Journals / Turkish Journal of Electrical Engineering and Computer Science / 2016 / Cilt: 24 - Sayı: 3

Grid-connected induction generator interturn fault analysis using a PCA-ANN-based algorithm

Pages
1340–1350
Publication Date
2016-06-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It has a structure that may be used in different systems or kinds of failure with data receiving and software changes.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:It is difficult for short circuits among the internal windings of one phase in electrical machines to be determined in a reliable and speedy manner.
📊
Key Findings & Data:We tested the real-time faults and measured the system performance with the installed test rig.
💡
Conclusion & Impact:It has a structure that may be used in different systems or kinds of failure with data receiving and software changes.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:PCA · induction generator · faults

Abstract

It is difficult for short circuits among the internal windings of one phase in electrical machines to be determined in a reliable and speedy manner. The failure currents that occur, especially in short circuits with a few windings, are at such low levels that they cannot be determined by relay systems. This results in growing faults and damage. In this study, we designed a model that can define winding failures successfully at very small levels by using the PCA and ANN algorithms. We tested the real-time faults and measured the system performance with the installed test rig. The developed protection model determined fault determination in very small (2.5%) winding failures with acceptable accuracy. The suggested model is a counter-speed, selective, flexible, and economical protection model that may be used for internal failures of electrical machines. It has a structure that may be used in different systems or kinds of failure with data receiving and software changes.

🔖

Cite This Article

BAYAR, H., TERZİ, Ü. K. (2016). Grid-connected induction generator interturn fault analysis using a PCA-ANN-based algorithm. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 24 - Sayı: 3, 1340–1350. https://ajindex.com/articles/187821

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...