Journals / Turkish Journal of Electrical Engineering and Computer Science / 2019 / Cilt: 27 - Sayı: 2

Automated elimination of EOG artifacts in sleep EEG using regression method

Pages
1094–1108
Publication Date
2019-04-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed that elimination of EOG artifacts raised the classification accuracy on each subject at a range of 1 % - 1.5 %.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Sleep electroencephalogram (EEG) signal is an important clinical tool for automatic sleep staging process.
📊
Key Findings & Data:A dataset consisting of 58 h and 6941 epochs was used in the research.
💡
Conclusion & Impact:The results showed that elimination of EOG artifacts raised the classification accuracy on each subject at a range of 1 % - 1.5 %.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Artificial neural networks · electrooculogram artifact elimination · regression

Abstract

Sleep electroencephalogram (EEG) signal is an important clinical tool for automatic sleep staging process. Sleep EEG signal is effected by artifacts and other biological signal sources, such as electrooculogram (EOG) and electromyogram (EMG), and since it is effected, its clinical utility reduces. Therefore, eliminating EOG artifacts from sleep EEG signal is a major challenge for automatic sleep staging. We have studied the effects of EOG signals on sleep EEG and tried to remove them from the EEG signals by using regression method. The EEG and EOG recordings of seven subjects were obtained from the Sleep Research Laboratory of Meram Medicine Faculty of Necmettin Erbakan University. A dataset consisting of 58 h and 6941 epochs was used in the research. Then, in order to see the consequences of this process, we classified pure sleep EEG and artifact-eliminated EEG signals with artificial neural networks (ANN). The results showed that elimination of EOG artifacts raised the classification accuracy on each subject at a range of 1 % - 1.5 %. However, this increase was obtained for a single parameter. This can be regarded as an important improvement if the whole system is considered. However, different artifact elimination strategies combined with different classification methods for another sleep EEG artifact may give higher accuracy differences between original and purified signals.

🔖

Cite This Article

DURSUN, M., ÖZŞEN, S., GÜNEŞ, S., AKDEMİR, B., YOSUNKAYA, Ş. (2019). Automated elimination of EOG artifacts in sleep EEG using regression method. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 27 - Sayı: 2, 1094–1108. https://ajindex.com/articles/186782

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...