Journals / European Oral Research / 2021 / Cilt: 55 - Sayı: 2

Root canal length measurement of molar teeth using cone-beam computed tomography (CBCT): comparison of two-dimensional versus three-dimensional methods

Pages
94–98
Publication Date
2021-06-28
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

If an already existing CBCT is present, it could be an alternative method for predetermination of root canal lengths in molar teeth.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose This study aimed to evaluate the validity of 2-dimensional (2D) and 3-dimensional (3D) cone-beam computed tomographic (CBCT) root canal length measurements of molar teeth compared with actual root canal lengths and the influence of canal curvature on the accuracy of CBCT measurements.
📊
Key Findings & Data:Materials and Methods Seventy root canals of 24 molar teeth were scanned using CBCT, and the root canals were categorized as; ‘straight/curved,’ ‘highly curved,’ and ‘multiple curved.’ The 2D measurements were performed within a suitable slice between the major foramen and the corresponding cusp.
💡
Conclusion & Impact:If an already existing CBCT is present, it could be an alternative method for predetermination of root canal lengths in molar teeth.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Cone-beam computed tomography · Root canal · Two-dimensional

Abstract

Purpose This study aimed to evaluate the validity of 2-dimensional (2D) and 3-dimensional (3D) cone-beam computed tomographic (CBCT) root canal length measurements of molar teeth compared with actual root canal lengths and the influence of canal curvature on the accuracy of CBCT measurements. Materials and Methods Seventy root canals of 24 molar teeth were scanned using CBCT, and the root canals were categorized as; ‘straight/curved,’ ‘highly curved,’ and ‘multiple curved.’ The 2D measurements were performed within a suitable slice between the major foramen and the corresponding cusp. The 3D measurements were performed within the slices in regular intervals of axial planes in between the same reference points. The reproducibility and reliability of the methods were analyzed by intraclass correlation coefficient. Differences between the actual and CBCT root canal lengths were evaluated by chi-square and McNemar tests if the measurements were within acceptable limits of ±0.5 mm. Results Both methods were found to be reproducible and presented excellent reliability. However, the 3D method was significantly more accurate, with an 85.7% frequency of measurements within acceptable limits (p<0.05). In ‘multiple curved’ root canals, the 3D method presented more reliable measurements than the 2D method. For ‘straight/curved’ root canals, the 2D method gave results significantly closer to the actual root canal length in comparison with ‘highly curved’ root canals (p<0.05). Conclusion The 3D measurements are more accurate than 2D measurements. If an already existing CBCT is present, it could be an alternative method for predetermination of root canal lengths in molar teeth.

🔖

Cite This Article

SİSLİ, S. N., GÜLEN, O. (2021). Root canal length measurement of molar teeth using cone-beam computed tomography (CBCT): comparison of two-dimensional versus three-dimensional methods. European Oral Research, Cilt: 55 - Sayı: 2, 94–98. https://ajindex.com/articles/242906

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. De Vos W, Casselman J, Swennen GR. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Surg 2009
  2. [CrossRef] google scholar 2. Lofthag-Hansen S, Huumonen S, Gröndahl K, Gröndahl HG. Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology. Oral Surg OralMed Oral Pathol Oral Radiol Endod 2007
  3. [CrossRef] google scholar 3. Patel S, Dawood A, Pitt Ford T, Whaites E. New dimensions in endodontic imaging: part 2. Cone beam computed tomography. Int Endod J 2009
  4. [CrossRef] google scholar 4. de Paula-Silva FW, Wu MK, Leonardo MR, da Silva LA, Wesselink PR. Accuracy of periapical radiography and cone-beam computed tomography scans in diagnosing apical periodontitis using histopathological findings as a gold standard. J Endod. 2009
  5. [CrossRef] google scholar 5. Metska ME, Aartman IH, Wesselink PR, Özok AR. Detection of vertical root fractures in vivo in endodontically treated teeth by cone-beam computed tomography scans. J Endod 2012
  6. [CrossRef] google scholar 6. Shemesh H, Cristescu R, Wesselink PR, Wu MK. The use of cone-beam computed tomography and digital periapical radiographs to diagnose root perforations. J Endod 2011
  7. [CrossRef] google scholar 7. Kamburoglu K, Kursun S, Yuksel S, Oztas B. Observer ability to detect ex vivo simulated internal or external cervical root resorption. J Endod 2011
  8. [CrossRef] google scholar 8. Ziegler CM, Woertche R, Brief J, Hassfeld S. Clinical indications for digital volume tomography in oral and maxillofacial surgery. Dentomaxillofac Radiol 2002
  9. [CrossRef] google scholar 9. Bornstein MM, Wölner-Hanssen AB, Sendi P, von Arx T. Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth. Dent Traumatol 2009
  10. [CrossRef] google scholar 10. Demirbuga S, Sekerci AE, Dincer AN, Cayabatmaz M, Zorba YO. Use of cone-beam computed tomography to evaluate root and canal morphology of mandibular first and second molars in Turkish individuals. Med Oral Patol Oral Cir Bucal 2013
  11. [CrossRef] google scholar 11. Michetti J, Maret D, Mallet JP, Diemer F. Validation of cone beam computed tomography as a tool to explore root canal anatomy. J Endod 2010
  12. [CrossRef] google scholar 12. Patel S, Durack C, Abella F, Shemesh H, Roig M, Lemberg K.