Journals / Acta Orthopaedica et Traumatologica Turcica / 2016 / Cilt: 50 - Sayı: 6

Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates

Pages
665–669
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Level of Evidence: Level IV, Therapeutic study

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Anatomic volar rim locking plates are designed with the aim of treating intraarticular distal radius fractures.
📊
Key Findings & Data:In this study, we sought to determine the radiological and functional results and rate of complications of these plates.
💡
Conclusion & Impact:Level of Evidence: Level IV, Therapeutic study
🔬Design:Review & Systematic Survey
📍Scope:2011 Verileri
⚙️Variables:Domain Parameters

Abstract

Objective: Anatomic volar rim locking plates are designed with the aim of treating intraarticular distal radius fractures. When used to treat comminuted distal radius fractures, these plates can damage the flexor tendons. In this study, we sought to determine the radiological and functional results and rate of complications of these plates. Methods: We retrospectively reviewed the records of 36 patients (28 males, 8 females; mean age: 46.4 years) with AO/OTA Type C2-C3 distal radius fractures treated with anatomic volar rim distal radius plates between January 2011 and December 2014. Radial length, radial inclination and palmar tilt were compared with the intact wrist. Results were evaluated with the Mayo wrist and Lidstrom scores. Complications were documented throughout the follow-up period of 23.8 (range: 12 to 48) months. Results: Postoperative measurements of the radial length, inclination and palmar tilt did not differ significantly. Mayo wrist and Lidstrom scores were good and excellent in 27 and 32 patients, respectively. Flexor tenosynovitis was symptomatic in 15 patients and asymptomatic (localized swelling only) in 21. Plates were removed from 15 patients due to symptomatic tenosynovitis and from six patients due to partial rupture of the flexor pollicis longus tendon. The flexor digitorum profundus tendon of the second finger was also partially ruptured in three patients. Conclusion: Anatomic volar rim locking plates provide satisfying radiological and functional results in treating AO/OTA Type C2-C3 comminuted distal radius fractures. However, if these plates interfere with the union of the fracture, they should be removed to avoid potential tendon problems caused by their placement in the rim region. Level of Evidence: Level IV, Therapeutic study

🔖

Cite This Article

KARA, A., ÇELİK, H., ÖÇ, Y., UZUN, M., ERDİL, M., TETİK, C. (2016). Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates. Acta Orthopaedica et Traumatologica Turcica, Cilt: 50 - Sayı: 6, 665–669. https://ajindex.com/articles/201662

References (13)

  1. Cooney 3rd WP, Linscheid RL, Dobyns JH. External pin fixation for unstable Colles' fractures. J Bone Jt Surg Am. 1979;61:840e845
  2. Chin KR, Jupiter JB. Wire-loop fixation of volar displaced osteochondral fractures of the distal radius. J Hand Surg Am. 1999;24:525e533
  3. Bakker AJ, Shin AY. Fragment-specific volar hook plate for volar marginal rim fractures. Tech Hand Up Extrem Surg. 2014;18:56e60
  4. Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14:227e234
  5. Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27:1e6
  6. Casaletto JA, Machin D, Leung R, Brown DJ. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur Vol. 2009;34:471e474
  7. Jupiter JB, Marent-Huber M, Group LCPS. Operative management of distal radial fractures with 2.4-millimeter locking plates: a multicenter prospective case series. Surg Tech J Bone Jt Surg Am. 2010;92(Suppl 1 Pt 1):96e106
  8. Suganuma S, Tada K, Tsuchiya H. Reducing the risk of flexor pollicis longus tendon rupture after volar plate fixation for distal radius fractures: validation of the tendon irritation test. Eur J Orthop Surg Traumatol. 2014;24: 1425e1429
  9. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316e322
  10. Konstantinidis L, Helwig P, Strohm PC, Hirschmuller A, Kron P, Sudkamp NP. Clinical and radiological outcomes after stabilisation of complex intra-articular fractures of the distal radius with the volar 2.4 mm LCP. Arch Orthop Trauma Surg. 2010;130:751e757
  11. Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium e 2007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma. 2007;21:S1eS133
  12. Osada D, Kamei S, Masuzaki K, Takai M, Kameda M, Tamai K. Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg Am. 2008;33:691e700. 13. http://synthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America/ Product Support Materials/Technique Guides/SUTG2.4VALCPVolar RimDRPJ10270C.pdf
  13. Amadio PC, Berquist TH, Smith DK, Ilstrup DM, Cooney 3rd WP, Linscheid RL. Scaphoid malunion.