Journals / Acta Orthopaedica et Traumatologica Turcica / 2017 / Cilt: 51 - Sayı: 3

Elastoplasty as a promising novel technique: Vertebral augmentation with an elastic silicone-based polymer

Pages
209–214
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Therefore, elastoplasty may be a good viable option in the treatment of VCFs asit cause less complications and can prevent adjacent level fractures.Level of evidence: Level IV, therapeutic study.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) restores the stiffness andthe strength of fractured vertebral bodies, but changes the pattern of the stress transfer.
📊
Key Findings & Data:The aim of this study is to retrospectively evaluate the clinical results of theelastoplasty procedure.Materials and methods: Thirthy nine patients (9 males, 30 females, 87 spinal levels) were clinicallyevaluated pre and postoperatively in terms of pain relief, leakage and silicone embolism.
💡
Conclusion & Impact:Therefore, elastoplasty may be a good viable option in the treatment of VCFs asit cause less complications and can prevent adjacent level fractures.Level of evidence: Level IV, therapeutic study.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) restores the stiffness andthe strength of fractured vertebral bodies, but changes the pattern of the stress transfer. This effect maycause a secondary fracture of the adjacent vertebrae. Elastoplasty has emerged as a new technique toovercome this complication. The aim of this study is to retrospectively evaluate the clinical results of theelastoplasty procedure.Materials and methods: Thirthy nine patients (9 males, 30 females, 87 spinal levels) were clinicallyevaluated pre and postoperatively in terms of pain relief, leakage and silicone embolism. The mean agewas 67 (range 38e84) years. The mean follow up period was 12,5 months. The patients were evaluatedradiologically for the presence of adjacent level fractures postoperatively. Complications were recorded.Results: The mean VAS score decreased from 7,5 to 3,5 during the last follow-up. Symptomatic siliconepulmonary embolism was not encountered in any patients. Leakage was observed in 5 (13%) cases. Therewas an adjacent level fracture in 1 case and another fracture which was not at the adjacent level inanother one. A hematoma occurred in the needle entry site in a patient with trombocytopenia (<70,000).Conclusions: Elastoplasty is a safe, promising technique in the treatment of vertebral compressionfractures (VCFs). Symptomatic silicone pulmonary embolism is not observed. The material's stiffness isclose to intact vertebrae. Therefore, elastoplasty may be a good viable option in the treatment of VCFs asit cause less complications and can prevent adjacent level fractures.Level of evidence: Level IV, therapeutic study.

🔖

Cite This Article

GASBARRINI, A., GHERMANDI, R., AKMAN, Y. E., GİROLAMİ, M., BORIANI, S. (2017). Elastoplasty as a promising novel technique: Vertebral augmentation with an elastic silicone-based polymer. Acta Orthopaedica et Traumatologica Turcica, Cilt: 51 - Sayı: 3, 209–214. https://ajindex.com/articles/186463

References (14)

  1. Galibert P, Deramond H, Rosat P, Le Gars D. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie. 1987;33(2):166e168
  2. Heo DH, Chin DK, Yoon YS, Kuh SU. Recollapse of previous vertebral compression fracture after percutaneous vertebroplasty. Osteoporos Int. 2009;20(3):473e480
  3. Yoshii T, Ueki H, Kato T, Tomizawa S, Okawa A. Severe kyphotic deformity resulting from collapses of cemented and adjacent vertebrae following percutaneous vertebroplasty using calcium phosphate cement. A case report. Skelet Radiol. 2014;43(10):1477e1480
  4. Lin WC, Lee YC, Lee CH, et al. Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysis. Eur Spine J. 2008;17(4): 592e599
  5. Harrop JS, Prpa B, Reinhardt MK, Lieberman I. Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty. Spine (Phila Pa 1976). 2004;29(19):2120e2125
  6. Han SL, Wan SL, Li QT, et al. Is vertebroplasty a risk factor for subsequent vertebral fracture, meta-analysis of published evidence? Osteoporos Int. 2015;26(1):113e122
  7. Trout AT, Kallmes DF. Does vertebroplasty cause incident vertebral fractures? A review of available data. AJNR Am J Neuroradiol. 2006;27(7):1397e1403
  8. Fahim DK, Sun K, Tawackoli W, et al. Premature adjacent vertebral fracture after vertebroplasty: a biomechanical study. Neurosurgery. 2011;69(3): 733e744
  9. Baroud G, Nemes J, Heini P, Steffen T. Load shift of the intervertebral disc after a vertebroplasty: a finite-element study. Eur Spine J. 2003;12(4):421e426
  10. Nagaraja S, Awada HK, Dreher ML. Vertebroplasty increases trabecular microfractures in elderly female cadaver spines. Osteoporos Int. 2015;26(7): 2029e2034
  11. Polikeit A, Nolte LP, Ferguson SJ. The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis. Spine (Phila Pa 1976). 2003;28(10):991e996
  12. Kim JM, Shin DA, Byun DH, Kim HS, Kim S, Kim HI. Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplasty. J Korean Neurosurg Soc. 2012;52(5):435e440
  13. Schulte TL, Keiler A, Riechelmann F, Lange T, Schmoelz W. Biomechanical comparison of vertebral augmentation with silicone and PMMA cement and two filling grades. Eur Spine J. 2013;22(12):2695e2701
  14. Bornemann R, Rommelspacher Y, Jansen TR, Sander K, Wirtz DC, Pflugmacher R. Elastoplasty: a silicon pol