However, due to its high residual lesion rates, it is not very effective for therapeutic excision yet

📌 3 Key Takeaways

🎯
Objective & Hypothesis:INTRODUCTION: In recent years, the number of the malpractice cases concerning the cytological misdiagnoses in the small breast lesions has gone up.
📊
Key Findings & Data:In this study, we used sonographically-guided vacuumassisted biopsy (USVAB) method to excise the lesions of 1 cm or smaller in diameter, which have unknown or low malignancy potential.
💡
Conclusion & Impact:However, due to its high residual lesion rates, it is not very effective for therapeutic excision yet
🔬Design:Research Article
📍Scope:2014 Verileri
⚙️Variables:Domain Parameters

Abstract

INTRODUCTION: In recent years, the number of the malpractice cases concerning the cytological misdiagnoses in the small breast lesions has gone up. In this study, we used sonographically-guided vacuumassisted biopsy (USVAB) method to excise the lesions of 1 cm or smaller in diameter, which have unknown or low malignancy potential. We discussed the efficiency of USVAB in diagnosing and treating such lesions. METHODS: Thirty five lesions with unknown or low malignancy potential were excised with USVAB between February-December 2014. All subjects were followed up by US for a period of 12-18 months. RESULTS: Three subjects, diagnosed by USVAB with malignancy, were referred to the surgery. All USVAB results were correlated with surgical diagnosis and longterm US follow-ups. However, 12 subjects showed residual lesions, which established a high rate (34,3%). DISCUSSION: For the small breast lesions with unknown or low malignancy potential, the USVAB method is superior with its higher diagnostic accuracy, and increases chances to diagnose breast cancer in early stages. However, due to its high residual lesion rates, it is not very effective for therapeutic excision yet

Özet

AMAÇ: Son yıllarda, memenin küçük lezyonlarında hatalı sitolojik tanılar hakkındaki malpraktis davaları artmıştır. Biz bu çalışmada, malignite potansiyeli bilinmeyen ya da düşük olan, 1 cm ve altındaki meme lezyonlarını ultrason eşliğinde vakum destekli biyopsi (USVDB) yöntemi ile eksize ettik. USVDB'nin bu lezyonların tanı ve tedavisindeki etkinliğini tartıştık. YÖNTEMLER: Şubat- Aralık 2014 tarihleri arasında, malignite potansiyeli bilinmeyen ya da düşük olan 35 lezyon USVDB ile eksize edildi. Tüm olgular, 12-18 ay boyunca US ile takibe alındı. BULGULAR: USVDB ile malignite tanısı alan üç olgu, cerrahiye yönlendirildi. USVDB'ta tüm sonuçlar cerrahi tanı ve uzun süreli US takipleri ile korele idi. Ancak 12 olguda rezidü lezyon saptanmış olup oran, yüksekti (%34,3). TARTIŞMA: Memenin malignite potansiyeli bilinmeyen ya da düşük olan küçük lezyonlarında USVDB yöntemi, yüksek tanısal doğruluk oranları ile daha üstündür ve erken evre meme kanseri tanısını arttırmaktadır. Ancak, yüksek rezidü lezyon oranları nedeniyle terapötik eksizyonda henüz başarılı değildir.

🔖

Cite This Article

SEZGİN, G., VARER, M., APAYDIN, M., DUYGULU, G. (2016). The Efficiency of The Sonographically-Guided Vacuum-Assisted Biopsy Method in Small Breast Lesionswith Unknownor Low Malignancy Potential. Kocaeli Tıp Dergisi, Cilt: 5 - Sayı: 1, 16–20. https://ajindex.com/articles/211208

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Park HL, Hong J. Vacuum-assisted breast biopsy for breast cancer. Gland Surg 2014; 3:120-7.
  2. Strachan C, Horgan K, Millican-Slater RA, et al. Outcome of a new patient pathway for managing B3 breast lesions by vacuum-assisted biopsy: time to change current UK practice? 2016; 69:248-54.
  3. Rajan S, Shaaban AM, Dall BJ, et al. New patient pathway using vacuum-assisted biopsy reduces diagnostic surgery for B3 lesions. Clin Radiol 2012; 67:244-9.
  4. Lee S, Jung Y, Bae Y. Synchronous BI-RADS Category Ultrasonography in Patients with Breast Cancer: Is Short-Term Follow-Up Appropriate? J Breast Cancer 2015; 18:181-6. Preoperative 5. Grimm LJ, Anderson AL, Baker JA, et al. Frequency Characteristics of Probably Benign Lesions Seen at Breast MRI. Am J Roentgenol 2015; 205:442-7.
  5. Pieri A, Hemming D, Westgarth J, et al. Vacuum-assisted biopsy is a viable alternative to surgical biopsy in the investigation of breast lesions of uncertain malignant potential. Surgeon 2015 Oct; [Epub ahead of print]. Sedgwick EL, Ebuoma L, Hamame A, et al. BI- RADS update for breast cancer caregivers. Breast Cancer Res Treat 2015; 150:243-54.
  6. Kibil W, Hodorowicz-Zaniewska D, Szczepanik A, et al. Ultrasound-guided vacuum-assisted core biopsy in the diagnosis and treatment of focal lesions of the breast - own experience. Wideochir Inne Tech Malo Inwazyjne 2013; 8:63-8.
  7. Nakano S, Otsuka M, Mibu A, et al. Significance of fine needle aspiration cytology and vacuum-assisted core needle biopsy for small breast lesions. Clin Breast Cancer 2015; 15:23-6.
  8. Povoski SP, Jimenez RE, Wang WP. Ultrasound-guided methodology: retrospective comparison of the 8- gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach. World J Surg Oncol 2011; 9: 87-101. biopsy 11. Parker SH, Klaus AJ, McWey PJ, et al. Sonographically assisted breast biopsy using a handheld device. Am J Roentgenol 2001; 177:405-8. vacuum- 12. Lai JT, Burrowes P, MacGregor JH. Vacuum- assisted large-core breast biopsy: complications and their incidence. Can Assoc Radiol J 2000; 51: 232-36.
  9. Pan S, Liu W, Jin K, et al. Ultrasound-guided vacuum-assisted breast biopsy using Mammotome biopsy system for detection of breast cancer: results from two high volume hospitals. Int J Clin Exp Med 2014; 7:239-46.
  10. Cassano E, Urban LA, Pizzamiglio M, et al. Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases. Breast Cancer Res Treat 2007; 102:103-10.
  11. Sebag P, Tourasse C, Rouyer N, et al. Value of vacuum