Journals / Diagnostic and Interventional Radiology / 2015 / Cilt: 21 - Sayı: 4

Iliorenal periscope graft to maintain blood flow to accessory renal artery

Pages
334–337
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this case, left accessory renal artery flows were provided by an iliorenal periscope graft that extends from the left accessory renal artery to the right common iliac artery in a retrograde fashion.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Parallel endografts such as "chimney" and "periscope" are being increasingly used to maintain blood flow to visceral and supra-aortic branches in patients with different aortic disorders.
📊
Key Findings & Data:We present a new technique, "iliorenal periscope graft", in a patient with abdominal aortic aneurysm undergoing endovascular aortic repair.
💡
Conclusion & Impact:In this case, left accessory renal artery flows were provided by an iliorenal periscope graft that extends from the left accessory renal artery to the right common iliac artery in a retrograde fashion.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Parallel endografts such as "chimney" and "periscope" are being increasingly used to maintain blood flow to visceral and supra-aortic branches in patients with different aortic disorders. We present a new technique, "iliorenal periscope graft", in a patient with abdominal aortic aneurysm undergoing endovascular aortic repair. In this case, left accessory renal artery flows were provided by an iliorenal periscope graft that extends from the left accessory renal artery to the right common iliac artery in a retrograde fashion.

🔖

Cite This Article

CANYİĞİT, M., HIDIROĞLU, M., UĞUZ, E., ÇETİN, H. (2015). Iliorenal periscope graft to maintain blood flow to accessory renal artery. Diagnostic and Interventional Radiology, Cilt: 21 - Sayı: 4, 334–337. https://ajindex.com/articles/210801

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Banno H, Cochennec F, Marzelle J, Becquemin JP. Comparison of fenestrated endovascular aneurysm repair and chimney graft techniques for parare- nal aortic aneurysm. J Vasc Surg 2014; 60:31-39. [CrossRef] Bosiers MJ, Bisdas T, Donas KP, Torsello G, Aus- termann M. Early experience with the first com- mercially available off-the-shelf multibranched endograft (t-branch) in the treatment of thora- coabdominal aortic aneurysms. J Endovasc Ther 2013; 20:719-725. [CrossRef] Moulakakis KG, Mylonas SN, Dalainas I, et al. The chimney-graft technique for preserving su- pra-aortic branches: a review. Ann Cardiothorac Surg 2013; 2:339-346. o July-August 2015 o Diagnostic and Interventional Radiology Canyigit et al. Greenberg JI, Dorsey C, Dalman RL, et al. Long- term results after accessory renal artery cover- age during endovascular aortic aneurysm repair. J Vasc Surg 2012; 56:291-296. [CrossRef] Aquino RV, Rhee RY, Muluk SC, Tzeng EY, Carrol NM, Makaroun MS. Exclusion of accessory renal arteries during endovascular repair of abdominal aortic aneurysms. J Vasc Surg 2001; 34:878-884. [CrossRef] Pecoraro F, Pfammatter T, Mayer D, et al. Mul- tiple periscope and chimney grafts to treat rup- tured thoracoabdominal and pararenal aortic aneurysms. J Endovasc Ther 2011; 18:642-649. [CrossRef] Wu IH, Chan CY, Chen YS, Huang SC, Wang SS, Chi NH. Crossover chimney technique to pre- serve the internal iliac artery in abdominal aortic aneurysm with common iliac artery aneurysms. J Endovasc Ther 2013; 20:298-302. [CrossRef]