Journals / Turkish Journal of Chemistry / 2020 / Cilt: 44 - Sayı: 2

Development of a biosensor platform based on ITO sheets modified with 3-glycidoxypropyltrimethoxysilane for early detection of TRAP1

Pages
461–471
Publication Date
2020-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The electrochemical immunosensor has presented an extremely wide determination range for TRAP1 from 0.1 pg/mL to 100 pg/mL.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of this research was to design an electrochemical immunosensor for determination of tumour necrosis factor receptor-associated protein-1 TRAP1 antigen, a heat shock protein linked to tumour necrosis factor.
📊
Key Findings & Data:The indium-tin oxide covered polyethylene terephthalate ITO-PET electrode surface was cleaned and was prepared for the introduction of hydroxyl groups on its surface by using NH$_{4}$ OH/H$_{2}$O$_{2}$/H$_{2}$O.
💡
Conclusion & Impact:The electrochemical immunosensor has presented an extremely wide determination range for TRAP1 from 0.1 pg/mL to 100 pg/mL.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:3-GOPS · ITO-PET · TRAP1

Abstract

The aim of this research was to design an electrochemical immunosensor for determination of tumour necrosis factor receptor-associated protein-1 TRAP1 antigen, a heat shock protein linked to tumour necrosis factor. The indium-tin oxide covered polyethylene terephthalate ITO-PET electrode surface was cleaned and was prepared for the introduction of hydroxyl groups on its surface by using NH$_{4}$ OH/H$_{2}$O$_{2}$/H$_{2}$O. As a silanization agent for covalent attachment of anti-TRAP1 on the surface of the ITO working electrode, 3-glycidoxypropyltrimethoxysilane 3-GOPS was used. Cyclic voltammetry CV and electrochemical impedance spectroscopy EIS were used to characterize the immobilization steps. A variety of parameters, 3-GOPS and anti-TRAP1 concentrations, and anti-TRAP1 and TRAP1 incubation durations were optimized. After determining the optimum conditions, characterization studies such asrepeatability,reproducibility,regeneration,squarewavevoltammetry,andsinglefrequencyimpedancewereperformed. The electrochemical immunosensor has presented an extremely wide determination range for TRAP1 from 0.1 pg/mL to 100 pg/mL.

🔖

Cite This Article

VURAL, B., ÇALIŞKAN, M., SEZGİNTÜRK, M. K. (2020). Development of a biosensor platform based on ITO sheets modified with 3-glycidoxypropyltrimethoxysilane for early detection of TRAP1. Turkish Journal of Chemistry, Cilt: 44 - Sayı: 2, 461–471. https://ajindex.com/articles/184211

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Lin MH, Shen KY, Liu BS, Chen IH, Sher YP. Immunological evaluation of a novel HLA-A2 restricted phosphopeptide of tumor associated Antigen, TRAP1, on cancer therapy. Vaccine 2019
  2. X (1): 100017. doi: 10.1016/j.jvacx.2019.100017 2. Li S, Sun X, Xu J, Gu Y, Liu S. Association study of TRAP1 gene polymorphisms with susceptibility and glucocorticoid efficacy of systemic lupus erythematosus. Gene 2018
  3. doi: 10.1016/j.gene.2018.05.109 3. Lin MH, Shen KY, Liu BS, Chen IH, Sher YP. Immunological evaluation of a novel HLA-A2 restricted phosphopeptide of tumor associated Antigen, TRAP1, on cancer therapy. Vaccine 2019
  4. X (1): 100017. doi: 10.1016/j.jvacx.2019.100017 4. Rondanin R, Lettini G, Oliva P, Baruchello R, Costantini C et al. New TRAP1 and Hsp90 chaperone inhibitors with cationic components: preliminary studies on mitochondrial targeting. Bioorganic & Medicinal Chemistry Letters 2018
  5. 28 (13): 2289-2293. doi: 10.1016/j.bmcl.2018.05.031 5. Wu H, Liao J, Li Q, Yang M, Zhao M. Epigenetics as biomarkers in autoimmune diseases. Clinical Immunology 2018
  6. doi: 10.1016/j.clim.2018.03.011 6. Aydın EB, Sezgintürk MK. Indium tin oxide (ITO): a promising material in biosensing technology. TrAC Trends in Analytical Chemistry 2017
  7. doi: 10.1016/j.trac.2017.09.021 7. Aydın EB, Sezgintürk MK. A comparison between LP (GMA) and CLP (GMA) polymer composites as an immobilization matrix for biosensing applications: A model immunosensor for IL 1α. Analytica Chimica Acta 2019. doi: 10.1016/j.aca.2019.05.049 8. Aydın M, Aydın EB, Sezgintürk MK. Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly (phosphazene) modified disposable ITO electrode: a new fabrication strategy for biosensors. Biosensors and Bioelectronics 2019
  8. doi: 10.1016/j.bios.2018.10.051 9. Karaboğa MNS, Sezgintürk MK. Cerebrospinal fluid levels of alpha-synuclein measured using a poly-glutamic acidmodified gold nanoparticle-doped disposable neuro-biosensor system. Analyst 2019
  9. 144 (2): 611-621. doi: 10.1039 / C8AN01279B 10. Lee JH, Nguyen H B-C, Ko E, Kim JH, Seong GH. Fabrication of flexible, transparent silver nanowire electrodes for amperometric detection of hydrogen peroxide. Sensors Actuators B: Chemical 2016
  10. doi: 10.1016/j.snb.2015.11.006 11. Li HH, Wang HH, Li WT, Fang XX, Guo XC et al. A novel electrochemical sensor for epinephrine based on three dimensional molecularly imprinted polymer arrays. Senso