Journals / Turkish Journal of Veterinary and Animal Sciences / 2004 / Cilt: 28 - Sayı: 2

Effect of Ultrasound Treatment on Milk Homogenisation and Particle Size Distribution of Fat

Pages
303–308
Publication Date
2004-02-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It was found that ultrasound treatment with high amplitude (power) had an important effect on milk homogenisation compared with conventional homogenisation.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The effect of ultrasound treatment on milk homogenisation was studied.
📊
Key Findings & Data:As exposure times and power levels increased, homogenisation efficiency also rose.
💡
Conclusion & Impact:It was found that ultrasound treatment with high amplitude (power) had an important effect on milk homogenisation compared with conventional homogenisation.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Ultrasound · homogenisation · fat globule

Abstract

The effect of ultrasound treatment on milk homogenisation was studied. A microscope, equipped with a camera and ocular micrometer, was used to determine the diameters of fat globules and to evaluate the homogenisation efficiency of milk samples homogenised by using ultrasonic and conventional homogeniser. It was found that ultrasound treatment with high amplitude (power) had an important effect on milk homogenisation compared with conventional homogenisation. As exposure times and power levels increased, homogenisation efficiency also rose. The highest homogenisation efficiency and the smallest fat globule diameter were 3.22 and 0.725 µm at power level 100 (450 W) for 10 min, respectively. The fat globule diameters at a power level of 40 (180 W) for 10 min were similar to those of conventional homogenisation.

Özet

The effect of ultrasound treatment on milk homogenisation was studied. A microscope, equipped with a camera and ocular micrometer, was used to determine the diameters of fat globules and to evaluate the homogenisation efficiency of milk samples homogenised by using ultrasonic and conventional homogeniser. It was found that ultrasound treatment with high amplitude (power) had an important effect on milk homogenisation compared with conventional homogenisation. As exposure times and power levels increased, homogenisation efficiency also rose. The highest homogenisation efficiency and the smallest fat globule diameter were 3.22 and 0.725 µm at power level 100 (450 W) for 10 min, respectively. The fat globule diameters at a power level of 40 (180 W) for 10 min were similar to those of conventional homogenisation.

🔖

Cite This Article

ERTUGAY, M. F., ŞENGÜL, M., ŞENGÜL, M. (2004). Effect of Ultrasound Treatment on Milk Homogenisation and Particle Size Distribution of Fat. Turkish Journal of Veterinary and Animal Sciences, Cilt: 28 - Sayı: 2, 303–308. https://ajindex.com/articles/175268

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...