Journals / Acta Orthopaedica et Traumatologica Turcica / 2015 / Cilt: 49 - Sayı: 3

Radiation in the orthopedic operating theatre

Pages
297–301
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

During the use of fluoroscopy in orthopedic surgery, the wearing of lead aprons, neck protectors, and glasses, in addition to maintaining a distance from the tube, will reduce the radiation exposure of individuals.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of the study was to determine the amount of radiation exposure in the orthopedic operating theater, to show that the radiation dose was decreased with distance from the tube, and to inform personnel about protective measures.
📊
Key Findings & Data:Methods: Ionised radiation was measured in the orthopedic operating theater where fluoroscopy was used between 18 February 2014 and 02 June 2014.
💡
Conclusion & Impact:During the use of fluoroscopy in orthopedic surgery, the wearing of lead aprons, neck protectors, and glasses, in addition to maintaining a distance from the tube, will reduce the radiation exposure of individuals.
🔬Design:Research Article
📍Scope:2014 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of the study was to determine the amount of radiation exposure in the orthopedic operating theater, to show that the radiation dose was decreased with distance from the tube, and to inform personnel about protective measures. Methods: Ionised radiation was measured in the orthopedic operating theater where fluoroscopy was used between 18 February 2014 and 02 June 2014. Four dosimeters were placed at the head and foot of the operating table and at 200 cm from those areas at a height of 60 cm vertical to the floor. Results: At the end of 104 days, the total values were determined as 90.5 mrem at the foot of the table, 68.17 mrem at the head of the table, 7.5 mrem at 200 cm from the foot of the table, and 5.17 mrem at 200 cm from the head of the table. A significant decrease was observed in the values determined at a distance from the radiation source. Conclusion: The rate of radiation determined in the dosimeters decreased when distance from the radiation source increased. During the use of fluoroscopy in orthopedic surgery, the wearing of lead aprons, neck protectors, and glasses, in addition to maintaining a distance from the tube, will reduce the radiation exposure of individuals.

🔖

Cite This Article

ÇEÇEN, G. S., GULABİ, D., PEHLİVANOĞLU, G., BULUT, G., BEKLER, H., ASİL, K. (2015). Radiation in the orthopedic operating theatre. Acta Orthopaedica et Traumatologica Turcica, Cilt: 49 - Sayı: 3, 297–301. https://ajindex.com/articles/215440

References (15)

  1. Lee SY, Min E, Bae J, Chung CY, Lee KM, Kwon SS, et al. Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy. Spine (Phila Pa 1976) 2013;38:2108–12
  2. Kesavachandran CN, Haamann F, Nienhaus A. Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review. Eur J Med Res 2012;17:28
  3. Badman BL, Rill L, Butkovich B, Arreola M, Griend RA. Radiation exposure with use of the mini-C-arm for routine orthopaedic imaging procedures. J Bone Joint Surg Am. 2005;87:13–7
  4. Park MS, Lee KM, Lee B, Min E, Kim Y, Jeon S, et al. Comparison of operator radiation exposure between Carm and O-arm fluoroscopy for orthopaedic surgery. Radiat Prot Dosimetry 2012;148:431–8
  5. Teitelbaum GP, Shaolian S, McDougall CG, Preul MC, Crawford NR, Sonntag VK. New percutaneously inserted spinal fixation system. Spine (Phila Pa 1976) 2004;29:703–9
  6. Blakely EA. Biological effects of cosmic radiation: deterministic and stochastic. Health Phys 2000;79:495–506
  7. Arnstein PM, Richards AM, Putney R. The risk from radiation exposure during operative X-ray screening in hand surgery. J Hand Surg Br 1994;19:393–6
  8. Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 2005;13:69–76
  9. Jablon S, Bailar JC 3rd. The contribution of ionizing radiation to cancer mortality in the United States. Prev Med 1980;9:219–26
  10. Tse V, Lising J, Khadra M, Chiam Q, Nugent R, Yeaman L, et al. Radiation exposure during fluoroscopy: should we be protecting our thyroids? Aust N Z J Surg 1999;69:847–8
  11. Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Lond) 2005;55:498–500
  12. Faure E. X-rays-induced secretion of cellular factor(s) that enhance(s) HIV-1 promoter transcription in various nonirradiated transfected cell lines. Cell Mol Biol (Noisy-legrand) 1998;44:1275–92
  13. Prasarn ML, Martin E, Schreck M, Wright J, Westesson PL, Morgan T, et al. Analysis of radiation exposure to the orthopaedic trauma patient during their inpatient hospitalisation. Injury 2012;43:757–61
  14. International Commission on Radiological Protection: ICRP Publication 60: 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 1991;2:1–3
  15. Mehlman CT, DiPasquale TG. Radiation exposure to the orthopaedic surgical team during fluoroscopy: “how far away