers were used on soft and bone tissues separately for 3 seconds with point application. Mean temperature values before and after application of the lasers were compared in soft tissue and bone. Results The minimum mean temperature value was observed with 2.75 W ErCr:Ysgg laser while irradiation with 5 W diode laser created the maximum values (p<0.05). Conclusion ErCr:Ysgg laser (λ=2780 nm) with 2.75 W power generates low levels of heat compared to diode lasers and may provide safer surgery in soft and bone tissues without destructive effects of temperature increase.

🔖

Cite This Article

SİNDEL, A., DERECİ, O. N., HATİPOĞLU, M., ÖZALP, Ö., KOCABALKAN, B., ÖZTÜRK, A. (2018). Evaluation of temperature rise following the application of diode and ErCr:Ysgg lasers: an ex vivo study. European Oral Research, Cilt: 52 - Sayı: 3, 131–136. https://ajindex.com/articles/243001

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Beer F, Korpert W, Passow H, Steidler A, Meinl A, Buchmair AG, Moritz A. Reduction of collateral thermal impact of diode laser irradiation on soft tissue due to modified application parameters. Lasers Med Sci 2012; 27: 917-21
  2. Hatipoglu M, Barutcigil C. Effects of erbium-and chromium-doped yttrium scandium gallium garnet and diode lasers on the surfaces of restorative dental materials: A scanning electron microscope study. Niger J Clin Pract 2015; 18: 213-20
  3. Perussi LR, Pavone C, de Oliveira GJPL, Cerri PS, Marcantonio RAC. Effects of the er,cr:Ysgg laser on bone and soft tissue in a rat model. Lasers Med Sci 2012; 27: 95-102
  4. Romeo U, Russo C, Palaia G, Lo Giudice R, Del Vecchio A, Visca P, Migliau G, De Biase A. Biopsy of different oral soft tissues lesions by ktp and diode laser: histological evaluation. Scientific World Journal 2014; 2014: DOI:10.1155/2014/761704 5. Ryu SW, Lee SH, Yoon HJ. A comparative histological and immunohistochemical study of wound healing following incision with a scalpel, co2 laser or er,cr:Ysgg laser in the guinea pig oral mucosa. Acta Odontol Scand 2012; 70: 448-54
  5. Raymond J, Fonseca D, Robert D, Marciani D, Timothy A, Turvey D. Oral and maxillofacial surgery. Philadelphia: Saunders, 2009
  6. Merigo E, Clini F, Fornaini C, Oppici A, Paties C, Zangrandi A, Fontana M, Rocca JP, Meleti M, Manfredi M, Cella L, Vescovi P. Laser-assisted surgery with different wavelengths: A preliminary ex vivo study on thermal increase and histological evaluation. Lasers Med Sci 2013; 28: 497-504
  7. Desiate A, Cantore S, Tullo D, Profeta G, Grassi FR, Ballini A. 980 nm diode lasers in oral and facial practice: Current state of the science and art. Int J Med Sci 2009; 6: 358-64
  8. Jin JY, Lee SH, Yoon HJ. A comparative study of wound healing following incision with a scalpel, diode laser or er,cr:Ysgg laser in guinea pig oral mucosa: A histological and immunohistochemical analysis. Acta Odontol Scand 2010; 68: 232-8
  9. Cercadillo-Ibarguren I, Espana-Tost A, Arnabat-Dominguez J, Valmaseda-Castellon E, Berini-Aytes L, Gay-Escoda C. Histologic evaluation of thermal damage produced on soft tissues by co2, er,cr:Ysgg and diode lasers. Med Oral Patol Cir Bucal 2010; 15: E912-8
  10. Wang XG, Ishizaki NT, Suzuki N, Kimura Y, Matsumoto K. Morphological changes of bovine mandibular bone irradiated by er,cr: Ysgg laser: An in vitro study. J Clin Laser Med Surg 2002; 20: 245-50
  11. Deppe H, Horch HH. Laser applications in oral surgery a