Journals / Turkish Journal of Chemistry / 2018 / Cilt: 42 - Sayı: 6

Determination of hydrogen peroxide with an enzymeless amperometric sensor based on poly(vinylferrocene)-supported Ag nanoparticles

Pages
1755–1767
Publication Date
2018-12-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Finally, interference effects of uric acid, ascorbic acid, dopamine, and glucose molecules were studied and no significant interference was observed at physiological levels.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:An enzymeless electrochemical sensor for detection of low amounts of H$_{2}$O$_{2}$ with the aid of Ag nanoparticles supported on conducting poly(vinylferrocene) (PVF) film was developed.
📊
Key Findings & Data:The results revealed that the sensor developed was easy-to-prepare, economic, selective, and sensitive, with a fast response time of 3 s.
💡
Conclusion & Impact:Finally, interference effects of uric acid, ascorbic acid, dopamine, and glucose molecules were studied and no significant interference was observed at physiological levels.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Hydrogen peroxide determination · electrochemical sensor · poly(vinylferrocene)

Abstract

An enzymeless electrochemical sensor for detection of low amounts of H$_{2}$O$_{2}$ with the aid of Ag nanoparticles supported on conducting poly(vinylferrocene) (PVF) film was developed. Experimental results revealed that contribution of Ag nanoparticles led to remarkable improvement by means of reduction potential and reduction current. Influence of experimental parameters (i.e. polymeric film thickness, concentration of Ag precursor, immersion time in precursor solution, reduction time, and reduction potential) were investigated. The Ag/PVF-modified electrode system was characterized physically by scanning electron microscopy. The results revealed that the sensor developed was easy-to-prepare, economic, selective, and sensitive, with a fast response time of 3 s. The linear concentration range of the sensor was 0.1-50 mM, with a sensitivity of 14.1 $\mu $A mM$^{-1}$ and a limit of detection of 0.94 $\mu $M. Finally, interference effects of uric acid, ascorbic acid, dopamine, and glucose molecules were studied and no significant interference was observed at physiological levels.

🔖