Journals / NanoEra / 2026 / Volume: 6 Issue: 1

Voltammetric Determination of Dopamine in Pharmaceutical Preparations Using a Platinum Electrode

Bilal Yılmaz(ATATÜRK ÜNİVERSİTESİ, ECZACILIK FAKÜLTESİ)0000-0002-8574-7570
Journal
NanoEra
Pages
—
Publication Date
2026-07-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Overall, the proposed methods are accurate, precise, and practical for the determination of dopamine in Dopadren solution and may also be applied to other pharmaceutical formulations.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of this study was to develop and validate simple, fast, and reliable electrochemical techniques including cyclic voltammetry, linear sweep voltammetry, square wave voltammetry, and differential pulse voltammetry for the determination of dopamine in pharmaceutical formulations.
📊
Key Findings & Data:These methods are based on the electrochemical oxidation of dopamine at a platinum electrode in an acetonitrile medium containing 0.1 M LiClO₄, where a clear oxidation peak appears at approximately 1.13 V.
💡
Conclusion & Impact:Overall, the proposed methods are accurate, precise, and practical for the determination of dopamine in Dopadren solution and may also be applied to other pharmaceutical formulations.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Dopamine · Voltammetry · Validation

Abstract

The aim of this study was to develop and validate simple, fast, and reliable electrochemical techniques including cyclic voltammetry, linear sweep voltammetry, square wave voltammetry, and differential pulse voltammetry for the determination of dopamine in pharmaceutical formulations. These methods are based on the electrochemical oxidation of dopamine at a platinum electrode in an acetonitrile medium containing 0.1 M LiClO₄, where a clear oxidation peak appears at approximately 1.13 V. The calibration curves showed strong linearity within the concentration range of 10 to 60 µg/mL for the linear sweep, square wave, and differential pulse voltammetry methods. The precision of the methods was acceptable, with intraday and interday relative standard deviation values below 3.12%, while the accuracy was confirmed by relative error values not exceeding 4.78%. The limits of detection were found to be between 1.20 and 1.60 µg/mL, and the limits of quantification ranged from 3.60 to 4.80 µg/mL. Recovery studies indicated an average dopamine recovery of 99.9% in pharmaceutical products, and no significant interference from common tablet excipients was observed under the selected conditions. Overall, the proposed methods are accurate, precise, and practical for the determination of dopamine in Dopadren solution and may also be applied to other pharmaceutical formulations.

🔖

Cite This Article

Yılmaz, B., Bayrak, B., Kadıoglu, Y. (2026). Voltammetric Determination of Dopamine in Pharmaceutical Preparations Using a Platinum Electrode. NanoEra, Volume: 6 Issue: 1. https://ajindex.com/articles/1627646

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (21)

