This study aims to emphesize the risk of atypic dislocation in case of incongruency of head and femoral stem of hemiarthroplasty

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Dislocation of hemiarthroplasty after hip fracture surgery is a rare complication and mostly occurs as a total luxation of head from acetabulum.
📊
Key Findings & Data:In our case, dislocation occured between head of prosthesis and femoral stem after operation with Leinbach type hemiarthroplasty due to intertrochanteric femur fracture .
💡
Conclusion & Impact:This study aims to emphesize the risk of atypic dislocation in case of incongruency of head and femoral stem of hemiarthroplasty
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Dislocation of hemiarthroplasty after hip fracture surgery is a rare complication and mostly occurs as a total luxation of head from acetabulum. In our case, dislocation occured between head of prosthesis and femoral stem after operation with Leinbach type hemiarthroplasty due to intertrochanteric femur fracture . Although head of prosthesis stayed in acetabulum, femoral stem luxated posterosuperiorly. This study aims to emphesize the risk of atypic dislocation in case of incongruency of head and femoral stem of hemiarthroplasty

Özet

Kalça kırığı sonrası uygulanan parsiyel protezlere bağlı çıkıklar, karşılaşılabilecek komplikasyonlar arasındadır. Bu çıkıklar femoral başın bir bütün şeklinde doğal asetabulumdan ayrılması şeklinde görülür. Bizim olgumuzda ise intertrokanterik femur kırığı nedeniyle 2002 yılında kalkar destekli Leinbach tipi parsiyel protez uygulaması sonrası femoral baş ile stem arasında çıkık meydana gelmiş- tir. Parsiyel protezin baş kısmı asetabulumda kalmış, femoral stem ise posterosuperior yönde çıkmış- tır. Bu yazıda baş boyun replasmanlı parsiyel protezlerde baş ve boyun uyumsuzluğu olduğunda atipik protez çıkıkları gelişebileceği vurgulanmak istenmiştir.

🔖

Cite This Article

KARA, A., ÖÇ, Y., ŞEKER, A., UZUN, M., ERTÜRER, E., ÖZTÜRK, İ. (2013). A rare type of dislocation of hemiarthroplasty after intertrochanteric fracture. Şişli Etfal Hastanesi Tıp Bülteni, Cilt: 47 - Sayı: 3, 154–156. https://ajindex.com/articles/363447

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. Uzun M, Ertürer E, Oztürk I, Akman S, Seçkin F, Ozçelik IB. Long-term radiographic complications following treatment of unstable intertrochanteric femoral fractures with the proximal femoral nail and effects on functional results. Acta Orthop Traumatol Turc 2009;43(6):457-63
  2. Oztürk I, Toker S, Ertürer E, Aksoy B, Seçkin F. Analysis of risk factors affecting mortality in elderly patients (aged over 65 years) operated on for hip fractures. Acta Orthop Traumatol Turc 2008;42(1):16-21
  3. Pajarinen J, Lindahl J, Michelsson O, Savolainen V, Hirvensalo E. Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation. J Bone Joint Surg Br 2005;87:76-81
  4. Sancheti Kh, Sancheti P, Shyam A, Patil S, Dhariwal Q, Joshi R. Primary hemiarthroplasty for unstable osteoporotic intertrochanteric fractures in the elderly: A retrospective case series. Indian J Orthop 2010;44(4):428-34
  5. Madanat R, Makinen TJ, Ovaska MT, Soiva M, Vahlberg T, Haapala J. Dislocation of hip hemiarthroplasty following posterolateral surgical approach: a nested case-control study. Int Orthop 2012;36(5):935-40
  6. A Kıral, M Kuskucu, H Kaplan, K Çuhadar, A Sarıdoğan, A Yaşar. Primary hemiarthroplasty with Leinbach prosthesis in the treatment of unstable intertrochanteric and subtrochanteric hip fractures. Acta Orthop Traumatol Turc 1993;27(3):187-91
  7. Barmada R, Mess D. Bateman hemiarthroplasty component disassembly. A report of three cases of high-density polyethylene failure. Clin Orthop Relat Res 1987;224:147-9
  8. Incavo SJ, Ninomiya J, Howe JG, Mayor MB. Failure of the polyethylene liner leading to notching of the femoral component in bipolar prostheses. Orthop Rev 1993;22(6):728-32.