  1. Beaulieu JM, Gainetdinov RR. The Physiology, Signaling, and Pharmacology of Dopamine Receptors. Pharmacol Rev. 2011;63(1):182-217. doi:10.1124/pr.110.002642
  2. Eisenhofer G, Kopin IJ, Goldstein DS. Catecholamine Metabolism: A Contemporary View with Implications for Physiology and Medicine. Pharmacol Rev. 2004;56(3):331-349. doi:10.1124/pr.56.3.1
  3. Missale C, Nash SR, Robinson SW, Jaber M, Caron MG. Dopamine Receptors: From Structure to Function. Physiol Rev. 1998;78(1):189-225. doi:10.1152/physrev.1998.78.1.189
  4. Avan AA, Filik H. Electrochemical Determination of Dopamine Using a Graphene–Screen-Printed Carbon Electrode with Magnetic Solid-Phase Microextraction. Anal Lett. 2018;51(16):2628-2644. doi:10.1080/00032719.2018.1437624
  5. Han C, Wang Q, Yao Y, et al. Thin layer chromatography coupled with surface enhanced Raman scattering for rapid separation and on-site detection of multi-components. J Chromatogr A. 2023;1706:464217. doi:10.1016/j.chroma.2023.464217
  6. El‐Beqqali A, Kussak A, Abdel‐Rehim M. Determination of dopamine and serotonin in human urine samples utilizing microextraction online with liquid chromatography/electrospray tandem mass spectrometry. J Sep Sci. 2007;30(3):421-424. doi:10.1002/jssc.200600369
  7. Wang Y, Li Y, Tang L, Lu J, Li J. Application of graphene-modified electrode for selective detection of dopamine. Electrochem commun. 2009;11(4):889-892. doi:10.1016/j.elecom.2009.02.013
  8. Gao F, Cai X, Wang X, et al. Highly sensitive and selective detection of dopamine in the presence of ascorbic acid at graphene oxide modified electrode. Sensors Actuators B Chem. 2013;186:380-387. doi:10.1016/j.snb.2013.06.020
  9. Honeychurch KC, Brooks J, Hart JP. Development of a voltammetric assay, using screen-printed electrodes, for clonazepam and its application to beverage and serum samples. Talanta. 2016;147:510-515. doi:10.1016/j.talanta.2015.10.032
  10. Wang J. Analytical Electrochemistry. Wiley; 2006. doi:10.1002/0471790303
  11. Brett CMA, Brett AMO. Electrochemistry: Principles, Methods, and Applications. Oxford University Press; 1993.
  12. Paleček E, Bartošík M. Electrochemistry of Nucleic Acids. Chem Rev. 2012;112(6):3427-3481. doi:10.1021/cr200303p
  13. Korkmaz S, Mulazimoglu IE, Demir Mulazimoglu A. Electrochemical Determination of Dopamine in Synthetic Urine Using an Adenine (AD) Modified Pencil Graphite Electrode (PGE). Anal Lett. 2025;58(17):2897-2912. doi:10.1080/00032719.2024.2446957
  14. Yilmaz B, Ekinci D. Voltammetric behavior of carvedilol in non-aqueous media and its analytical determination in pharmaceutical preparations. Rev Anal Chem. 2011;30(3-4):187-193. doi:10.1515/REVAC.2011.106
  15. European Agency for the Evaluation of Medicinal Products. ICH Topic Q2B Note for Guideline on Validation of Analytical Procedures: Methodology (GPMP/ICH/281/95).; 1996.
  16. Laviron E. The use of linear potential sweep voltammetry and of a.c. voltammetry for the study of the surface electrochemical reaction of strongly adsorbed systems and of redox modified electrodes. J Electroanal Chem Interfacial Electrochem. 1979;100(1-2):263-270. doi:10.1016/S0022-0728(79)80167-9
  17. Bard AJ, Faulkner LR. Electrochemical Methods: Fundamentals and Applications. 2nd ed. Wiley; 2011.
  18. Peltola E, Sainio S, Holt KB, Palomäki T, Koskinen J, Laurila T. Electrochemical Fouling of Dopamine and Recovery of Carbon Electrodes. Anal Chem. 2018;90(2):1408-1416. doi:10.1021/acs.analchem.7b04793
  19. Wang CY, Wang ZX, Zhu AP, Hu XY. Voltammetric Determination of Dopamine in Human Serum with Amphiphilic Chitosan Modified Glassy Carbon Electrode. Sensors. 2006;6(11):1523-1536. doi:10.3390/s6111523
  20. Chen X, Chen J, Dong H, Yu Q, Zhang S, Chen H. Sensitive detection of dopamine using a platinum microelectrode modified by reduced graphene oxide and gold nanoparticles. J Electroanal Chem. 2019;848(1-2):113244. doi:10.1016/j.jelechem.2019.113244
  21. Reddy S, Kumara Swamy BE, Jayadevappa H. CuO nanoparticle sensor for the electrochemical determination of dopamine. Electrochim Acta. 2012;61:78-86. doi:10.1016/j.electacta.2011.11.091